background image

(3)

 Fix the 

B

 base bracket (accessory) on a ceiling or a wall by following the instructions on “[1] 

Mount the camera to a ceiling or a wall using base bracket” of “Step 1 Fixing the brackets [1]” 
on the “Installation Guide” of WV-SFV781L and fix the 

A

 attachment plate (accessory) on the 

base bracket.

 

When directly attaching the attachment plate to a two-gang junction box or a ceiling/wall, read 
“A Fixing the brackets [2] [3]”.

(4)

  Connect the camera with the cables and 

mount on the attachment plate by following 

q

 - 

e

 of “Step 2 Mount the camera to the 

attachment plate".

(5)

  Hitch the hook at the tip of the safety wire to 

the wire lug plate fixed on a ceiling or a wall.

IMPORTANT:

•  Once the safety wire is attached, do not 

detach it.

Note:

• When the safety wire is short, connect 

the 

M

 extended safety wire (accessory) 

to the snap hook of the safety wire.

•  

Adjust the fixing position so that the 
extended safety wire does not sag.

(6)

 Return to 

r

 of “Step 2 Mount the camera to the attachment plate” on the “Installation Guide” 

of WV-SFV781L and continue the installation work by following instructions.

Safety wire

B

  Base bracket 

(accessory)

A

  Attachment plate 

(accessory)

Safety wire

Snap hook

Wire lug plate

Securing a safety wire

Before starting installation of WV-SFV781L, install the wire lug plate on a ceiling or a wall.
Perform the installation work of “Step 1 Fixing the brackets [1]” and “A Fixing the brackets [2] [3]” 
on the “Installation Guide” of WV-SFV781L by following the procedures below.

(1)

   Detach the wire lug plate from the snap hook 

for the safety wire for camera drop prevention.

(2) 

Make a hole near an installation place of the camera and fix the wire lug plate with the fixing 
screw (locally procured)*

1

.

*1  When installing this product on a ceiling or a wall, attachment of the safety wire (already 

equipped with the camera) is necessary. Separately prepare an M6 bolt-nut or an anchor 
(Minimum pull-out strength: 724 N {74 k

g

f}) to fix the safety wire.

<Hole position when installing on a ceiling>

<Hole position when installing on a wall>

FRONT

150 {5-29/32}

130 {5-1/8}

20 {25/32}

50 {1-31/32}

R 125

TOP

50 {1-31/32}

130 {5-1/8}

20 {25/32}

150 {5-29/32}

R 125

*  The above figure indicates the available area to fix the wire lug plate when installing the camera. 

Determine the position to fix the wire lug plate in this area.

<How to fix the wire lug>

IMPORTANT:

•  Install the wire lug plate in the foundation part of the building or where sufficient strength 

is assured.

•  Installation height (the lowest part of the camera after the installation) of the camera shall 

be 2 m 80 cm high from the floor or higher.

Wire lug plate

M6 bolt-nut or anchor 
(locally procured)

Wire lug plate

Ceiling

Wall

Snap hook

Safety wire

Wire lug plate

<Example of mounting on the wall>

Unit: mm {inch}

Unit: mm {inch}

Отзывы: