29
Adjustment
z
Adjust the camera angle. When determining the camera angle, repeat fine adjustments by
gradually moving the panning table, tilting table, and azimuth adjustment ring.
Horizontal position (Panning)
Loosen the panning lock screw, rotate the panning table to adjust the pan direction. (Adjustable
range: 350 °)
Panning is possible within the range of 180 ° (when panning clockwise) and 170 ° (when panning
counterclockwise). After adjustment, tighten the panning lock screw to fix the panning table.
(Recommended tightening torque: 0.39 N.m {0.29 lbf·ft})
FRONT
TOP
MONITOR
OUT
LOCK
12V=IN
BASE-T/
BASE TX
EXT
TOP
Home position markers
K
Panning table
Panning lock screw
[LOCK]
Home position
* The position where the home
position markers are aligned
Counterclockwise panning
end maker: (Rotation within
the range of 170 °)
Clockwise panning end
marker: (Rotation within the
range of 180 °)
Vertical position (Tilting)
Loosen the tilting lock screws (x2), and rotate
the tilting table to adjust the tilting direction.
(Adjustable range: ±75 °) Since a variable focal
lens is used, it is possible to change the angu-
lar field of view. This lens can also be rotated in
the reverse direction, but the image azimuth is
reversed. In this case, the image azimuth can
be modified when the panning table is rotated
to the direction of clockwise panning (180°).
<Lens angular field of view (
q
Angle)>
Horizontal: 27.7 ° (TELE) to 100.3 ° (WIDE)
Vertical: 20.8 ° (TELE) to 73.5 ° (WIDE)
After adjustment, tighten the tilting lock screws (x2) to fix the tilting table.
(Recommended tightening torque: 0.59 N·m {0.44 lbf·ft})
+75 °
–75 °
Adjustable range