Pandora VS-23d Скачать руководство пользователя страница 2

Mounting instruction

Microwave sensor should be installed inside of the car interior in places that provide uniform 

sensitivity across the interior space (generally, between front seats of a car, under torpedo, less in the 

lamp cover).

0

-180

-90

-60

-30

30

150

-150

120

-120

90

60

0

-180

-90

-60

-30

30

150

-150

120

-120

90

60

Diagram orientation in the horizontal plane*

Diagram orientation in the vertical plane*

* d

iagram orientation of the sensor is approximate, in real conditions sensitivity depends on the vehicle and the sensor mounting location

Adjusting sensor sensitivity

Sensitivity of microwave sensor VS-23d zones (warning/alarm) should be set sequentially (in any order). 

Sensitivity of sensor alarm triggering zone cannot be more than sensitivity of warning zone.

When selecting the place to install the sensor, pay attention that nearby metal objects and elements of 

the car body reduce the sensor sensitivity and change the diagram orientation. The sensor can be 

connected to the system base unit with the cable that is in the system set.

1. Entering settings mode
Press and hold SETUP button for 2 seconds.
LED indicators flashes red and green in rotation.

2. Adjusting warning level
Press + button of 1-st SENS to increase or - button of 1-st SENS to decrease sensitivity. Hold the button 

for prompt sensitivity setting.
LED indicator displays the current sensitivity value. Frequency of indicator flashing equals sensitivity: 

when maximum sensitivity - LED indicator lights almost continuously, when minimum sensitivity - it 

flashes occasionally.
- The sensor proceeds to the mode of displaying active zones in 3 seconds that is indicated with single 

flash of two LED indicators simultaneously.

3. Adjusting alarm level
Press + button of 2-st SENS to increase or - button of 2-st SENS to decrease sensitivity. Hold the button 

for prompt sensitivity setting.
LED indicator displays the current sensitivity value. Frequency of indicator flashing equals sensitivity: 

when maximum sensitivity - LED indicator lights almost continuously, when minimum sensitivity - it 

flashes occasionally.
The sensor proceeds to the mode of displaying active zones in 3 seconds that is indicated with single 

flash of two LED indicators simultaneously.

4. Exit and save settings
To save sensitivity value and exit settings mode, press and hold SETUP button for 2 seconds.
LED indicators flashes red and green 3 times simultaneously.

If some buttons were not pressed for 1 minute, this mode will be exited automatically.

Specifications

Supply voltage range.................................................. 9...16V 

Current consumption when arming...................... no more than 1,8 mA 

Output circuits type..................................................... open drain n-chanel MOSFET 

Output signals duration:

   warning......................................................................... no less than 0,5 sec.

   alarm.............................................................................. no less than 0,5 sec.

Dimensions..................................................................... 71,5x42x11,5 mm

Operating temperature range.................................. - 40°С ... +85°С

System set

Microwave sensor VS-23d............. 1

Interface cable................................... 1

User installation manual................ 1