For installer
Menu
Default Setting
Setting Options / Display
Installer setup System setup
1
Optional PCB connectivity
To connect to the external PCB
required for servicing.
No
•
If the external PCB is connected (optional), the system will have following additional functions:
1
Buffer tank connection and control over its function and temperature.
2
Control over 2 zones (including the swimming pool and the function to heat water in it).
3
Solar function (the solar thermal panels connected to either the DHW (Domestic Hot Water) Tank or the Buffer Tank.
4
External compressor switch.
5
External error signal.
6
SG ready control.
7
Demand control.
8
Heat-Cool SW
2
Zone & Sensor
To select the sensors and to
select either 1 zone or 2 zone
system.
Zone
•
After selecting 1 or 2 zone system, proceed to
the selection of room or swimming pool.
•
If the swimming pool is selected, the
temperature must be selected for
T temperature between 2 °C ~10 °C.
Sensor
* For room thermostat, there is a further
selection of external or internal.
3
Heater capacity
To reduce the heater power if
unnecessary.*
3 kW / 6 kW / 9 kW
3 kW
* Options of kW vary depending
on the model.
4
Anti freezing
To activate or deactivate the
water freeze prevention when
the system is OFF
Yes
5
Tank connection
To connect tank to the system.
No
6
Buffer tank connection
To connect tank to the system
and if selected YES, to set
T temperature.
•
The optional PCB connectivity
must be selected YES to
enable the function.
•
If the optional PCB connectivity
is not selected, the function will
not appear on the display.
No
Yes
5 °C
Set T for Buffer Tank