78
16.3. Breakdown Self Diagnosis Function
16.3.1.
Self Diagnosis Function (Three Digits Alphanumeric Code)
• When abnormality occur during operation, the system will stop operation, and OFF/ON remote control LED will blink and error
code will display on the remote control Timer display LCD.
• Even error code is reset by turning OFF power supply or by pressing ERROR RESET button, if the system abnormality is still un-
repaired, system will again stop operation, and OFF/ON remote control LED will again blink.
• The error code will store in IC memory.
•
To check the error code
1. When an abnormality occurs, system will stop operation and OFF/ON remote control LED will blink.
2. Error code of the abnormality will display on the remote control Timer display LCD.
3. To determine the abnormality description, the Error Code Table needs to be referred.
•
To display past/last error code
1. Turn ON power supply.
2. Press and hold the CHECK button for more than 5 seconds to enter status mode.
3. Press the SEARCH DOWN/UP button to retrieve past/last error code.
4. Press the CANCEL button or wait 30 seconds to exit status mode.
•
To permanently delete error code from IC memory
1. Turn ON power supply.
2. Press and hold the ERROR RESET button for more than 8 seconds till a beep sound is heard.
Содержание WH-MDC09C3E5
Страница 14: ...14 4 Location of Controls and Components 4 1 Monobloc Unit ...
Страница 17: ...17 ...
Страница 18: ...18 ...
Страница 19: ...19 4 1 2 2 Weekly Timer Setting ...
Страница 20: ...20 4 1 2 3 Setting Up The Special Functions ...
Страница 21: ...21 5 Dimensions 5 1 Monobloc Unit ...
Страница 22: ...22 6 Refrigeration And Water Cycle Diagram ...
Страница 23: ...23 ...
Страница 24: ...24 7 Block Diagram 7 1 WH MDC09C3E5 ...
Страница 25: ...25 7 2 WH MDC12C6E5 WH MDC14C6E5 WH MDC16C6E5 ...
Страница 26: ...26 8 Wiring Connection Diagram 8 1 WH MDC09C3E5 ...
Страница 27: ...27 ...
Страница 28: ...28 8 2 WH MDC12C6E5 WH MDC14C6E5 WH MDC16C6E5 ...
Страница 29: ...29 ...
Страница 30: ...30 9 Electronic Circuit Diagram 9 1 WH MDC09C3E5 ...
Страница 31: ...31 ...
Страница 32: ...32 9 2 WH MDC12C6E5 WH MDC14C6E5 WH MDC16C6E5 ...
Страница 33: ...33 ...
Страница 34: ...34 10 Printed Circuit Board 10 1 Water System 10 1 1 Main Printed Circuit Board ...
Страница 35: ...35 10 1 2 Solar Printed Circuit Board Optional ...
Страница 36: ...36 10 2 Refrigerant System 10 2 1 Main Printed Circuit Board ...
Страница 37: ...37 10 2 2 Capacitor Printed Circuit Board 10 2 3 Noise Filter Printed Circuit Board ...
Страница 38: ...38 11 Installation Instruction Monobloc Unit Dimension Diagram ...
Страница 39: ...39 Main Components ...
Страница 52: ...52 Solar Priority is Set Solar Priority is Not Set ...
Страница 55: ...55 Heat Tank Heating No Priority Solar Priority Set ...
Страница 56: ...56 Heat Tank Heating No Priority Solar Priority Not Set ...
Страница 66: ...66 Solar Priority Not Set Heat Tank Mode Heating Priority Set ...
Страница 67: ...67 Tank Mode Solar Priority Set Solar Priority Not Set ...
Страница 115: ...115 17 3 To Remove The Cabinet Rear Plate 17 4 To Remove Pressure Gauge 17 5 To Remove RCCB ...
Страница 118: ...118 17 10 To Remove Bottle Complete When reinstall the water pipe use grease or water at the joining ...
Страница 130: ...130 ...
Страница 134: ...134 19 2 WH MDC09C3E5 WH MDC12C6E5 WH MDC14C6E5 WH MDC16C6E5 Water System ...