10. Video Output Connector (VIDEO OUT)

This BNC type connector is used to provide the video
output signal of the source to an additional monitor or
video cassette recorder.

11. Video Input Connector (VIDEO IN)

This BNC type connector is used for receiving the
video signal from a source to be monitored, such as a
VCR.

12. Video Termination Switch (75 

/HiZ)

Set this switch to the 75 

position for a single monitor

connection.
For a multiple monitor connection, set this switch to
the 75 

position on the last monitor in the series, and

to the HiZ position for the other monitors.

13. Power Cord

CONNECTIONS

Power Cord

1. Keep the Power ON/OFF switch of the camera in the

OFF position during installation.

2. Connect the Power Cord to a grounded electrical out-

let.

Video Cable

Use a 75 

coaxial cable (RG-59, RG-59A/U, RG-59B/U,

RG-59/U, RG-6/U, or RG-11/U).

1. Up to 10 monitors can be hooked up in this configura-

tion before signal loss occurs. Total cable length
should not be longer than 150 meters (500 feet).

2. Wiring Precautions :

Do not bend the coaxial cable into a curve whose
radius is smaller than 10 times its diameter.
Never staple coaxial cables, not even with circular sta-
ples.
Never crush or pinch the cable.
All of the above will change the impedance of the
cable and cause poor picture quality.

OUT

VIDEO

IN

OUT

VIDEO

IN

Camera

Monitor

Monitor

Coax.
Cable

Coax.
Cable

Содержание WVBM1410 - B/W MONITOR

Страница 1: ...Video Monitor WV BM1410 Before attempting to connect or operate this product please read these instructions completely ...

Страница 2: ... lightning flash with arrowhead sym bol within an equilateral triangle is intended to alert the user to the pres ence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilat eral triangle is intended to alert the user to the presence of important operating and maint...

Страница 3: ...ure Do not operate the monitor if it becomes wet Turn the power off immediately and ask a qualified service person for servicing Moisture can damage the monitor and also create the danger of electric shock Do not drop metallic parts through the ventilation slots This action could permanently damage the monitor If metallic parts should fall through the ventilation slots turn the power off immediate...

Страница 4: ...tal position of the picture 5 Vertical Hold Control V HOLD This control is used to lock the vertical position of the picture 6 Height Control HEIGHT This control is used to adjust the height of the picture 7 Bright Control BRIGHT Turn this control clockwise to increase the picture brightness Turn this control counterclockwise to decrease the picture brightness 8 Vertical Linearity Control V LIN Th...

Страница 5: ...ower Cord CONNECTIONS Power Cord 1 Keep the Power ON OFF switch of the camera in the OFF position during installation 2 Connect the Power Cord to a grounded electrical out let Video Cable Use a 75 Ω coaxial cable RG 59 RG 59A U RG 59B U RG 59 U RG 6 U or RG 11 U 1 Up to 10 monitors can be hooked up in this configura tion before signal loss occurs Total cable length should not be longer than 150 me...

Страница 6: ...ut Connector of the video source with a coaxial cable Connect the Video Output Connector VIDEO OUT on this monitor to the Video Input Connector VIDEO IN on the second monitor with a coaxial cable Complete the connections of all monitors in the system according to the above procedure Set the Video Termination Switch to the 75 Ω position on the last monitor and to the HiZ position on the other monit...

Страница 7: ... HOLD until the picture is stabilized 3 If the picture rolls up or down adjust the Vertical Hold Control V HOLD until the picture is stabilized 4 The sub controls HEIGHT and V LINEARITY should be adjusted at the same time to give proper vertical height consistent with good vertical linearity Extending the picture height approximately 6 mm 1 4 beyond the top and bottom edges of the CRT mask is reco...

Страница 8: ...to the four holes on the monitor and attach with screws provided with the Adapter 4 Mount into EIA Standard 19 Rack 5 Attach the monitor to the rack with rack mount screws not provided Caution If a fan is used to keep the temperature in the rack below 50 C 122 F it should be installed away from the monitor to avoid picture disturbance Left Rack Mount Screws Cover Fixing Screws Rubber Feet Fixing S...

Страница 9: ...canning Size Normal or underscan switchable Tube Size 322 mm 12 11 16 diagonal actual visual size 347 mm 13 11 16 diagonal tube screen size Ambient Operating Temperature 10 C 50 C 14 F 122 F Ambient Operating Humidity Less than 90 Dimensions 320 W X 325 5 H X 328 D mm 12 5 8 W X 12 13 16 H X 12 15 16 D Weight 10 kg 22 lbs Weight and dimensions shown are approximate Specifications are subject to ch...

Страница 10: ... 348 7303 Southeast 1225 Northbrook Parkway Suite 1 160 Suwanee GA 30174 770 338 6835 Midwest 1707 North Randall Road Elgin IL 60123 847 468 5200 Southwest 8105 Beltsline Road Suite 100 Irving TX 75063 214 915 1333 Western 6550 Katella Ave Cypress CA 90630 714 373 7265 PANASONIC CANADA INC 5770 Ambler Drive Mississauga Ontario L4W 2T3 Canada 905 624 5010 PANASONIC SALES COMPANY DIVISION OF MATSUSH...

Отзывы: