Section 1: General Features and Specifications
Installation
Unpacking
Unpack the
RM-2440
unit from the shipping container and inspect all articles for shipping damage. If you find any damage,
notify the shipping carrier immediately for claims adjustments. Compare the shipping box contents to the packing slip. Contact
our PANORAMAdtv sales representative if there are any unexplained shortages.
Cooling and Airflow
No special physical mounting considerations are necessary regarding unit heat dissipation except under adverse conditions. Provided
the ambient temperature inside the mounting enclosure does not exceed 40 degrees Celsius (104 degrees Fahrenheit), adjacent devices
can be rack mounted (or stacked) in proximity to the
RM-2440
unit. If the above temperature is exceeded, allow a 1RU (1.75”/25mm)
space above and below the unit for air circulation.
Rack Mounting
The
RM-2440
unit rack mounts in a standard EIA-310-D specification 19”/483 mm rack and needs only 2RU of space. Allow
sufficient space at the unit rear for connector and cable clearance (approximately 4”/102mm). The
RM-2440
unit rack
mounts from the front panel support rails. Rear support is not required.
See
Figure-2c
on page
12
for
RM-2440
rack, standard connector, and optional
RMSDI
module connector clearance
dimensions.
General Installation Recommendations
Recommended Cables:
Recommended cable type for Composite (analog) or SDI video signals is:
Belden 1694A
(or
equivalent).