Note
After the Control Box is initialised, you must configure the mandatory settings with Quick Setup Wizard.
For details refer to "4.4.1 Quick Setup Wizard".
1.
Slide the System Mode Switch to the "SYSTEM INITIALIZE" position.
A
B
A. STATUS Indicator
B. System Mode Switch
2.
Turn on the power switch of the Control Box. The STATUS indicator will flash green.
3.
While the STATUS indicator is flashing green, slide the System Mode Switch back to the "NORMAL"
position. Depending on the configuration, initialisation takes about 2.5 minutes. If successfully executed,
the STATUS indicator will stop flashing and remain lit up.
3.5 Starting the Control Box
Installation Manual