Panphonics AA-160 Скачать руководство пользователя страница 2

 

 

 

Sound Shower AA-160e / AA-160mm Operation Manual v.2.0 26.3.2012 © 
Panphonics Oy 

 

2/7 

 

ip   update   

Take   new   ip   settings   in   use.   After   ”ip   update”   a   new   connection   must   be   made   and   settings   saved   
by   issuing   ”save   setup”.   If   the   new   settings   are   not   saved   after   ”ip   update”   the   unit   will   
reboot   after   about   5   minutes   and   return   back   to   the   old   settings.   
Usage:   ip   update   
Output:   NA   
   

ip   password   

Change   password   of   the   ip   connection.   New   password   must   be   repeated   twice   after   the   command,   
passwords   are   to   be   separated   by   a   space   character.   The   default   password   is   'passu'.   Maximum   
length   of   the   password   is   16   characters.   
Usage:   ip   password   passu   passu   
Output:   OK   

Changing standby mode ON/OFF 

The amplifier standby mode can be chanced remotely using ‘PWRON’ / ‘PWROFF’ –
commands. The current status can be checked by using ‘STATUS’ command. 
 

STATUS   

Amplifier   status   query,   returns   ON/OFF   depending   on   the   amplifier   state   
Usage:   STATUS   
Output:   STATUS24,OFF   
   

PWRON   

Amplifier   power   on   command   
Usage:   PWRON   
Output:   STATUS03,ON   
   

PWROFF   

Amplifier   power   off   command   
Usage:   PWROFF   
Output:   STATUS49,OFF   

Selecting Input  

The input interface can be selected using the ‘input’ –command. The default input is 
RCA. 
 

input   x   

Select   audio   input:   'input   xlr',   'input   rca'   
Usage:   input   rca   
Output:   OK   

Adjusting Volume 

The current volume setting can be checked with ‘VOLREAD’ –command. The volume 
can be changed by commanding ‘VOL00‘– ‘VOL37’. The minimum is ‘VOL00’ and the 
maximum is ‘VOL37’. Any value between the 00 and 37 can be given. If the setting 
should be permanent (even during the power failure), use the ‘VOLSAVE’ –command 
to save the setting. 
 

VOLREAD   

Read   current   volume   setting   from   the   unit   
Usage:   VOLREAD   
Output:   VOL=22   
   

VOLxx   

Set   volume   VOL00-­‐VOL37   
Usage:   VOL15   
Output:   STATUS00,ON   

 

VOLSAVE   

Save   volume   setting   to   Flash   memory   
Usage:   VOLSAVE   
Output:   OK   

Содержание AA-160

Страница 1: ...If Mac OS X terminal telnet client is used the password might be asked twice because of the echoing defaults ip Print current IP settings Usage ip Output IP 192 168 1 111 255 255 255 0 GW 192 168 1 1...

Страница 2: ...using STATUS command STATUS Amplifier status query returns ON OFF depending on the amplifier state Usage STATUS Output STATUS24 OFF PWRON Amplifier power on command Usage PWRON Output STATUS03 ON PWR...

Страница 3: ...Automatic Volume Control feature activates is automatically set during the standard calibration procedure In some circumstances the automatic base level setting will not give the optimal results It is...

Страница 4: ...can be changed by commanding PRE00 PRE20 The minimum is PRE00 which corresponds the amplitude 1 1 and the maximum is VOL20 and it corresponds 20dB amplitude Changing the PRE setting affects to the act...

Страница 5: ...t IP 192 168 1 111 255 255 255 0 GW 192 168 1 1 ip x x x x Change current IP address use IP address 0 0 0 0 for DHCP The new value does not take effect until ip update command is sent After ip update...

Страница 6: ...e password is 16 characters Usage ip password passu passu Output OK mac Return MAC number of the unit Usage mac Output MAC 0 4 a3 34 f5 ac amb calibrate Run calibration routine for ambient control Usa...

Страница 7: ...nphonics Oy 7 7 Output OK PREREAD Read current volume setting from the unit Usage PREREAD Output PRE 22 PRExx Set input sensitivity PRE00 VOL37 default 10 Usage VOL15 Output STATUS00 ON PRESAVE Save i...

Отзывы: