Panel Details

q

Operation Indicator (OPERATE)

The operation indicator is on when the power of the
WJ-MPU955A is turned on and the OPERATE switch is
pressed. The operation switch of the CPU is located
behind the front panel.

w

Screws

These screw are removed to detach the front panel.

e

Fan Alarm Indicator (FAN ALARM)

FAN ALARM indicator shows the cooling fan status.
This indicator lights when the cooling fan has a trouble,
and keeps lighting until the power is turned off. In such
case, turn the power off and refer servicing to qualified
service personnel as soon as possible.

Note:

This indicator lights for around five seconds after

the power is turned on. That is the normal status.

r

Hard Disk Drive Indicator (HDD)

This HDD indicator shows the hard disk drive status.

t

Active Indicator (ACTIVE)

This ACTIVE indicator shows the system status of the
WJ-MPU955A.

y

Operation Switch (OPERATE)

When this switch is pressed, the unit will operate while
the POWER switch is ON. To stop the operation, hold
down this switch for around five seconds.

Note:

The AC power is still on even when the OPER-

ATE switch is off.

u

Redundant Selector (REDUNDANT YES/NO)

This selector is reserved for future use.

i

Mode Selector (REDUNDANT AUTO/MANUAL)

This selector is reserved for future use.

o

Reset Button (RESET)

This button is pressed to reset the CPU.

Note:

In normal operation, you need not press the but-

ton.

!0

Test ports (TEST)

These ports are used only for factory tests. Do not con-
nect anything.

!1

Ethernet Ports (10BASE-T/100BASE-TX)

These Ethernet Ports exchange control data via
Ethernet. The CPU can contain up to three Ethernet
ports. In a standard setup, we suggest you use the
[SYSTEM CONTROLLER] port for system controllers
while the [SYSTEM DEVICE] port for video encoders
and decoders. The [OTHER] port is reserved for future
use.

Note:

MPEG2 Encoder (WJ-GXE900) and MPEG2

Decoder (WJ-GXD900) support the NTSC model
only.

!2

Peripheral Interface Ports (SERIAL)

These ports are reserved for future use or factory tests.

!3

Cooling Fan Unit

This cooling fan unit prevents the temperature of the
CPU from rising. Do not block the ventilation opening
on the cover.

!4

Power Switch (POWER ON/OFF)

I:

ON

O:

OFF

!5

AC Inlet Socket (AC IN)

Plug the power cord (supplied as a standard accesso-
ry) into this socket and connect it to an AC outlet.

Содержание WJMPU955A - CENTRAL PROCESSING UNIT

Страница 1: ...t or operate this product please read these instructions carefully and save this manual for future use Central Processing Unit WJ MPU955A FAN ALARM HDD ACTIVE OPERATE Central Processing Unit Installation Guide Model No WJ MPU955A ...

Страница 2: ... diese Erklärung bezieht mit der folgenden Normen oder normativen Dokumenten übereinstimmt Gemäß den Bestimmungen der Richtlinie 73 23 EEC und 89 336 EEC Nous déclarons sous note seule responsabilité que le produit auquel se réfère la présente déclaration est conforme aux normes ou autres documents normatifs conformément aux dispositions des directives CEE 73 23 et CEE 89 336 FOR YOUR SAFETY PLEAS...

Страница 3: ...uction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense FCC Caution To assure continued compliance example use only shielded interface cables when connecting to com puter or peripheral devices Any changes or mo...

Страница 4: ... your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the app...

Страница 5: ...O LTD BE LIABLE TO ANY PARTY OR ANY PERSON EXCEPT FOR CERTAIN WARRANTY PROGRAM OFFERED BY THE LOCAL DEALER OF PANASONIC FOR THE CASES INCLUDING BUT NOT LIMITED TO BELOW 1 ANY DAMAGE AND LOSS INCLUDING WITHOUT LIMITATION DIRECT OR INDIRECT SPECIAL CONSEQUENTIAL OR EXEMPLARY ARISING OUT OF OR RELATING TO THE PRODUCT 2 PERSONAL INJURY OR ANY DAMAGE CAUSED BY INAPPROPRIATE USE OR NEGLIGENT OPERATION O...

Страница 6: ...ork Security System is a truly network based system and all the devices in the system are connected through IP based networks Layout The following diagrams are the front panel and the rear panel of the WJ MPU955A Front View Front panel attached Front panel detached Rear View 10BASE T 100BASE TX SERIAL 2 1 OTHER SYSTEM DEVICE SYSTEM CONTROLLER POWER ON AC IN OFF SIGNAL GND 2 1 3 4 5 Central Process...

Страница 7: ... AC power is still on even when the OPER ATE switch is off u Redundant Selector REDUNDANT YES NO This selector is reserved for future use i Mode Selector REDUNDANT AUTO MANUAL This selector is reserved for future use o Reset Button RESET This button is pressed to reset the CPU Note In normal operation you need not press the but ton 0 Test ports TEST These ports are used only for factory tests Do n...

Страница 8: ...rocured 4 pcs Refer to the following illustra tion Important The cooling fan inside the unit is perishable and must be replaced periodically If the rack is subject to vibration secure the rear of the unit to the rack by using additional mounting brackets locally pro cured To avoid loosening secure the mounting screws surely Mount the unit into the rack with a space equivalent to approx 1 unit 44 m...

Страница 9: ...ure 5 C to 45 C 41 F 113 F Ambient Operating Humidity Less than 90 Dimensions 420 mm W x 88 mm H x 350 D mm excluding rubber feet and projections 16 9 16 W x 3 7 16 H x 13 3 4 D Weight 9 kg 19 8 lbs Weight and dimensions indicated are approximate Specifications are subject to change without notice Standard accessories Installation Guide This Document 1 pc CD ROM 1 pc Note The files specified below...

Страница 10: ...rademarks of Adobe Systems Incorporated in the United States and other countries WHAT IS INCLUDED ON CD ROM Administration Console Software Time Management Utility TMU Software Administration Console sample database Admin Console User s Guide Time Management Utility User s Guide Operating Instructions SYSTEM REQUIREMENTS Minimum Hardware Requirements PC with an Intel Pentium III processor 64 MB me...

Страница 11: ...on For business users in the European Union If you wish to discard electrical and electronic equipment please contact your dealer or supplier for further information Information on Disposal in other Countries outside the European Union This symbol is only valid in the European Union If you wish to discard this product please contact your local authorities or dealer and ask for the correct method o...

Страница 12: ...gin IL 60123 Southern 1225 Northbrook Parkway Suwanee GA 30024 Western 6550 Katella Ave Cypress CA 90630 Panasonic Canada Inc 5770 Ambler Drive Mississauga Ontario L4W 2T3 Canada 905 624 5010 http www panasonic ca Panasonic Sales Company Division of Panasonic Puerto Rico Inc San Gabriel Industrial Park 65th Infantry Ave KM 9 5 Carolina P R 00985 809 750 4300 2006 Matsushita Electric Industrial Co ...

Отзывы: