772231901
Service and Support
For service and support during or after installation,
contact the PAR phone center at 1-800-382-6200.
Battery Warning
A lithium coin-type battery is installed on the ES500
motherboard. If this battery is replaced, it must be replaced
with an equivalent battery type. Dispose of the used battery
according to local disposal instructions.
Connect AC Power Cord to
Terminal
1.
Lay the terminal on its back on a clean, flat
surface.
2.
Locate the AC power cord.
3.
Connect the AC power cord to the POS
terminal power supply. The power supply is on
the underside of the terminal.
4.
Connect the other end of the AC power cord
to an uninterruptible power supply (UPS)
Connect Peripherals to POS Terminal
1. Lay the terminal on the counter on its back
with the bottom facing you.
2. Tilt the top cover up.
3. Connect your peripherals to the POS terminal.
Refer to the Cable Connections diagram.
4. Place register upright.
5. Power on the POS terminal. The power button
is located on the bottom left side of the top
cover.
6. Power on the peripherals.
Plug Power Cord into
Power Brick
Cable Connections
CD1= RJ-12 Cash
Drawer Port
LAN Connection
USB Ports
COM 1 COM2
(Connect C8200
Cable)
VGA
Power
Button
Input/Output Connections
M5100:
Two RJ-50 10-pin Serial Ports (COM 1 & 2)
Two RJ-50 Serial Ports available with +12 or 5V
(COM 3 & 4)
One RJ-12 Cash Drawer port
Four (4) Standard 2.0 USB ports
One 10/100/1000 Ethernet Network port
One VGA port for optional second play
One +19V DC power input jack
(Connect C8200 Cable)