CONNECTING THE BATTERIES
(QUALIFIED SERVICE PERSONNEL ONLY)
Please read all of the WARNINGS and CAUTIONS before attempting to con-
nect the batteries.
1. Remove the UPS from the shipping box and set on the floor or a bench top.
2. Remove the front panel retaining screws on the bottom side of the front
panel. (FIG. 1)
3. Slide the front panel downward, then outward, and then move it to the side.
4. Verify proper polarity. Connect the battery positive (red) wire to the battery
positive (red) terminal. (FIG. 2)
NOTE: Some sparking might occur, this is normal.
5. Re-install the front panel onto the UPS.
6. Re-install the front panel retaining screws.
7. Continue with the rest of the Installation.
INSTALLATION
Be sure to read the installation placement and all the cautions before installing
the UPS. Place the UPS in the final desired location and complete the rest of
the installation procedure. These UPSs are shipped with the internal batteries
disconnected. The batteries must be connected before putting these UPSs into
service. See Connecting the Batteries to connect the batteries.
INSTALLATION PLACEMENT
This UPS series is only intended to be install in an indoor temperature con-
trolled environment that is free of conductive contaminants. DO NOT operate
the UPS in: extremely dusty and/or unclean areas, locations near heating de-
vices, water or excessive humidity, or where the UPS is exposed to direct
sunlight. Select a location, which will provide good air circulation for the UPS at
all times.
Route power cords so they cannot be walked on or damaged.
Typi-
cal battery life is 3 to 5 years. Environmental factors do affect battery life. High
temperatures, poor utility power, and frequent, short duration discharges have a
negative impact on battery life.
FIG. 1
FIG. 2
CONNECTING YOUR EQUIPMENT
Plug the mission critical equipment into the Battery Backup & Surge output
receptacles on the rear panel of the UPS. Plug the non-critical equipment into
the Surge Only output receptacles on the rear panel of the UPS. Ensure that
the connected equipment does not exceed the maximum output rating of the
UPS (refer to the information label on the UPS or the electrical specifications in
this manual). DO NOT PLUG EXTENSION CORDS, ADAPTER PLUGS, SURGE
STRIPS OR POWER STRIPS INTO THE OUTPUT RECEPTACLES OF THE
UPS. NOTE: Risk of damaging the UPS and/or connected equipment.
CONNECTING THE UPS TO AN AC SOURCE
CAUTION - To reduce the risk of fire, connect only to a circuit provided with 20
amperes maximum branch circuit over-current protection in accordance with
the National Electric Code, ANSI/NFPA 70. Plug the UPS into a two pole, three
wire, grounded receptacle only. DO NOT PLUG THE UPS INTO EXTENSION
CORDS, ADAPTER PLUGS, SURGE STRIPS OR POWER STRIPS. DO NOT
CUT THE INPUT PLUG OFF AND ATTEMPT TO HARDWIRE THIS UPS, DO-
ING SO WILL VOID THE WARRANTY.
CAUTION! DO NOT connect a laser printer to the output of the UPS.