16
SF N
480
• Locations where it may get wet from rain
or water splash (including under the eaves,
etc.)
• Locations subject to moisture or dust
• Locations subject to condensation as the
result of severe changes in temperature (In
case of installing the camera in such loca-
tions, the lens may become foggy or con-
densation may be caused on the cover.)
• Locations subject to vibrations, such as on
vehicles, marine vessels, or above product
lines (This product is not designed for on-
vehicle use.)
Check before installation
Compatibility of devices is restricted. Before
installation, check the ratings and dimensions
of the devices to be used.
Contact your dealer for details.
Before installation
• Use the attachment plate (accessory),
base bracket (accessory)
SF V
481
, or an
optional mount bracket to install the cam-
era on the ceiling or wall.
• Anchor bolts and screws used to mount
the camera on the ceiling or wall are not
supplied. Prepare bolts and screws that
match the structure and materials of the
installation location and satisfy the perfor-
mance and reliability specifications shown
below.
Required screws: M4 (4 pcs.)
Minimum pull-out strength: 196 N {44 lbf}
(per 1 pc.) (when the camera is installed on
the ceiling or a wall using the attachment
plate (accessory) or the base bracket
(accessory)
SF V
481
)
Screw tightening
• The screws and bolts must be tightened
with an appropriate tightening torque
according to the material and strength of
the installation area.
• Do not use an impact driver. Use of an
impact driver may damage the screws or
cause tightening excessively.
• When a screw is tightened, make the
screw at a right angle to the surface. After
tightening the screws or bolts, perform
checks to ensure that the tightening is
sufficient enough so that there is no
movement or looseness.
Do not remove or loosen the screws on
the bottom of this product.
If the screws (7 pcs.
SF V
481
, 6 pcs.
SF N
480
) are loosened, water exposure may
cause damage
SF V
481
or malfunction of
the product, or dropping may result in injury.
<Bottom side of WV-SFV481> <Bottom side of WV-SFN480>
Installing in low temperature environments
SF V
481
The camera can be used even outdoors in low-
temperature environments as low as -40 °C
{-40 °F}, but in an extremely low-temperature
environment below -10 °C {14 °F}, snow and
frost may not be defrosted from the dome
cover. When this product is installed and oper-
ated in low temperatures below -20 °C {-4 °F},
normal images may not be obtained immedi-
ately after startup. In such a case, wait for
about 2 hours with the power connected, and
then disconnect and reconnect the power
again.