9.

Press the mounting plate tightly against the wall and se-
cure to  the outside of the wall sleeve with the supplied
screws(screw II). (Fig. 7)

8.

Using enclosed template (pattern paper), mark and cut
the opening in the interior wall cover. (Fig. 6)

10. Remove the grille from the fan unit.

Press the spring locks on the sides and pull the grille
back. (Fig. 8)

11. Attach the electrical connectors to each other, hook the

frame latches onto the mounting plate latch, and secure
the fan unit to the mounting plate with the supplied screw
(screw III). (Fig 9)

12. Reattach the grille to the frame.

6

Installation I (In new construction) - continue

Fig. 7

Fig. 8

Grille

Fan unit
(Frame)

7.

Insert the attached exterior hood from the outside to cover
the wall sleeve, and secure it with four screws or nails.
Cover the seam between the wall sleeve and exterior
hood with aluminum tape, and apply mortar or caulking
around the exterior hood flange to prevent rainwater from
coming in. (Fig. 5)

Fig. 6

Interior wall
material

Fig. 5

Exterior hood

Finish with mortar
or caulk.

Aluminum
tape

Seam

Mounting plate

Latch

Latch

Fig. 9

Frame

Grille

CAUTION:
Do not pinch the power cord with the frame.

CAUTION:
Press on the grille until it clicks.

NOTE:
Be sure to paint the exterior hood.  Before painting, thor-
oughly wipe off any oil on the surface.  Also make sure that
the paint does not enter inside of the hood.

Содержание Whisper Wall FV-08WQ1

Страница 1: ...uld result in personal injury and or property damage Please retain for future reference Table of Contents Pages List of components 2 Description 2 Reference installation drawing 2 Dimensions 3 Specifications 4 Unpacking 4 General safety precautions 4 Installation I In new construction 5 6 Installation II In remodeling 7 8 Maintenance 9 10 Product Service 10 FV 08WQ1 Ventilating Fan Through the Wal...

Страница 2: ... designed for extended service life with reduced energy consumption It also incorporates a thermal cutoff device for safety The grille is easily detachable from the main unit Interior wall Wall thickness 114 3 152 4 mm 4 5 6 No extension sleeve is used Quantity 1 4 1 2 Quantity 1 1 1 1 Exterior wall Exterior hood Outdoor Flexible conduit Wall sleeve Connector Main unit Indoor When the wall thickne...

Страница 3: ...3 Blade 4 Motor 5 Connector 6 Hook 7 Flange 8 Duct 9 Junction box 10 Junction box cover 11 Connector 12 Shutter 13 Duct 14 Spring 15 Bird screen T U A B C D E F 260 52 88 2 173ø 250 10 1 4 2 1 16 3 15 32 3 32 6 13 16ø 9 27 32 G H I J K L 115 203 240 230 230 260 4 17 32 8 9 7 16 9 1 16 9 1 16 10 1 4 M N O P Q R 204ø 50 50 150 230 240 8 1 32ø 31 32 31 32 5 29 32 9 1 16 9 7 16 S T U 240 207 127 9 7 1...

Страница 4: ...rify that all parts were supplied 1 At 0 0 Static pressure Pa 2 For main unit only WARNING To reduce the risk of fire electric shock or injury to persons observe the following A Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer B Installation work and electrical wiring must be done by qualified person s in accordance with all applicabl...

Страница 5: ...1 Exterior wall Stud 8 1 2 diameter Wiring Diagram 2 Adjust position of the flange on the wall sleeve Fig 2 Loosen the three screws arrow pointed and slide the wall sleeve horizontally to adjust its position to compensate for the thickness of the interior wall A When this has been done tighten all three screws 3 After providing a 3 mm notch in the wall stud secure the flange to the wall stud with ...

Страница 6: ...stallation I In new construction continue Fig 7 Fig 8 Grille Fan unit Frame 7 Insert the attached exterior hood from the outside to cover the wall sleeve and secure it with four screws or nails Cover the seam between the wall sleeve and exterior hood with aluminum tape and apply mortar or caulking around the exterior hood flange to prevent rainwater from coming in Fig 5 Fig 6 Interior wall materia...

Страница 7: ...ring through the wall using a flexible con duit 3 Remove the junction box from the wall sleeve by remov ing two screws C Fig 11 4 Remove the junction box cover by removing screw B 5 Remove the screws D and replace the wall sleeve flange with the mounting flange The mounting plate face should align with the end of the wall sleeve which is protruding from indoor side Installation II In remodeling CA...

Страница 8: ...sition in the wall sleeve and reattach the box cover Fig 15 Installation II In remodeling continued Fig 15 Fig 14 Flexible conduit CAUTION Reattach the junction box cover carefully so that the lead wires are not pinched by the cover Motor White Black Red Green Junction box Power supply AC 120 V 60 Hz Green Earth ground Fig 13 Exterior hood Finish with mortar or caulk Fig 16 CAUTION Press on the gr...

Страница 9: ...ent 3 Do not immerse resin parts in water with temperature higher than 140o F 60o C 1 Remove the grille Hold the grille and press the hooks on each side simultaneously Pull the grille straight out from the wall Fig 17 2 Wash and clean the grille Use non abrasive kitchen de tergent Wipe it dry with a clean cloth Fig 18 Fig 17 Grille Fig 18 3 Remove dust and dirt from the fan blades and body us ing ...

Страница 10: ...roduct is designed and manufactured to ensure a minimum of maintenance However should your unit ever require service a nation wide system of factory service centers and AUTHORIZED INDEPENDENT SERVICE CENTER is maintained to support your product s warranty In the U S A call 1 800 545 2672 to locate the PASC Authorized Service Center nearest you Fig 20 Maintenance continued Blade Fan unit Frame PANA...

Отзывы: