AT-UHD-CLSO-601
29
TrigCEC
Sends the specified command to the display using CEC. The output must always be specified and set to the value
of
1
. Do not add a space between the command and the first argument.
Example
TrigCEC1 on
Syntax
TrigCECX Y
Parameter
Description
Range
X
Zone
1
Y
Command
on, off
Feedback
TrigCEC1 on
Commands
TrigIP
Sends the specified command to the display using IP. Do not add a space between the command and the first
argument.
Example
TrigIP1 on
Syntax
TrigIPX Y
Parameter
Description
Range
X
TCP
1, 2
Y
Command
on, off, vol+, vol-, mute
Feedback
TrigIP1 on
TrigRS
Sends the specified command to the display using RS-232. The output must always be specified and set to the
value of
1
. Do not add a space between the command and the first argument.
Example
TrigRS1 on
Feedback
TrigRS1 on
Syntax
TrigRSX Y
Parameter
Description
Range
X
Zone
1
Y
Power state
on, off, vol+, vol-, mute