Panasonic WJ-NX100/2E Скачать руководство пользователя страница 28

28

Step 8

When you wish to change the registered camera numbers, 
it is possible to change the order of the camera numbers.

Images from the cameras will be displayed on the monitor 
from the upper left corner to the right in order of the camera 
number (1, 2 ... 4).
To interchange camera numbers, drag the camera image to 
be moved with the mouse and drop on the desired position.
If the camera titles are to be interchanged as well, mark the 
"Also change camera titles" checkbox.

[Camera status]

The model numbers and statuses of each camera will be 
displayed in a list.

Displaying image: Displays the images from the camera 

using the IP address that is newly registered or that 
has already been registered.

Changing IP address: Images are being obtained from 

the camera whose IP address has been changed.

Undetectable: Cannot obtain images from the camera.
Authentication error: Failed in the authentication to 

display images from the camera.

Important:

•  If "Undetectable" is displayed, check the camera 

connections, and retry the camera registration.

•  If "Authentication error" is displayed, initialized the 

camera and retry the camera registration by referring to 
the operating instruction of the camera.

•  If the registered camera is not correctly detected or if 

you wish to change the camera settings, change the 
registered information on the "Basic setup" menu - the 
"Camera" page - the "Camera registration" tab.  
(

 Operating Instructions (PDF))

[Refresh] button

Obtain the latest camera image after interchanging cameras.

[Exit] button

Exits the setup menu and returns to the top screen of the 
setup menu.

[Next] button

Proceeds to the settings for recording.

Step 9

Perform the settings for recording. If the settings are 
performed on "Easy Start", the settings will be applied 
to all the cameras.

[Frame rate]

Select the recording frame rate.
 

1 ips/ 3 ips/ 5 ips/ 10 ips/ 15 ips/ 30 ips

Default:

 10 ips

Important:

•  To apply 60 ips, configure on "[Advanced >] of the 

"Recording setup (All cameras)" on the "Recording 
setup" tab under "REC & event" of "Basic setup".

•  For a camera whose compression method is [MJPEG], 

"10 ips / 15 ips / 30 ips" cannot be selected.

•  If a camera whose compression method is [MJPEG] is 

included, [MJPEG] camera is set to "5 ips" even if "10 
ips / 15 ips / 30 ips" is set by slider bar of frame rate 
setting. You can confirm the current setting value with 
[Advanced >] in Recording setup (All cameras).

[Image quality]

Selects the image quality of recorded images.

NQ (Normal): Standard quality
FQ (Fine): High quality
SF (Super Fine): Super fine quality
XF (Extra Fine): Extra fine quality

Default:

 FQ

Important:

•  For a camera whose compression method is [MJPEG], 

"XF" cannot be set.

•  If a camera whose compression method is [MJPEG] is 

included, [MJPEG] camera is set to "SF" even if "XF" is 
set by slider bar of image quality setting. You can 
confirm the current setting value with [Advanced >] in 
Recording setup (All cameras).

Configure the minimum settings [Easy Start]

 (continued)

Содержание WJ-NX100/2E

Страница 1: ...ual for future use The model number is abbreviated in some descriptions in this manual Installation Guide Network Disk Recorder Model No WJ NX100 2E The Operating Instructions PDF is on the Panasonic...

Страница 2: ...nting 14 3 Connections 15 Connection of cameras a mouse and a PC 15 Connection of monitors 16 How to use the terminals of the ALARM CONTROL 17 ALARM CONTROL terminal on the rear side 17 Connection exa...

Страница 3: ...ding events REC event Advanced setup Configure the settings relating to monitors Monitor Configure the settings relating to network Network Configure the settings relating to the user management User...

Страница 4: ...bout the dedicated software option that receives and displays the event and error information compatible cameras and their versions Refer to the Panasonic support website https security panasonic com...

Страница 5: ...subject to having strong vibration or impact Locations near magnetic field sources such as a television or speakers Locations near the devices that emit large sound and generate vibration by sound pre...

Страница 6: ...the source Grounding Confirm that the wire is connected from the SIGNAL GND terminal to earth ground A grounding connection must be made before connecting the power plug or this product to the main p...

Страница 7: ...changed using the mouse wheel When no operation is made for 10 seconds or more the mouse cursor will be hidden The mouse cursor will be dis played again when the mouse is moved This section explains o...

Страница 8: ...ield A a button This button changes the characters to be entered between capital letters and small letters Next button Changes the keys to be displayed for character entry The displayed keys are chang...

Страница 9: ...etup pages Easy Start button It is possible to configure the minimum settings required to operate the recorder such as date time and cam era registration Basic setup Setup page buttons Each Basic setu...

Страница 10: ...and monitor to this product Turn on the power to launch in the following order Turn on the power of the camera and the monitor Turn on the power of the recorder Register the Registration Key of the re...

Страница 11: ...egister the date time and cameras on Easy Start When it is not necessary to change other default settings it is possible to start operations If necessary perform the detailed settings for each functio...

Страница 12: ...Secure Communication Kit option To use the business intelligence function get the Registration Key of the additional business intelligence license according to the additional business intelligence kit...

Страница 13: ...ion rubber large STEP3 Paste two cushion rubbers small onto the right side of the recorder at the positions shown in the following figure Cushion rubber small Approx 2 cm 13 16 inches Approx 9 cm 3 9...

Страница 14: ...n installing the recorder on a wall the height should be no more than 2 m 6 6 ft Make sure that the minimum pullout strength of the mounting screws is 196 N 20 kgf 44 lbf per screw Select the type of...

Страница 15: ...e or above straight PoE hub Mouse included Network Camera 4 max IP address 192 168 0 x 0 1 250 255 Except the camera s IP address Subnet mask 255 255 255 0 Default gateway 192 168 0 1 IP address 192 1...

Страница 16: ...ut video terminal with a BNC cable locally procured Recorder BNC cable locally procured Sub monitor BNC Main monitor HDMI HDMI cable locally procured Note Use a High Speed HDMI Cable Also when the mai...

Страница 17: ...utput 24 V DC max 200 mA max 2 Alarm input 1 Non voltage make contact input 3 3 V pull up Approx 23 k 3 Alarm input 2 Event action will be performed according to the settings 4 Emergency recording inp...

Страница 18: ...nguage on the setup menu is set to Slave When a signal output from the other device is supplied to the time adjustment I O terminal pin no 1 and the time difference between the recorder and the other...

Страница 19: ...r output Recording error output Signal ground G 7 3 Connections continued Alarm connection example When a signal output from the other device is supplied to the Alarm input 1 terminal pin no 2 or Alar...

Страница 20: ...ed or the camera reset L active Face matching output At an error occurrence until the period selected for Error output duration has passed L active Alarm output The set time on the setup menu L active...

Страница 21: ...lug from disconnection DC jack DC plug DC cable AC power adapter included Power cord included Power plug How to prevent the DC plug from disconnection Secure the DC cable at 5 cm 2 inches to 10 cm 4 i...

Страница 22: ...e recorder during startup Step 2 The administration registration window is displayed on the main monitor Enter an administrator a password and a password confirmation following the instruction on the...

Страница 23: ...istration Key will not be displayed from the next time When turn off the power of the recorder Follow the procedure below to turn off the power Step 1 During recording set Recording mode on Advanced s...

Страница 24: ...e recorder must be rebooted by clicking the Restart button The licenses will not be effective until the recorder is rebooted When the Registration Key of the recorder is registered When the license of...

Страница 25: ...lligence kit To use the secure function click the Setup button of Registration of license Security under the system management screen shown in Step 4 and then enter the registration key of the secure...

Страница 26: ...gistration Order change of the registered camera numbers Recording frame rate image quality Smart coding GOP control and audio Other settings will remain default or will be conformed to the camera set...

Страница 27: ...ge the setting to Off to give the IP addresses automatically When the Cancel button is clicked the top screen of Easy Start the menu to set the date time without applying the camera detection result w...

Страница 28: ...the Camera page the Camera registration tab Operating Instructions PDF Refresh button Obtain the latest camera image after interchanging cameras Exit button Exits the setup menu and returns to the top...

Страница 29: ...ard disk drives is available Note The referenced recording days will be calculated based on the assumption that recording is started on Monday The HDD consumption for the event recording will be exclu...

Страница 30: ...may not be authorized to display the images from cameras Check the user level settings of these users Operating Instructions Part of the displayed image is missing This phenomenon is caused by dispers...

Страница 31: ...tion so as to keep the correct current time HDD indicator lights blinks red The hard disk drive is faulty Contact your dealer The error indicator blinks red A system error occurred Contact your dealer...

Страница 32: ...th a chemical symbol In this case it complies with the requirement set by the Directive for the chemical involved Disposal may be regulated in your community due to environmental considerations For di...

Отзывы: