![Pantheon PD1 Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/pantheon/pd1/pd1_operating-manual_752329011.webp)
page- 11
Operating Manual PD1/PD2/PD3
2022 rev. 6.0
12
Problem solving
The machine is designed and manufactured for a specific severe environments
and tasks. Its filter, seals, attachments, and fittings are customized or selected
specifically for the applications. Please note that the machine must be
protected from knocks and blows. The operator and service personnel must
treat the machine with care for it to work correctly for an expected life span.
problem
cause
solution
Motor fails to start
No power
Check power supply.
Make sure power cable and
plugs are in a good condition
and properly connected,
Check the power switch is in a
good condition and properly
connected.
Motor stops shortly
after start
Wrong fuse
Connect to a correct fuse
Shortcut in
cable/machine
Order service
Motor runs but with
no suction
Hose not connected
Connect hose
Hose clogged or
blocked
Clean hose
No dust collection
bag
Fit dust collection system
Motor runs but with
a poor suction
Hole in hose
Replace hose
Filter clogged
Clean filter or replace filter
Loose top cover
Make an adjustment of hooks or
top cover
Defective seals or
gaskets
Replace defective seals or
gaskets
Dust leaks out
Hole in hose
Replace the defective hose
Damaged filter
Replace the damaged filter
Poor assembled filters
Make an adjustment of the
poorly assembled filters
Machine works
noisy or abnormal
various causes
Consult the technical support
agent or order a service
Содержание PD1