Error notification
When an error occurs, the setting to send the message to the previously registered addresses is performed.
Up to 3 destinations of notification can be registered.
1
Click the [Event] button on the setup menu.
2
Click the [Error notification] tab.
The "Error notification" window will be displayed.
3
Perform the settings for each item.
Refer to the following for further information about
the settings for each item.
4
Click the [Set] button.
Setup items
■
Error notification
Select "On" or "Off" to determine whether or not to acti-
vate the transmission of error notification.
■
Destination port
Specify the port number to which an error notification is
transmitted when an error occurs.
Default:
8181
■
Retry times
Select the retry number of the transmission to the PC
from the following.
1/2/3 ...29/30
Default:
2
■
Destination address 1 - 3
Specify the address to which an error notification is
transmitted when an error occurs.
However, the following addresses are not available to
register as a destination of error notification.
0.XXX.XXX.XXX/XXX.XXX.XXX.0/XXX.XXX.XXX.255/
127.0.0.1
• Class D address (224.0.0.0 - 239.255.255.255)
• Class E address (240.0.0.0 - 255.255.255.255)
■
Output terminal
Select "On" or "Off" to determine whether or not to pro-
vide the error notification signal output at error occur-
rence with this unit.