Quantum and Evolution Series Installation and Operating Handbook
7-26
Options:
Ignore CRC
Specifies that the terrestrial G.732 frame does not contain a checksum
or
it should be ignored.
Check CRC
Specifies that the terrestrial G.732 frame does contain a checksum that
should be checked for errors. If enough errors accumulate then a Tx Drop
MUX BER alarm will be raised (
‘Input BER > 1E-3’
).
Factory
default:
Ignore CRC
Description:
This option is applicable only with G.732 Drop/Insert bearers and
controls the processing of any terrestrial checksum.
Edit-Tx-Baseband-Advanced-Framing-CRC-Frame Re-acquisition Screen
Frame re-acquisition on CRC loss:
[Normal]
New: Normal