PANAVISION PANALUX SONARA 4:4 Скачать руководство пользователя страница 12

Power Supply

1.  Ensure the power cable is disconnected before 

servicing. 

2.  SONARA only uses a mains connection. Do not 

connect to a variable supply such as a dimmer rack, 
variac, or inverter. 

3.  The power cable should be plugged into SONARA 

before switching the mains power supply ON. The 
mains power supply should be switched OFF before 
removing the power cable.

4.  SONARA is shipped with a 7A fuse in the casket. For 

use in 110V locations, this should be changed to a 15A 
version (15A fuse not included).

Safety Cables

1.  A minimum of one safety cable MUST be used when 

hanging SONARA from its yoke or eye bolts or using 
quick triggers. The length should be as short as 
possible to reduce travel distance if the primary hanging 
fails.

2.  The safety cable slot (as shown on page 11) MUST be 

used to attach a safety cable.

3.  Ensure safety cables are capable of supporting the 

combined load of the SONARA and accessories.

Note

SONARA has been built to conform to international 
regulatory standards relating to professional lighting 
equipment. Any modification made to SONARA will void the 
manufacturers’ warranty.

Approvals

EU

EN 55015:2013
EN 61547:2009
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 61000-4-2:2009
EN61000-4-3:2006+A1:2008+A2:2010
EN 61000-4-4:2012
EN 61000-4-5:2006
EN 61000-4-6:2009
EN 61000-4-8:2010
EN 61000-4-11:2004

FCC

47 CFR of part 15

CSA 
and UL

CSA C22.2 No. 250.4-14
CAN/CSA C22.2 No. 250.13-14
UL Standard No. 153
UL Standard No. 8750

Certifications

ROHS

EPA3050B:1996
EN1122B:2011
EPA3052:1996
EPA7196A:1992
APE3540C:1996
EPA8270D:2007

Europe

EN / IEC 62471

LATEST VERSION AS OF JULY 2021

PANALUX SONARA 4:4 USER MANUAL

12

Содержание PANALUX SONARA 4:4

Страница 1: ...The next generation enhanced variable white LED soft light S O N A R A 4 4 LATEST VERSION AS OF JULY 2021 User manual of SONARA 2021 Panalux Ltd All Rights Reserved...

Страница 2: ...The next generation enhanced variable white LED soft light S O N A R A 4 4 LATEST VERSION AS OF JULY 2021 User manual of SONARA 2021 Panalux Ltd All Rights Reserved...

Страница 3: ...Spare Parts Accessories 08 Appendix Gel Library Source Emulation List Overall Dimensions Rigging Centres 01 Important Information Warnings Safety Information Changes Measuring Correlated Colour Tempe...

Страница 4: ...IMPORTANT INFORMATION WARNINGS 01...

Страница 5: ...o measure the light output red green and blue As such a narrow band or discontinuous spectrum light source may not read correctly Colour meters such as the Sekonic C800 Spectromaster or UPR Tech MK 35...

Страница 6: ...gsten lights 0 10 With multi colour LED fixtures in particular older Stage and Architectural LED fixtures where compatibility with film and digital cameras wasn t a consideration in their design indiv...

Страница 7: ...INTRODUCTION 02...

Страница 8: ...etween nodes lighting fixtures and a lighting desk typically on a private local network such as Ethernet Art Net can address over 30 000 universes Art Net designed by and copyright Artistic Licence Ho...

Страница 9: ...USER INSTRUCTIONS 03...

Страница 10: ...g quick triggers 4 in each corner and 2 on the outer edge of the back roughly aligned with the centre line and yoke mounting position 5 SONARA weighs 44kg excluding accessories and 38kg excluding yoke...

Страница 11: ...hes a maximum surface temperature of 85 C Please ensure contact on the surface by persons or materials is avoided when the fixture is operating 6 Do not operate SONARA if there are any signs of physic...

Страница 12: ...nging fails 2 The safety cable slot as shown on page 11 MUST be used to attach a safety cable 3 Ensure safety cables are capable of supporting the combined load of the SONARA and accessories Note SONA...

Страница 13: ...FIXTURE OVERVIEW 04...

Страница 14: ...hrough 5 pin DMX connector or via wireless DMX The SONARA user interface and wired remote have been designed to provide a clear and simple display of essential information The controller features 1 ro...

Страница 15: ...of the controller and the other Lemo connector is inside the controller holding trough The controller features magnets and a lanyard to hang on a stand lock off There is a safety for the controller on...

Страница 16: ...ARA Mounting Components Spigot Locking Handle Corner M12 Mounting Points Mounting Point Fitted With M12 Eyebolt Centre M12 Mounting Points LATEST VERSION AS OF JULY 2021 PANALUX SONARA 4 4 USER MANUAL...

Страница 17: ...MX signals The DMX wiring is as follows Pin 1 Ground Pin 2 Data Pin 3 Data Pin 4 Spare Pin 5 Spare Please note SONARA is self terminating and does not require external DMX termination when used in a c...

Страница 18: ...OPERATION 05...

Страница 19: ...Art Net LOCKED when local control is locked DEMO when fixture is cycling through a demo In white mode shown above the display will always show Dim Position percentage CCT Green Magenta Bias Factory R...

Страница 20: ...r it scrolls through the CCT range or gel list for example When controlling the dimming for instance this allows ultra fine control down to 0 1 steps Selector Buttons 3 selector buttons allow the user...

Страница 21: ...t button touch will display the saved settings and the bar will turn red without changing the light output A second touch will change the output The scene memory can be overwritten Restoring to factor...

Страница 22: ...me and number Full gel list in the Appendix pp 39 41 In this screen the live highlighted bottom button NAME in the top left example image allows toggling of LIVE ON and LIVE OFF In LIVE OFF mode you c...

Страница 23: ...chart If the chosen colour point is out of gamut SONARA won t produce any output until the coordinates are adjusted to bring it within the achievable gamut The light will switch off during adjustment...

Страница 24: ...CONTROL FEATURES OPTIONS 06...

Страница 25: ...uilt in dimming curves CONTROL FEATURES OPTIONS Curve Characteristics Linear Default In linear mode 50 equates to half the output or 1 stop down 25 is quarter output or 2 stops down Square Law A squar...

Страница 26: ...etric output changes at different CCTs In a studio environment where multiple changes are made to CCT it is often advantageous that the photometric output remains constant This is achieved in FLAT mod...

Страница 27: ...inates which would be shown in a red font on the display In CCT HSI ALB or GEL mode if the colour is unachievable due to the chosen gamut the colour produced will be desaturated into the selected whit...

Страница 28: ...tions from any This allows a DOP or gaffer to ride the dimmer when the talent is moving to a cue or during setup to make changes whilst talking to the board operator who may be backstage External Igno...

Страница 29: ...L GEL P7 Gel Hue 24 bit BCD DIM CCT Gn GEL 000 GEL 00 GEL 0 HUE SAT P8 Gel Hue 16 bit DIM DIM CCT CCT Gn GEL GEL HUE HUE SAT SAT P9 ALB 8 bit DIM AMBER LIME BLUE P10 ALB 16 bit DIM DIM AMBER AMBER LIM...

Страница 30: ...toring 2 RDM Protocol Version Monitoring 3 Device Model Description Fixed 4 Manufacturer Label Fixed 5 Software Version Fixed 6 Serial Number Fixed 7 DMX Footprint Monitoring 8 DMX Personality Descrip...

Страница 31: ...perature in degrees Celsius 8 Temperature Array temperature in degrees Celsius 9 Temperature Array temperature in degrees Celsius 10 Temperature Array temperature in degrees Celsius 11 Temperature Arr...

Страница 32: ...PRIMARY CLONE MODE STANDARD PIXILATION SFX ATTRACT CONTROL CURVES LINEAR SQUARE LAW S CURVE TUNGSTEN EMULATE OUTPUT BOOST FLAT GAMUT PX VARI WHITE REC 2020 REC 709 DCI P3 ESTA 1 54 CAMERA LUTS CONTRO...

Страница 33: ...GENERAL 07...

Страница 34: ...at the keyway aligns Two or more fixtures on the same address are behaving differently on dimming or CCT Ensure that all fixtures are set in the same option for personality dimming curve and FLAT BOOS...

Страница 35: ...d below were taken with a SONARA at 3200K as above Sonara Luminous Intensity Height m Lux lx at Spread m Centre 1 2 2 4 3 7 4 9 6 1 7 3 8 5 9 8 11 0 12 2 3 2197 1859 1639 1420 1082 845 625 473 355 287...

Страница 36: ...the light to human eyes Disconnect Device When the appliance inlets of any individual SONARAs are not accessible the socket outlets supplying the rack shall be installed near the equipment and be easi...

Страница 37: ...ller extension cable pouch 124 8684 Aerial VIKLIA7 Power cord YJNBQAJ Soft box YIN9PAR Soft box bag JIN9RAR Full Grid Cloth JIN9SAR Half Grid Cloth JIN9TAR Quarter Grid Cloth JIN9QAR Magic Cloth GJNBP...

Страница 38: ...APPENDIX 08...

Страница 39: ...reen 89 Moss Green 90 Dark Yellow Green 101 Yellow 102 Light Amber 103 Straw 104 Deep Amber 105 Orange 106 Primary Red 107 Light Rose 108 English Rose 109 Light Salmon 110 Middle Rose 111 Dark Pink 11...

Страница 40: ...d 165 Daylight Blue 169 Lilac Tint 170 Deep Lavender 172 Lagoon Blue 174 Dark Steel Blue 176 Loving Amber 179 Chrome Orange 180 Dark Lavender 181 Congo Blue 182 Light Red 183 Moonlight Blue 184 Cosmet...

Страница 41: ...727 QFD Blue 728 Steel Green 729 Scuba Blue 730 Liberty Green 731 Dirty Ice 733 Damp Squib 735 Velvet Green 736 Twickenham Green 738 JAS Green 740 Aurora Borealis Green 741 Mustard Yellow 742 Bram Br...

Страница 42: ...vapour 908 Xenon 909 Arena lighting 910 Frosty night 911 912 913 914 915 916 917 918 919 920 Fluorescent Warm White 921 Fluorescent Neutral White 922 Fluorescent Cold White 923 Fluorescent Old and gre...

Страница 43: ...Overall Dimensions Rigging Centres LATEST VERSION AS OF JULY 2021 PANALUX SONARA 4 4 USER MANUAL 43...

Отзывы: