background image

 

 

 

 

                                                               www.panel.it                                                                4 

 

 

 

Chapter 1: Preface 

 

1.1  Safety rules 

 

All the VESA Mount PC PVR series have been designed and built taking into account all the issues associated with an 
industrial  environment  such  as  that  where  it  is  necessary  to  ensure  the  operation  of  the  system  in  the  presence  of 
vibration, moisture, dust and critical heat conditions. 
Only skilled staff must make any job on the device, only after having fully read and understood the safety instructions. 
Before installing and using the device, note the following precautions: 

 

-

 

Read all instructions carefully. 

-

 

Do not place the unit on an unstable surface, cart, or stand. 

-

 

Avoid using the system near water, in direct sunlight, or near a heating device. 

-

 

To prevent electrical shock or equipment damage, unplug the power cord from the power supply prior to 
installing or wiring the PC. 

-

 

Do not disassemble or modify the Panel PC. Doing so may cause a fire or an electric shock. 
All tasks such as the installation, commissioning and servicing of devices are only permitted to be carried out by 
qualified  personnel.  Qualified  personnel  are  those  familiar  with  the  transport,  mounting,  installation, 
commissioning  and  operation  of  devices  who  also  have  the  appropriate  qualifications.  National  accident 
prevention regulations must be observed.  

 

1.2  Product checking

 

 
Preliminary operations to be made as soon as you receive the PANEL product: 
 

-

 

Check if the p

acking hasn’t unde

rgone any damage due to transport. 

-

 

Verify if the packing contents correspond to the delivery note. 

 
The product model, code and serial number are shown on the identification plate which is positioned on the rear. 

 

 

 

If serious damages or inconsistency are found between the packing contents and the delivery note, please contact the 
PANEL SRL sales department immediately. 

It’s advisable 

to keep the original packing in order to use it for possible transports back in assistance

 

 

Содержание PVR-EM Series

Страница 1: ...ieved to be accurate as of the date of publication however Panel S r l makes no warranty ex pressed or implied with regard to the products or documentation contained within this manual Panel S r l res...

Страница 2: ...s 8 2 5 Mechanical dimensions 9 2 6 VESA mounting 10 2 7 Chemicals and solvents resistance 11 Chapter 3 Installation and wiring 3 1 Mounting distance 13 3 2 Connecting DC power 14 3 3 Connecting AC po...

Страница 3: ...el it 3 3 Chapter 6 System setup 6 1 Installing operating system 24 6 2 Bios setup 24 6 3 Touchscreen driver and calibration 24 Chapter 7 Maintenance 7 1 Cleaning 25 7 2 Lithium battery 25 7 3 Spare p...

Страница 4: ...sassemble or modify the Panel PC Doing so may cause a fire or an electric shock All tasks such as the installation commissioning and servicing of devices are only permitted to be carried out by qualif...

Страница 5: ...mplies to the requirements of Low voltage directive 2006 95 EC EMC Directive 2004 108 EC RoHS Directive 2011 65 EU Carries marking EMC EN 55022 2010 Class B EMC EN 55024 2010 Class B LVD EN 60950 1 20...

Страница 6: ...rs or according to PANEL indisputable judgment to the replacement of the product itself The product under warranty must reach our headquarters equipped with the indication of the anomaly found and wit...

Страница 7: ...1 GHz RAM 2x DDRL3 SO DIMM 1866 MHz up to 16 GB I O ports 2x Gigabit LAN 1x HDMI 1x VGA 1x RS232 2x RS232 422 485 4x USB 3 0 2x USB 2 0 1x Line Out 1x Mic in 2x PS 2 ports Expansions 1x Mini PCI E ful...

Страница 8: ...Impact 3 0 mm DIA Steel Ball 9g Height 30 cm Static Load 500g within 10cm2 area for 30 sec Hardness 3H pencil pressure 1N 45 Speeling 800g cm by vertical 90 Reliability High temperature Humidity 70 C...

Страница 9: ...2 5 Mechanical dimensions PVR display units with retaining clips All dimensions are specified in mm Display size Model A B C D E F G H I L 15 0 single touch resistive PVR015 355 280 21 11 5 332 355 6...

Страница 10: ...these screws is 0 7 to 0 8 N m VESA stands for Video Electronics Standards Association an international non profit corporation which represents more than 100 corporate members worldwide and sets indus...

Страница 11: ...ery acid Diacetone Alcohol Dioxan DS2 Decontamination fluid Fabric conditioner Acetonitrile Alkalicarbonate Ammonia 40 Bichromate Blown castor oil Ethylacetate Fluorochlorohydrocarbons Glycerine Glyco...

Страница 12: ...lfuric Acid 5 0 2 Acetic Acid 10 0 10 Ethanol 50 0 10 Methanol 50 0 10 Gasoline 100 0 10 Kerosene 100 0 10 Acetone 100 0 1 Toluene 100 0 1 Solution of salt 3 0 10 Boil Water 100 0 0 25 Detergent Kao M...

Страница 13: ...ntenance operation and improved ventilation be sure to install the PVR away from adjacent structures and other equipment See the following drawings Be sure that the ambient operation temperature and t...

Страница 14: ...VDC input voltage limits 9 36 VDC The DC power cable must be secured in the terminal block power connector as shown in the image Wires with a cross section of 0 75 mm2 to 2 5 mm2 3 3 Connecting AC pow...

Страница 15: ...d to the central grounding point in the control cabinet using the shortest route possible A cable with a minimum cross section of 2 5 mm per connection should be used All data cables connected to the...

Страница 16: ...l PC disconnect the power cable Isolate the system from all potential sources of electrical power Discharge any electrostatic charge on the ground connection 4 2 RAM installation RAM Memory slots Unsc...

Страница 17: ...nent damage to the motherboard and the SO DIMM if you force the SO DIMM into the slot at incorrect orientation Step 2 Firmly insert the SO DIMM into the slot until the retaining clips at both ends ful...

Страница 18: ...d 1 Before installing the expansion card please make sure that the power supply is switched off or the power cord is unplugged Please read the documentation of the expansion card and make necessary ha...

Страница 19: ...rdware settings for the card before you start the installation 2 Remove the system unit cover if your motherboard is already installed in a chassis 3 Remove the bracket facing the slot that you intend...

Страница 20: ...www panel it 20 20 Chapter 5 jumpers and connectors 5 1 Motherboard IMB 156 layout...

Страница 21: ...COM5 PWR_COM6 15 4 Pin Chassis FAN Connector 12V 16 2 Pin Buzzer Header 17 COM4 5 6 Headers RS232 18 Digital Input Output Default Value Setting JGPIO_SET1 19 Backlight Power Select LCD_BLT_VCC BKT_PWR...

Страница 22: ...K Mic in B Supply Connector L PS 2 mouse port C 2x USB 2 0 M RS232 422 485 COM 1 D HDMI N RS232 422 485 COM 3 E PS 2 keyboard port O Gigabit LAN 1 F RS232 422 485 COM 2 P Gigabit LAN 2 G VGA Q Audio O...

Страница 23: ...p to short the pins on CLRMOS2 for 3 seconds Please remember to remove the jumper cap after clearing the CMOS If you need to clear the CMOS when you just finish updating the BIOS you must boot up the...

Страница 24: ...The removal or loss of the authenticity certificate implies the forfeiture of the operating system license contract Using the software without regular license is a legal offence This motherboard suppo...

Страница 25: ...ned with water and detergent a screen cleaning agent or alcohol ethanol The cleaning agent should be applied to the cloth beforehand not sprayed directly on the device Aggressive solvents chemicals sc...

Отзывы: