background image

© Panduit Corp. 2018 

OPERATION INSTRUCTIONS 

CT-460

 

 

CT-460: PA24481A01_04 

 

 

 

Page: 4 of 4 

 

 

 

 

6-2018 

6. 

If both the GO and NO-GO conditions are met; the tool is dimensionally correct – if either condition fails, 
adjust the DIE CLOSURE as follows: 
 

a. 

Remove lock screw with small wrench [see FIG. 2]. 
 

b. 

With adjustment wrench provided, turn adjustment pin one notch – each notch produces 
approximately .002” of adjustment.  A clockwise turn increases the die closure and a counter-
clockwise turn decreases the die closure. 
 

c. 

Close the tool and plug gage the die closure as instructed above.  If the GO/NO-GO conditions are 
not met, repeat Step (2) in one-notch increments until the tool is gages to be dimensionally correct.  
Replace and tighten both lock screws after final adjustment. 
 

7. 

If the above procedure fails to satisfy all GO and NO-GO conditions, contact your local Panduit Sales 
Office; or contact Technical Support at 1-800-777-3300. 

 
 
 

FIG. 6 

 

POCKET 

SIZE 

CRIMP DIE CLOSURE 

GAGING 

GAGE ELEMENT 

DIAMETERS 

GO 

NO-GO 

GO 

NO-GO 

16-14 BLUE 

0.114 

0.124 

0.1140 - 0.1143 

0.1237 - 0.1240 

12-10 YELLOW 

0.153 

0.163 

0.1530 - 0.1533 

0.1627 - 0.1630 

 

 
 

POCKET 

SIZE 

INSULATION DIE CLOSURE 

GAGING 

GAGE ELEMENT 

DIAMETERS 

GO 

NO-GO 

GO 

NO-GO 

16-14 BLUE 

0.142 

0.158 

0.1420 - 0.1423 

0.1577 - 0.1580 

12-10 YELLOW 

0.195 

0.211 

0.195 - 0.1953 

0.2107 - 0.2110 

 
 
 
 
 
 

Отзывы: