Technical datas
Input voltage: 230V~50Hz
Power: 8W
Power in standby mode: <1,0W
Protection IP: IP65
Class of protection: ll.
Lighting source: 18LED
Intensity: 55lm
Autonomy: 3h
Battery: NiCd (3,6V 1200mAh)
Time of recharge: 3-24h
Operating temperature: -5°C~ 40°C
Weight: 470g
Installation
Notice
Before using, check the product and make sure there is no damage,
otherwise do not use it. Before installation make sure that the power
cable is disconnected. In case of damage do not repair or disassemble
the product. If the lamp does not reach the prescribed value of
autonomy, battery must be replaced. Note date of installation in the
operating diary. By connecting battery to the lamp, take notice of
correct polarity. After installation charge the battery to maximum.
Effective life of battery can be lowered by operating at too
low/high temperatures and incorrect way of charging.
LED are not replacable.
Infringement of any instruction mentioned in instruction manual can
cause harm to health or property.
INSTRUCTIONS
MODEL:
LXE-1803-CC
Emergency LED lighting
FENIX
UM_FENIX_110629
Technical data can be changed without previous notice.
All right reserved.
Testing
Testing should be made in a time, when the functionality and purpose of the whole emergency lighting system is affected
minimally.
Testing should be made regularly and in conformity with relevant regulations and laws. Make a note about each test in the
operating diary. During the testing watch the status of LED indicator (recharging of the battery), light source and lamp
autonomy.
1x day: test of the LED indicator, recharging of the battery
1x month: short function test of the battery and lighting source after disconnecting the mains supply.
1x year: full functionality test from battery by the time of autonomy, inspection of the autonomy, inspection of the battery
and light source.
Application
At regular operation lights only LED control light that signals recharging of the battery.
By outage of mains supply the lamp turns ON and stays ON minimally for the time of autonomy or till discharging of the
battery.
After elimination the outage, regular operation will be restored automatically.
The lamp is designed to secure light in case of mains supply outage.
Type LXE-1803-CC is equipped with combined function and may be used as an regular lamp.
1
2
3
4
5
7
230V~50Hz
6
CABLE GLAND
L´ (ACL2)
L (ACL1)
N (ACLN)
264mm
52mm
100mm
200mm