Sound Shower AA-160e / AA-160mm Operation Manual v.2.0 26.3.2012 © 
Panphonics Oy 

 

1/7 

 

Panphonics AA-160e / AA-160mm amplifier 

Remote Control (for advanced users) 

 
AA-160 series amplifier can be connected into the standard Local Area Network (LAN) 
for controlling the parameters of the AA-160 series amplifier remotely. For handling 
these features some networking experience is required. If you are connecting the 
device into an already existing Network, please consult the Network administrator at 
the first place. 
 
 The remote control from the Network makes it possible to adjust the volume or put 
the amplifier into the standby mode or back into the operation. There are also a 
great number of sophisticated commands for adjusting the Automatic Volume Control 
–algorithm or chance the input sensitivity. The full command reference is at the end 
of this manual. 

Opening the Remote Connection 

For TCP/IP control a telnet connection should be used. The default IP address of the 
unit is 192.168.1.111. and network mask is ‘255.255.255.0’ The default Telnet 
password is ‘passu’*. The device’s IP address can be configured by using the following 
commands. 
 

*If Mac OS X terminal telnet client is used, the password might be asked twice because of the echoing defaults 

 

ip   

Print   current   IP   settings   
Usage:   ip   
Output:   IP   192.168.1.111   /   255.255.255.0   GW=192.168.1.1   
   

ip   x.x.x.x   

Change   current   IP   address,   use   IP   address   0.0.0.0   for   DHCP.   The   new   value   does   not   take   effect   
until   ”ip   update”   command   is   sent.   After   ”ip   update”   a   new   connection   must   be   made   and   settings   
saved   by   issuing   ”save   setup”.   If   the   new   settings   are   not   saved   after   ”ip   update”   the   unit   will   
reboot   after   about   5   minutes   and   return   back   to   the   old   settings.   
Usage:   ip   192.168.1.111   
Output:   OK   
   

ip   mask   y.y.y.y   

Change   current   subnet   mask   settings.   The   new   value   does   not   take   effect   until   ”ip   update”   
command   is   sent.   After   ”ip   update”   a   new   connection   must   be   made   and   settings   saved   by   issuing   
”save   setup”.   If   the   new   settings   are   not   saved   after   ”ip   update”   the   unit   will   reboot   after   
about   5   minutes   and   return   back   to   the   old   settings.   
Usage:   ip   mask   255.255.255.0   
Output:   OK   
   

ip   gw   z.z.z.z   

Change   current   gateway   settings.   The   new   value   does   not   take   effect   until   ”ip   update”   command   is   
sent.   After   ”ip   update”   a   new   connection   must   be   made   and   settings   saved   by   issuing   ”save   
setup”.   If   the   new   settings   are   not   saved   after   ”ip   update”   the   unit   will   reboot   after   about   5   
minutes   and   return   back   to   the   old   settings.   
Usage:   ip   gw   192.168.1.1   
Output:   OK   
   

Содержание AA-160

Страница 1: ...If Mac OS X terminal telnet client is used the password might be asked twice because of the echoing defaults ip Print current IP settings Usage ip Output IP 192 168 1 111 255 255 255 0 GW 192 168 1 1...

Страница 2: ...using STATUS command STATUS Amplifier status query returns ON OFF depending on the amplifier state Usage STATUS Output STATUS24 OFF PWRON Amplifier power on command Usage PWRON Output STATUS03 ON PWR...

Страница 3: ...Automatic Volume Control feature activates is automatically set during the standard calibration procedure In some circumstances the automatic base level setting will not give the optimal results It is...

Страница 4: ...can be changed by commanding PRE00 PRE20 The minimum is PRE00 which corresponds the amplitude 1 1 and the maximum is VOL20 and it corresponds 20dB amplitude Changing the PRE setting affects to the act...

Страница 5: ...t IP 192 168 1 111 255 255 255 0 GW 192 168 1 1 ip x x x x Change current IP address use IP address 0 0 0 0 for DHCP The new value does not take effect until ip update command is sent After ip update...

Страница 6: ...e password is 16 characters Usage ip password passu passu Output OK mac Return MAC number of the unit Usage mac Output MAC 0 4 a3 34 f5 ac amb calibrate Run calibration routine for ambient control Usa...

Страница 7: ...nphonics Oy 7 7 Output OK PREREAD Read current volume setting from the unit Usage PREREAD Output PRE 22 PRExx Set input sensitivity PRE00 VOL37 default 10 Usage VOL15 Output STATUS00 ON PRESAVE Save i...

Отзывы: