Pando E-250 Скачать руководство пользователя страница 10

 

 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

Corian version remote control. User Instructions.

1.  Hood motor on and off.
2.  Reduce motor speed.
3.  Increase motor speed.
4.  Motor timer, keeps the hood on for 10 minutes and then switches it off.
5.  Led indicator of control key pressed. Also indicates programming process.
6.  Light on and off. *.

* A short press switches the main light on or off, and in models with a courtesy light, this is controlled with a long push, 

keeping the key pressed for more than 2 seconds.

Synchronising the control with the hood:

When the hood is installed or if a change is made in the transmission code, it is necessary to synchronise the control with

 the hood control unit. The process is as follows: Disconnect and then reconnect the power supply to the hood (with the 

hood control unit switch or by unplugging the hood, or with the circuit breaker switch on the home electric panel), when 

the hood has ben reconnected to the mains supply, before 20 seconds have passed press the light key with the remote 

control pointing to the hood, the hood will light up, indicating that the process was correct.

If more than 20 seconds pass before you synchronise the control, the control unit will close the reception and no code will 
be recorded.

Attention!: Synchronisation of the remote control with the hood can be lost due to external reasons such as power cuts, 

electrical discharges, interference….In these cases it is necessary to repeat the synchronisation process.

Generating a new transmission code:

The manufacturer supplies the remote control ready for use, with the factory default codes.

If you want to generate new codes, do the following: Press simultaneously and keep pressed the three keys indicated in 
the illustration (1-2-3) until the LED (5) begins to flash, at that moment the control is going through the different frequencies 
available, when you release the keys, the led (5) will stop flashing and record the frequency being scanned at that 
moment.

If you want a different frequency, repeat the process (after re-establishing the factory default configuration), and the 
chosen frequency will depend on the time you keep the keys pressed.

ATTENTION! This operation will definitively delete the existing codes.

Re-establishing factory default configuration:

If you have changed the transmission code and want to recover the factory default code, do the following: Press 
simultaneously and keep pressed the three keys indicated in the illustration (1-2-3) until the LED (5) is permanently lit, at that 
moment, the control has re-established the factory default frequency.

ATTENTION! This operation will definitively delete the existing codes.

ATTENTION– WARNING – MAINTENANCE 

The battery must be replaced every year in order to guarantee optimum range of the transmitter.

To replace an exhausted battery, remove the back cover quite, remove the battery with care so as no to damage or deform 
the unit’s connection tabs, insert a new battery observing the indicated polarity.

Button type battery, Lithium model CR-2032 3V. Used batteries must be disposed of adequately.

Operating frequency 433.92 Mhz, 4096 combinations.

This product complies with R&TTE Directive 99/5/EC specifications. 

1        2      3

4 5 6

Содержание E-250

Страница 1: ...RANGE HOODS E 250 E 260 E 270 INSTALLATION GUIDE ...

Страница 2: ......

Страница 3: ...s included with the range hood allow you to adjust the height between 210 and 370 mm 2 CHOOSING THE EXTRACTION SIDE You have the option to chose the side of the extractor hood that the extracted air will flow through see fig 2 Once you have chosen the best position prepare the conduit the unit is supplied with a Ø150mm circular ring for the side outlet and another rectangular outlet 100x260 Leave ...

Страница 4: ...which screw into the frame The adjusting nuts can be used to set the required height for the extractor hood between 210mm and 370mm Drill the 4 holes into the ceiling following the measurements indicated on the drawing In sert the plugs supplied with the extractor hood into the holes and then screw in the rods OUTCUT 1300 1230 X 720 1600 1485 X 720 1900 1825 X 720 Page 3 INSTALLATION GUIDE E 250 E...

Страница 5: ...tor pipe connections the extractor hood has two Ø150 outlets and 2 100x260 Ø200 outlets one on the front and other on the side It also has Ø150 or Ø200 outlet on the top of the extractor hood for vertical pipe installations Power connection The model E 250 E 260 E 270 has one cable for the mains power con nection and another cable to connect the motor ...

Страница 6: ...must open the doors of the hood and remove the filters Insert the extractor hood into the niche fitting the threated rods into the corresponding holes the outer edge of the hood should line up perfectly with the false ceiling Place the small plates supplied with the extractor and the nuts on to the theaded rods and tighten them correctly Page 5 INSTALLATION GUIDE E 250 E 260 E 270 ...

Страница 7: ... The ON switch for the extractor hood is opposite the connection box If all the ceiling connections with the external or roof motor have been completed we may start up the hood IMPORTANT After starting up the hood please synchronize the remote control ins tructions on Page 7 Put the filters in their correct position and close the doors ...

Страница 8: ... re mote control to the hood and keep pressed the button Light until the lighst of the hood swith on 4 The operating frequence of the hood is recorded and the hood is synchronized Important When the hood is installed and the differencial case is switched on before 20 seconds pass please keep pressed the button light until the lights of the hood swith on This way the hood records the operating freq...

Страница 9: ...MPORTANT EXTERNAL MOTOR IN FALSE CEILING The dimensions of the external motor must be taken into account particulary if it is to be located at the same level as the false ceiling of the extractor hood See dimensions an appendix SUPPLIED ACCESSORIES these accessories are supplied with the hood 4 threaded rods of 8mm 8 washers Ø 24mm 4 washers Ø60mm 4 wingnuts of 8mm 4 wingnuts 8mm 4 metalic plugs o...

Страница 10: ...acturer supplies the remote control ready for use with the factory default codes If you want to generate new codes do the following Press simultaneously and keep pressed the three keys indicated in the illustration 1 2 3 until the LED 5 begins to flash at that moment the control is going through the different frequencies available when you release the keys the led 5 will stop flashing and record t...

Страница 11: ...INSTALLATION GUIDE E 250 E 260 E 270 APPENDIX EXTERNAL MOTORS DEMENSIONS ...

Страница 12: ...Página 10 ...

Отзывы: