Tab.6
Counters at user / basic installer level
Code
Display text
Description
Range
Subme
nu
AC001
Hours on mains
Number of hours that the appliance has
been on mains power
0 Hours - 4294967295 Hours
System
Function
ality
4.3.2
SCB-09 expansion PCB signals
Tab.7
Navigation for user / basic installer level
Display Level
Menu path
User
> SCB-09
Basic installer
> Installation Setup > SCB-09 > Submenu
> Parameters, counters, signals > Signals
(1) See the column "Submenu" in the following table for the correct navigation. The signals are grouped in specific functionalities.
Tab.8
Signals at user / basic installer level
Code
Display text
Description
Range
Subme
nu
AM004
Blocking code
The current blocking code
0 - 255
System
Function
ality
AM005
Locking code
The currently active locking code.
0 - 255
System
Function
ality
AM012
Status Appliance
Current main status of the appliance.
See
System
Function
ality
AM014
Sub status
Appliance
Current sub status of the appliance.
See
System
Function
ality
4.3.3
Status and sub-status
Tab.9
AM012 - Status
Rang
e
Status
Explanation
0
Standby
The appliance is in standby mode.
1
Heat Demand
A heat demand is active.
2
Generator start
The appliance starts.
3
Generator CH
The appliance is active for central heating.
4
Generator DHW
The appliance is active for domestic hot water.
5
Generator stop
The appliance has stopped.
6
Pump Post Run
The pump is active after the appliance stopped.
8
Controlled Stop
The appliance does not start because the starting
conditions are not met.
9
Blocking Mode
A blocking mode is active.
10
Locking Mode
A locking mode is active.
11
Load test min
Low load test mode for central heating is active.
12
Load test CH max
Full load test mode for central heating is active.
13
Load test DHW max
Full load test mode for domestic hot water is active.
en
4 Settings
8
THIT9650_V1.0_0221 (7710388-03)