1
3 RATED SPECIFICATIONS
3.1 SPECIFICATIONS TABLE
Type
YC-500WX
Rated input Voltage
V
400V±10%
Phase
——
Three phase
Rated input
kVA/kW
DC TIG
21.5/19
AC TIG
29.5/22.5
the power source efficiency
%
72.8%
the idle state power consumption
Watts(W)
152
Rated input
Hz
50/60
Rated duty cycle
%
60
No load voltage
V
Voltage reducing "NO":14
V
Voltage reducing "OFF":76.5
DC Output current
TIG
A
5~500
Stick
A
50~400
AC Output current
MIX TIG
A
20~500
A.C.STD.TIG
A
20~500
A.C.HARD.TIG
A
40~500
A.C.SOFT.TIG
A
20~330
Rated D.C output
voltage
TIG
V
10.2~30
Stick
V
22~36
Rated A.C output
voltage
MIX TIG
V
10.8~30
A.C.STD.TIG
V
10.8~30
A.C.HARD.TIG
V
11.6~30
A.C.SOFT.TIG
V
10.8~23.2
Initial/Crater
current
AC
MIX TIG
A
20~500
A.C.STD.TIG
A
20~500
A.C.HARD.TIG
A
40~500
A.C.SOFT.TIG
A
20~330
DC
TIG
A
5~500
Upslope time
S
0 or 0.1~5
Downslope time
S
0 or 0.2~10
Gas preflow time
S
0.3
Gas postflow time
S
2~20
Cleaning width
MIX TIG·AC(STD·HARD·SOFT)TIG
Pulse frequency
Low pulse
Hz
0.5~25
Middle pulse
10~500
Pulse width
%
15~85
MIX TIG frequency
Hz
0.5~10
Crater control process
——
"ON" "OFF" "REPEAT"
Outside dimension
mm
440
(
W
)
×635
(
D
)
×1046
(
H
)
Insulation class
——
H(200
℃
)
EMC classification
——
Class A
Mass
k
g
121
NOTE:
1.This equipment does not comply with IEC 61000-3-12. If it is connected to a public low voltage system,
It is the responsibility of the installer or user of the equipment to ensure, by consultation with the
distribution Network operator, that the equipment may be connected.
2.System maximum impedence requirements at the interface point of the users supply: Maximum
permissiblen System impedence 0.446
Ω.
Содержание YC-500WX
Страница 2: ......
Страница 20: ...13 ...
Страница 21: ...14 ...
Страница 30: ...23 12 CIRCUITDIAGRAM ...
Страница 31: ...24 13 PARTS LAYOUT DRAWING ...
Страница 34: ...27 15 OUTLING DRAWING ...