5-11
Troubleshooting
5.2 Self-diagnostics/Machine Malfunctions
1.
User error: U code
Error
code
Description
Check Item
U1
Right cover (opened)
1) Is the right cover closed?
2) Contact failure of the right cover open/close
sensor connector
3) Right cover open/close sensor malfunction
4) Contact failure of the low voltage power supply PCB
connector
5) Low voltage power supply PCB malfunction
6) Contact failure of the main CPU PCB connector
7) Main CPU PCB malfunction
Error
code
Description
Remarks