Step4
Attach the enclosure to the camera
1
Use the last fixing screw (1 pc., with washer) to secure
the auxiliary wire from the camera body to the enclo-
sure. (Recommended tightening torque: 0.78 N·m
{0.58 lbf·ft})
Position and secure the flat side of the end of the auxil-
iary wire to the dome cover anchor bracket with the
screw. (Make sure not to position the end of the auxil-
iary wire above the protrusion.)
2
Secure the camera to the enclosure with the 2 enclo-
sure fixing screws.
(The recommended tightening torque of the enclosure
fixing screws is 0.59 N·m {0.44 lbf·ft})
⇒
Refer to the Installation Guide for more information
about installing the camera.
IMPORTANT:
●
When the enclosure is attached, the camera's focus
may go out of focus. Use the "Auto focus" function in
the setup menu to adjust the focus.
●
Remove the cover film after installation is complete.
●
If there are fingerprints or dirt on the dome cover, wipe it clean with a soft cloth.
End of the
auxiliary wire
Protrusion
Fixing screw
(1 pc., with washer)
Specifications
Standard Accessories
Ambient operating temperature: –10 °C to +50 °C {14 °F to 122 °F}
Mass:
Approx. 61.0
g
{0.13 lbs}
Dimensions:
Diameter: 108 mm {4-1/4 inches}
Height : 59.5 mm {2-11/32 inches}
Diameter of the dome: 41.5 mm {1-5/8 inches}
Operating Instructions .................................... 1 set