CONTROLLING THE CONTACT OUTPUT
It is possible to designate the output port, output type (open/close), and output time of the control pulse which is
supplied from the contact output port of the encoder.
■
Format
■
Response
■
Important Notice
• The output time will be invalid when "momentary" is selected for the output mode.
■
Item List
Item
Parameter name
Parameter value
Description
Output port
PIO
1 - 4
Designate the output port
Output mode
OUT
latch
Supply the pulse from the output port dur-
ing designated output time
momentary
Trigger output will be supplied for around
300 seconds
Output type
TYPE
open, close
Designate the output type
Output time
TIME
1 - 1 800
Designate the output time (unit x 100 ms)
Valid only when "latch" is selected for the
output mode.
0