7
English
Dealer
Operation/settings to be done only by the authorised dealer/specialist.
User
Operation/settings to be done by the authorised dealer/specialist or user.
*
1
The system is locked to operate without COOL mode. It can be unlocked only by authorised installers or our authorised service partners.
*
2
Only displayed when COOL mode is unlocked (Means when COOL mode is available).
User
Control panel preparation
1
Press
.
2
Press or to set the current day.
3
Press to confirm.
4
Repeat steps
2
and
3
to set the current time.
■
Note:
• The current day and time need to be set in cases below:
- When the power is turned on for the first time.
- A long time has elapsed since the power was turned on the
last time.
• The current time that has been set will be the standard time for
all the timer operations.
Caution Indicator (Tank Temperature above 60 °C)
6
Backup Heater For Tank
To activate backup heater during tank operation.
YES
YES
NO
• Do not use the system during sterilisation in order to prevent scalding with hot water, or overheating of shower.
• Ask an authorised dealer to determine the level of sterilisation function field settings according to the local laws and regulations.
7
Sterilisation
To sterilise the water tank, if required.
Note: If NO is selected, menus 8 to 10 are skipped.
YES
YES
NO
8
Sterilisation Day & Time
To set timer for sterilisation.
(Only once a week. Operates even under a standby condition)
Monday
12:00
Monday ~
Sunday
0:00 ~ 23:50
9
Sterilisation Temperature
To set the temperature of sterilisation.
65 °C
40 °C ~ 65 °C
10
Continuation of Sterilisation
To maintain heating temperature in order to complete the sterilisation.
10 minutes
5 minutes ~
1 hour
11
Base Pan Heater
To select whether or not to connect to the optional base pan heater.
Note: If NO is selected, menu 12 is skipped.
NO
YES
NO
12
Base Pan Heater type
Type A - The base pan heater activates only during deice operation.
Type B - The base pan heater activates when outdoor ambient
temperature is 5 °C or lower.
A
A
B
13
*
1,
*
2
Cool Outdoor Temperature setting
To set the outdoor ambient temperature for the AUTO mode to
change from HEAT to COOL.
15 °C
5 °C ~ 25 °C
14
*
1,
*
2
Heat Outdoor Temperature setting
To set the outdoor ambient temperature for the AUTO mode to
change from COOL to HEAT.
10 °C
5 °C ~ 25 °C
15
Dry Concrete
During construction to dry the concrete under a preset temperature.
Do not use this menu for any other purposes and in period other than
during construction (Refer to Information page).
-
1 day ~ 99 days
To
adjust initial settings
F569865-SS1114-0.indb 7
F569865-SS1114-0.indb 7
08/01/2015 12:44:38 PM
08/01/2015 12:44:38 PM
Process Black