background image

EN

- 31 -

• For models and versions supplied with external, ceiling or wall-mounted motors, where the motor is to 
be located must be taken into account, as it must be in an easily-accessible, safe place with enough room 
for the size of motor for any possible repair or maintenance work by the technical service.

• Once the motor required has been decided on, take into account the maximum distance between the 
hood and the motor according to the table of motor features.

• For high-powered motor systems, V2300 and V2500, the minimum distance from hood to motor must 
be 4m, or preferably between 4 and 6m. If they are located closer together, this may create problems with 
high noise levels. It is also advisable to install motors of this type with a SEC soundproof flue (optional, 
not included as standard; consult distributor).

• The cooking area must be centred underneath the hood, and must always be smaller than the hood, i.e. 
the hood must project further than the cooking area by at least 10cm on each side.

COMPATIBILITY WITH THE HEATING POWER OF COOKING AREAS

• Our hoods are for domestic use and are designed to withstand  a heating power of up to 3.6Kw in the 
cooking area. Do not use with professional or wood-burning cookers.

• If burners with heating power in excess of 3.6Kw are used, never leave them lit without a container over 
them to disperse the main focus of heat. They could damage internal and external components of the 
hood, which would not be covered by the manufacturer’s guarantee.

• For high-powered cooking areas (more than 3.6Kw) it is recommended that the distance between the 
cooking area and the base of the hood be increased to 70 or 80cm (it moust be borne in mind that if the 
vertical gap is increased, the size, model and power of the motor need reviewing, being greater the more 
the height is increased).

• If a cooking area with high heating power is to be used, consult your distributor to choose the right hood 
model and for advice on use and installation.

Содержание UNE EN 60335-1

Страница 1: ...60335 The International Certification Network Quality Management System ISO 9001 2000 Certificado de Empresa de Gesti n de la Calidad UNE EN ISO 9001 2000 Certificaci n de Producto U L U S A Canad U...

Страница 2: ...manual is a guide to the correct installation use and maintenance to care for your new Extractor Hood The manufacturer is not liable for any inaccuracies due to printing or transcription errors which...

Страница 3: ...the power supply after installation This can be done by making the plug accessible or by fitting a circuit breaker in the electrical installation in accordance with the rules for the installation If t...

Страница 4: ...ntilation grille for this purpose Neither windows nor doors can serve this purpose The electrical mains power supply must be steady and meet the stated electrical requirements see the device features...

Страница 5: ...possible to discharge cooking fumes and steam outside the filter version of the hood may be used Fig 1 depending on the version consult distributor by fitting an active carbon filter kit The fumes and...

Страница 6: ...sure in the atmosphere and the hood motor will perform poorly OUTSIDE FLUE OUTLET The outlet of the flue must be covered with flaps which open under pressure diagram on page 5 Under no circumstances s...

Страница 7: ...curves or bends in the installation to a minimum If they do exist try to keep the angle as open as possible Drawing C WRONG RIGHT 3 Never fit reductions next to curves or bends in the installation The...

Страница 8: ...st have a stable voltage and meet the electrical requirements specified see device features panel The electrical system for the hood must be connected to a separate grid power supply as far as the fus...

Страница 9: ...e is damaged call the official after sales service to avoid any risks The appliance must be disconnected from the electrical grid during installation and maintenance work The mains power plug must be...

Страница 10: ...roach your Distributor or the Pando technical division responsible for hoods Each of these motors has its own full installation manual Part of the system for fitting them only is shown below To instal...

Страница 11: ...AILS AND MEASUREMENTS OF THE DIFFERENT TYPES OF EXTERNAL MOTOR AVAILABLE DEPENDING ON THE VERSION V 1200 Type 1 V 1400 Type 1 V 2100 Type 2 V 2500 Type 2 V 2500 Type 3 V 2100 Type 3 V 1400 Type 2 V 18...

Страница 12: ...LE HOSE MOTOR CONNECTION BOX 200 FLUE PIPE 4 MAINS CONNECTION MAINS CONNECTION CABLE ASPIRATION BOX DECORATIVE COOKER HOOD CABLE HOSE acts as extension between hood and motor 20mm blue brown yellow gr...

Страница 13: ...VERYIMPORTANT LocationofandaccesstotheMotormustbesafeforservicing sothatmaintenance can be performed easily Should the motor as installed present any risk to people Pando reserves the right not to se...

Страница 14: ...instalation maximum 4 linear m 4 linear m 4 linear m 4 linear m INTERNAL SEC System Motor Version V 750 V 850 V 950 V 1000 Flue diameter in mm INT 120 INT 150 INT 150 INT 150 Aspiration UNE EN 61591 m...

Страница 15: ...to motor 2m without elbows Up to 11 linear m Max distance from motor to Hood 4 m Available on Type 1 Up to 9 lineal meters max distance from hood to motor 4m without elbows EXTERNAL Motor Version V 2...

Страница 16: ...at the last speed set before it was switched off D Pressing this button increases the motor speed When the maximum speed is reached the LED on the button flashes on and off E Timer o Last time Pressi...

Страница 17: ...n while at speed 1 stops the motor C Pressing this button changes the motor to speed 2 medium suction D Pressing this button changes the motor to speed 3 maximum suction E Timer or Last time Pressing...

Страница 18: ...D E A B C D E A Pressing this button switches on and off the lights B Pressing this button starts the motor at speed 1 minimum suction Pressing it again while at speed 1 stops the motor C Pressing th...

Страница 19: ...D E For correct operation you are advised to keep the glass on the Touch Control panel clean and dry at all times A Pressing this symbol brings out the hood and and switches off the motor and lights...

Страница 20: ...ON OFF lights B OFF motor speed C Minimum motor speed D Medium motor speed E Maximum motor speed CONTROL PANEL A A B C D E F CONTROL PANEL B CONTROL PANEL C ON OFF lights ON OFF motor speed 3 speed s...

Страница 21: ...er hood and then restore power to the electronic control unit Within the next 15 seconds press the Light button this will ensure the control unit is synchronised with the new code Emergency button In...

Страница 22: ...ecessary to repeat the synchronisation process GENERATING A NEW TRANSMISSION CODE 1 Hood motor on and off 2 Reduce motor speed 3 Increase motor speed 4 Motor timer keeps the hood on for 10 minutes and...

Страница 23: ...STABLISHING FACTORY DEFAULT CONFIGURATION If you have changed the transmission code and want to recover the factory default code do the following Press simultaneously and keep pressed the three keys i...

Страница 24: ...be left after cleaning and give it a flawless regular finish Using ACID SODA AMMONIAC CHLORIDE or DERIVED products for cleaning is ESPECIALLY HARMFUL to stainless steel All of them can destroy the ch...

Страница 25: ...e or maintenance B Unauthorised changes to the goods or improper use C Use outside the limits of the specified conditions D Physical chemical direct or indirect such as acids in a gaseous state or mec...

Страница 26: ...or marked in different shades RECOMMENDATIONS Cleaning is recommended at least once every 10 days To maintain aluminium or steel filters under normal daily use of the hood it is advisable to replace t...

Страница 27: ...arbon filters are neither washable nor reusable 5 3 ACTIVE CARBON FILTER MAINTENANCE filter version only Fig 1 page 4 System A HOODS AND FILTER SYSTEMS UP TO 600 System C HOODS AND FILTER SYSTEMS UP T...

Страница 28: ...pressing where it says PUSH c Replace the bulb with a similar one TWO PIN max 20 W 12 Volt G4 fitting d Close the window If it does not close properly repeat the operation described under point B CAN...

Страница 29: ...nnected internally and pulling it too hard runs the risk of damaging the wiring 5 Undo the connector above the LED to be changed 6 Push the LED downwards according to the diagram at the same time pres...

Страница 30: ...suitable for compact hobs up to 90cm in width I 496 Only suitable for compact hobs 60 or 70cm in width I 497 90 Only suitable for compact hobs 60 or 70cm in width I 497 120 Only suitable for compact h...

Страница 31: ...be smaller than the hood i e the hood must project further than the cooking area by at least 10cm on each side COMPATIBILITY WITH THE HEATING POWER OF COOKING AREAS Our hoods are for domestic use and...

Страница 32: ...cted to the power supply look at the plug and the differential circuit breaker in the fuse box Check that there are no problems with the electrical power supply such as spikes and drops in voltage The...

Страница 33: ...at full power without pre heating improper use or maintenance of the hood and incorrect installation of the flue pipe The reason for this condensaiton effect is the following taking into account that...

Страница 34: ...ly installed and a motor system with the right power rating has been chosen A The hood should be switched on 5 minutes before starting to cook and the timer LAST TIME set after finishing cooking to cl...

Страница 35: ...s glass plastic and enamel which may have suffered impacts due to the above causes and also in the event that the flue pipe with which the purchaser s hood is to be installed is not suitable for the h...

Страница 36: ...THE FOLLOWING a Installation work and Electrical Wiring MUST be done by Qualified Person s in Accordance with all Applicable Codes and Standards including Fire Rated Construction b Sufficient air is...

Страница 37: ...especially suitable for polishing stainless steel surfaces Its complex formula based on paraffin derivatives leaves an invisible film which protects and polishes the surface USES Cleans polishes and...

Отзывы: