background image

FOR TECHNICAL SUPPORT www.panduit.com/resources/install_maintain.asp

INSTALLATION INSTRUCTIONS

CM599L

© Panduit Corp. 2016

Page 2 of 27

N

ET

-A

CCESS 

S-Type Server Cabinets

(Server Configurations)

Disclaimer:

The information contained in this manual is intended as a guide for use by persons having technical 
skill at their own discretion and risk.  The recommended practices are based on average conditions.  
Panduit makes no representation or warranty, express or implied, nor assumes any responsibility for 
the accuracy or completeness of these installation instructions.  Panduit does not guarantee any 
favorable results nor assume any liability for damages, improper installation, system failures, or any 
other problems that could arise in connection with the use of these installation instructions.

NOTE:

  Some views in this document may vary 

slightly from your actual cabinet configuration.

Содержание NET-ACCESS S-Type

Страница 1: ...OM SKID CM599L NET ACCESS S Type Server Cabinets Phillips screwdriver Flatblade screwdriver 22mm socket wrench 15mm socket wrench 13mm socket wrench 8mm socket wrench 48 level 7mm socket wrench T30 Torx bit T25 Torx bit 6mm Allen key 2 5mm Allen key Wire cutter TOOL LIST ...

Страница 2: ...sk The recommended practices are based on average conditions Panduit makes no representation or warranty express or implied nor assumes any responsibility for the accuracy or completeness of these installation instructions Panduit does not guarantee any favorable results nor assume any liability for damages improper installation system failures or any other problems that could arise in connection ...

Страница 3: ...Code and the applicable sections of ANSI C2 the National Electrical Safety Code The instruction shall not result in the risk of fire electric shock or injury to persons UL Listing covers enclosure cabinet only IMPORTANT SAFETY INFORMATION CABINET TIPPING HAZARD This cabinet can easily be tipped Use extreme caution when unpacking or moving the cabinet Use at least 2 persons to remove cabinet from p...

Страница 4: ...Cable Management Fingers SN15F SN25F 14 CCL3 Combination Lock Swing Handle Installation 15 Single Hinge Door Removal and Installation 16 Single Hinge Door Door Handle Direction Reversal 17 Rear Split Doors Removal and Installation 18 Side Panel Distinguishing Features also reference instructions V00029CM 19 Hinged Side Panels Removal Installation and Adjustment optional 20 PDU Bracket Adjustment 2...

Страница 5: ... Legs must be fully retracted before the cabinet is moved into place Sliding cabinet on leveling legs may result in damage to the leveling legs Leveling Legs ship in retracted position Packaging Material Removal Shipping Hold Down Bracket Doubles as Floor Mounting Bracket Retain bracket if floor mounting is desired see Page 7 Remove all stretchwrap and protective cardboard from outside of cabinet ...

Страница 6: ...d Slide Cabinet into final position Lower the 4 Leveling Legs until the cabinet weight is fully supported by only the leveling legs Adjust the 4 Leveling Legs so that the cabinet is level front to back and side to side Note When ganging multiple cabinets together ensure that adjacent cabinets are adjusted to the same height 4 Leveling Legs use 6mm Allen Key 6mm Allen Key Clockwise to RAISE cabinet...

Страница 7: ...binet See Floor Mounting View below for floor mounting dimensions 4 M10 Hex Head Screws use 15mm socket wrench Floor Mounting View DIM A 1070mm deep cabinets 726mm 28 58 1200mm deep cabinets 878mm 34 57 4 Shipping Hold Down Brackets DIM B 600mm wide cabinets 191mm 7 52 700mm wide cabinets 241mm 9 48 800mm wide cabinets 291mm 11 46 CABINET TIPPING HAZARD Mount cabinet to floor before equipment is i...

Страница 8: ...s are level Secure Ganging Brackets to cabinets at 2 front locations shown below 2 Front Ganging Brackets 4 M6 Torx Screws use T25 Torx bit FRONT OF CABINETS CABINET TIPPING HAZARD Ganging of cabinets only provides limited stability to the cabinets and is not a substitute for proper leveling or floor mounting of cabinets Ensure that cabinets are properly mounted to floor before equipment is instal...

Страница 9: ... locations shown below Do not use Ganging Brackets to cinch cabinets together Holes for screws are not tapped Apply force to drive screws REAR OF CABINETS 2 Rear Ganging Brackets 4 M5 Torx Screws use T25 Torx bit CABINET TIPPING HAZARD Ganging of cabinets only provides limited stability to the cabinets and is not a substitute for proper leveling or floor mounting of cabinets Ensure that cabinets a...

Страница 10: ...locations Remove factory installed masking tape at grounding lug location to expose unpainted surface of cabinet frame Grounding lug or grounding bar must assembled onto this unpainted surface per NEC NFPA 70 Article 250 12 Use 2 M5 bonding screws to fasten grounding terminal to cabinet frame torque screws to 5 1 N m 45 in lb Note top cap removed for clarity Masking Tape Masking Tape ELECTRICAL SH...

Страница 11: ...to Back Beam REVERSE STEPS to re install Equipment Rails insert Equipment Rail Mount Nuts through slots of Front to Back beam while holding finger grip of mount nut ensure that barbed surface of Equipment Rail Mount Nut faces outside of cabinet TOP AND BOTTOM M10 Hex Head Screw use 15mm socket wrench UNINSTALL RE INSTALL AND MOVE EQUIPMENT RAILS M10 Hex Head Screw use 15mm socket wrench Equipment ...

Страница 12: ...s Zero RU QuickNet Patching Adapter Installation Insert plastic Patching Adapters by snapping adapter into rear facing surface of rear equipment rails Patching Adapters accommodate Panduit QuickNet Copper and Fiber Cabling Systems optional Included on select 600mm wide S Type cabinet configurations Insert Patching Adapters snap into equipment rails ...

Страница 13: ...h wire cutter to open large cable openings OPTIONAL Install M10 threaded rod into 6 tapped holes for 1070mm deep cabinets or 9 tapped holes for 1200mm deep cabinets if desired 2 165 1mm x 165 1mm 6 5 x 6 5 openings can be used to route power overhead PANDUIT COOL BOOTTM products can be used to seal around cables fiber to prevent hot air recirculation 6 M10 Threaded Holes Bezel OPTIONAL use wire cu...

Страница 14: ...asp CM599L Panduit Corp 2016 Page 14 of 27 Cable Management Fingers SN15F SN25F Insert tabs of Cable Management Finger into mounting slots of cabinet post Slide Cable Management Finger inward to lock into place Cable Managment Finger Insert tabs into cabinet post Slide inward to lock in place ...

Страница 15: ...Open swing handle Rotate handle insert counter clockwise 30º from unlocked position or 210º from locked position Set 3 dials to desired combination Return handle insert to original position Close swing handle 3 Dials Handle Insert from unlocked rotate counter clockwise 30º from unlocked position to set new combination Handle Insert from locked rotate counter clockwise 210º from locked position to ...

Страница 16: ...gle Hinge Door Removal and Installation VIEW 1 Pull down Compression Sleeve at top door hinge VIEW 1 Pull Single Hinge Door away from cabinet so that Top Hinge Screw fits through cutout of door VIEW 2 Lift bottom of door off Bottom Hinge Pin Compression Sleeve Pull down Top Hinge Screw Bottom Hinge Pin VIEW 1 VIEW 2 VIEW 3 Plastic Washer ...

Страница 17: ... if necessary VIEW 1 2 Install Top and Bottom Hinge Brackets on opposite side of cabinet re install top hinge screw if necessary VIEW 3 Move Door catch to opposite side of cabinet frame VIEW 4 5 Remove Horizontal Grounding Bracket and reinstall on opposite side of door Door Handle Reversal Lay door on a flat surface VIEW 5 6 Remove Door Handle Backing Plate and rotate position of Door Handle 180º ...

Страница 18: ... com resources install_maintain asp CM599L Panduit Corp 2016 Page 18 of 27 Rear Split Doors Removal and Installation Open Rear Split Doors to approximately 90º Lift Rear Split Doors up pull doors away from cabinet frame REVERSE STEPS to install Rear Split Doors ...

Страница 19: ...RRENT VERSION 2 Adjustable bushings ORIGINAL VERSION No backstop feature on bottom beam ORIGINAL VERSION 2 Plastic bushings ORIGINAL VERSION Overlapping flange on rear side panel outside CURRENT VERSION Overlapping flange on front side panel inside Original Cabinet Current Cabinet S21SPS S22SPS S51SPS S52SPS S81SPS S82SPS S11SPS S12SPS S21SPSE S22SPSE S51SPSE S52SPSE S81SPSE S82SPSE S11SPSE S12SPS...

Страница 20: ... release Front Side Panel from cabinet frame REVERSE STEPS to install In Row Side Panels IMPORTANT Install Front Side Panel First Spring Loaded Hinge Pin Top and Bottom Move Finger Pull into Slot to Lock Hinge Pin in OPEN position Spring Loaded Hinge Pins 2 Locations Front Side Panel Adjust Fit of Side Panels Use included wrench to raise or lower adjustment bushings Rear Side Panel Spring Loaded H...

Страница 21: ...er than the factory position is desired Remove 2 M5 Torx Screws per bracket as shown below Reposition brackets at desired distance ensuring that mounting flange of PDU bracket rests on the outside of cabinet post See Installed view below Secure each PDU bracket to cabinet post with 2 M5 2 M5 Torx Screws use T25 Torx bit PDU Bracket installed Top PDU Bracket Bottom PDU Bracket 2 M5 Torx Screws use ...

Страница 22: ...is desired Remove 4 or 6 M5 Torx Screws from bracket as shown below Reposition bracket at desired height ensuring that mounting flange of bracket rests on the outside of cabinet post Secure bracket to cabinet post with 2 M5 Torx Screws per bracket M5 Torx Screws Use T25 Torx driver DETAIL VIEW Cable Management Panel NOTE Alternate Mounting Holes Primary Mounting Hole Alternate mounting holes are t...

Страница 23: ...016 Page 23 of 27 Cabinet Sealing Install 6 Latch Plugs 3 upper and 3 lower into the door latch cut outs to the front side of the cabinet only Install 2 foam seals to the upper and lower frame Seal should be pressed up against the Equipment Rails behind the latch plugs 3 Latch Plugs 3 Latch Plugs Foam Seal Foam Seal ...

Страница 24: ...p CM599L Panduit Corp 2016 Page 24 of 27 Front and Rear Floor Seal Installation Vertical Exhaust Duct ONLY Install Floor Seal to front or rear of cabinet frame using 2 M10x20mm Bolts Flange on floor seal will face outward away from the cabinet 2 M10x20mm Bolts use 15mm socket wrench Floor Seal ...

Страница 25: ...Manager base using 5 M5x0 8 button head Torx screws use T25 Torx bit Re install screws from previous step to secure to the frame Attach front fascia to the front vertical wall by sliding fascia over studs in vertical wall see detail view Tighten with 4 M5x0 8 button head screws use T25 Torx bit Attach rear fascia to the rear vertical wall by sliding fascia over studs in vertical wall see detail vi...

Страница 26: ...Manager base using 5 M5x0 8 button head Torx screws use T25 Torx bit Re install screws from previous step to secure to the frame Attach front fascia to the front vertical wall by sliding fascia over studs in vertical wall see detail view Tighten with 4 M5x0 8 button head screws Attach rear vertical wall to the Cable Manger with 4 M5x0 8 button head screws use T25 Torx bit from underneath Top of Ca...

Страница 27: ...es and Technical Support www panduit com resources install_maintain asp E mail techsupport panduit com Phone 866 405 6654 www panduit com INSTALLATION INSTRUCTIONS CM599L Panduit Corp 2016 Page 27 of 27 THIS PAGE IS INTENTIONALLY BLANK ...

Отзывы: