<Lens angular field of view (
q
Angle)>
Horizontal: 24.20° (TELE) to 86.60° (WIDE)
After adjustment, tighten the tilting lock screws (x2) to fix the tilting table.
(Recommended tightening torque: 0.59 N·m {0.44 lbf·ft})
Note:
• When the tilting table is turned to the edge of the adjustable range (±75°), it must be noted that
the shadow of the enclosure may be projected.
• When the camera is installed to a wall, the image is reversed in the default settings. To correct
the way the image is displayed, rotate the panning table 180° clockwise, or select "On" for
"Upside-down" from the setup menu. For information about performing the "Upside-down" set-
ting from the setup menu, refer to the Operating Instructions (included in the CD-ROM).
Image tilt adjustment
Rotate the azimuth adjustment ring to adjust the azimuth angle of the image. (Adjustable range:
±100 °)
Adjustable range
–100 °
+100 °