background image

OWNER’S MANUAL

UNINTERRUPTIBLE POWER SUPPLIES

MODELS DESCRIBED IN THIS MANUAL:

MM250XL/ 1           (120VAC, 60HZ, 250 WATTS)
MM250XL/2            (230VAC, 50HZ, 250 WATTS
MM500/ 1                (120VAC, 60HZ, 500 WATTS)
MM500/2                 (230VAC, 50HZ, 500 WATTS)

MINUTEMAN Uninterruptible Power Supplies are manufactured by Para Systems, Inc. Each unit is fully automatic, simple
to use and designed to be maintenance-free operation for years to come. Each unit provides superior power protection for

all sensitive electronic equipment.

IMPORTANT SAFETY INSTRUCTIONS THAT SHOULD BE FOLLOWED DURING INSTALLATION AND

MAINTENANCE OF THE UPS AND BATTERIES ARE CONTAINED IN THIS MANUAL. SAVE THESE INSTRUCTIONS.

Содержание MM250XL/ 1

Страница 1: ...ruptible Power Supplies are manufactured by Para Systems Inc Each unit is fully automatic simple to use and designed to be maintenance free operation for years to come Each unit provides superior powe...

Страница 2: ...n 2 6 Determining Load Requirements for Selection of the Proper MINUTEMAN Unit 2 7 Installation and Test 3 8 Operation 4 9 Special Features Operation 5 10 System Batteries 5 11 Battery System Checkout...

Страница 3: ...mage is found save both the shipping container and the packing foam in case the unit may later need to be returned to the factory or shipped to another location WARRANTY REGISTRATION Locate your warra...

Страница 4: ...n and off rapidly and repeatedly while the unit is running in the inverter mode battery operation Damage to the MINUTEMAN inverter and your system can occur Do not cover unit air holes or restrict air...

Страница 5: ...D C breaker switch located on the back left bottom of the unit with a red green polarity light above the rear access panel cover MM250XL does not have the polarity light since it is not normally used...

Страница 6: ...seconds the unit returns to the AC Normal mode green light comes back on alarm and amber light goes off Your MINUTEMAN unit is now properly installed and ready to protect your system OPERATION When a...

Страница 7: ...it output becomes overloaded in the inverter mode battery operation circuitry is provided to protect the unit inverter and transformer as well as your system When an overload occurs the MINUTEMAN inve...

Страница 8: ...2 minute warning mode the batteries should be replaced UPS MONITORING CONFIGURATIONS MM500 units in this manual provide a UPS monitoring capability option which will allow direct interface with many d...

Страница 9: ...ailable for new installations which do not already have an add on monitoring board Software sold separately by Sutton Designs Ithaca NY Software sold separately by GNJ Corp Silver Springs MD MINUTEMAN...

Страница 10: ...low Blow MSL3 MM250XL 2 1 5 Amp 250VAC Slow Blow MSL1 5 MM500 1 6 Amp 250VAC Slow Blow MSL6 MM500 2 3 Amp 250VAC Slow Blow MSL3 2 PROBLEM Unit drops load in inverter mode battery operation Probable ca...

Страница 11: ...harges inside the carton or packing list folder Also include your current address for product return 5 Return the unit freight prepaid to Para Systems headquarters at the address shown on the front of...

Страница 12: ...INDIRECT INCIDENTAL CONSEQUENTIAL OR OTHER TYPES OR DAMAGES RESULTING FROM THE USE OF THIS PRODUCT OTHER THAN THE LIABILITY STATED ABOVE THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR I...

Отзывы: