Revision 1.1 April 20, 2016
1
Panoramic Power System
PAN-14 User Guide
(P/Ns PAN-14-US, PAN-14-EU)
Страница 1: ...Revision 1 1 April 20 2016 1 Panoramic Power System PAN 14 User Guide P Ns PAN 14 US PAN 14 EU...
Страница 2: ...erified by turning the device off and on the user is encouraged to eliminate the interference by one or more of the following measures Re orient or re locate the receiving antenna Increase the distanc...
Страница 3: ...r customers with recycle responsibilities Disposal of electrical and electronic products must be done according with the local and national regulations You can return your product to a local collectio...
Страница 4: ...he Hardware 6 Safety Precautions 6 Mapping the Site 6 Installing the Sensor 7 Registering the Installed Sensor 9 Monitoring Sensor Activity 9 Uninstalling a Sensor 9 Sensor Specifications 9 Range of R...
Страница 5: ...t Sensor Current Transformer CT Workflow Sensor installation consists of the following steps 1 Map the circuits See Panoramic Power Deployment Tool User Guide 2 Physically attach the sensors and the C...
Страница 6: ...ower supply to the panel must be shut off before and during installation The sensor and CT must not be installed lying or touching bus bars or any other non insulated exposed conductors Installation i...
Страница 7: ...or to the CT 2 Connect the two CT s outputs to the PAN 14 sensor using a 1 0 4 0mm2 12 17 AWG wires as follows a Connect the PAN 14 sensor s terminal marked as 1 to the CT s terminal marked as S1 or X...
Страница 8: ...the sensor Place the PAN 14 sensor on the side that is closer to the bridge To avoid RF blocking make sure the CT is not positioned between the sensor and the bridge If possible attach the PAN 14 sens...
Страница 9: ...l dimensions 33 8 29 42 5 mm 1 33 1 14 1 67 inch Current input range from external current transformer 0 5 ARMS up to 10 A peak Current measurement range Any applicable range based on CT ratio Current...
Страница 10: ...030 2010 1st Edition CE EMC EN ETSI 301489 3 Radio EN ETSI 300220 1 World Safety CB Certification by Intertek IEC 61010 1 2010 3rd Edition IEC 61010 2 030 2010 1st Edition Flammability rating of exte...
Страница 11: ...annot be used The following list includes the CTs that were already tested and approved by Panoramic Power Dixsen CTs 600A split model DBP 58 600A non split rectangular model MES 62 1000A split model...
Страница 12: ...e circuit has current Make sure that the sensor arrow points in the direction of the load Make sure that the sensor LED is blinking Make sure the sensors are near enough to the bridge for the bridge t...