© Panduit Corp. 2018
OPERATION INSTRUCTIONS
CT-460
CT-460: PA24481A01_04
Page: 4 of 4
6-2018
6.
If both the GO and NO-GO conditions are met; the tool is dimensionally correct – if either condition fails,
adjust the DIE CLOSURE as follows:
a.
Remove lock screw with small wrench [see FIG. 2].
b.
With adjustment wrench provided, turn adjustment pin one notch – each notch produces
approximately .002” of adjustment. A clockwise turn increases the die closure and a counter-
clockwise turn decreases the die closure.
c.
Close the tool and plug gage the die closure as instructed above. If the GO/NO-GO conditions are
not met, repeat Step (2) in one-notch increments until the tool is gages to be dimensionally correct.
Replace and tighten both lock screws after final adjustment.
7.
If the above procedure fails to satisfy all GO and NO-GO conditions, contact your local Panduit Sales
Office; or contact Technical Support at 1-800-777-3300.
FIG. 6
SIZE
CRIMP DIE CLOSURE
GAGING
GAGE ELEMENT
DIAMETERS
GO
NO-GO
GO
NO-GO
16-14 BLUE
0.114
0.124
0.1140 - 0.1143
0.1237 - 0.1240
12-10 YELLOW
0.153
0.163
0.1530 - 0.1533
0.1627 - 0.1630
SIZE
INSULATION DIE CLOSURE
GAGING
GAGE ELEMENT
DIAMETERS
GO
NO-GO
GO
NO-GO
16-14 BLUE
0.142
0.158
0.1420 - 0.1423
0.1577 - 0.1580
12-10 YELLOW
0.195
0.211
0.195 - 0.1953
0.2107 - 0.2110