Thank you for purchasing a Panasonic product.

Please read this guide before using the unit and save for future reference.

© Panasonic Corporation 2017

1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8501, Japan

http://www.panasonic.com

PNQX8620ZA

     

C0917MM1

Installation and Operation Guide

Lobby Station

Model No.

 VL-V591

Contents

Introduction

System component .............................................................2

Included items .....................................................................2

Important Information

For your safety ....................................................................3

Important safety instructions .............................................4

For best performance .........................................................4

Other information ................................................................4

Controls

Location of controls ............................................................5

Installation

Before installation ...............................................................6

Installing the lobby station .................................................7

Wiring schematic diagram ................................................10

Programming

How to program the settings ............................................12

Registering room numbers ..............................................13

Setting the PIN (Personal Identification Number)

 ..........14

Setting the time how long the door remains open .........14

Using the Lobby Station

Calling a room from the lobby station .............................15

Opening the door using the PIN  

   (Personal Identification Number)

 ..................................15

General Information

Cleaning .............................................................................16

Specifications

 ....................................................................16

Other Infomation................................................................16

VL-V591_IG_en.indd   1

2017/09/22   19:02:53

Содержание VL-V591

Страница 1: ...tant safety instructions 4 For best performance 4 Other information 4 Controls Location of controls 5 Installation Before installation 6 Installing the lobby station 7 Wiring schematic diagram 10 Programming How to program the settings 12 Registering room numbers 13 Setting the PIN Personal Identification Number 14 Setting the time how long the door remains open 14 Using the Lobby Station Calling ...

Страница 2: ...L MV30 VL MV71 VL MV72 VL MVN511 VL MWD272 VL MWD273 VL MW274 VL MWD501 The types and number of door stations that can be connected differs depending on the main monitor used Refer to the documentation of your main monitor station Connectable number 1 20 total Note L For details on optional units that can be connected to the main monitor stations see the operating instructions of the main monitor ...

Страница 3: ...connection work should be performed by certified personnel only Certification is required for performing electrical connection work Consult your dealer L Do not install the product in a place where there is high humidity L Do not install the power supply unit in the following places Places where the power supply unit may be splashed with water or chemicals Places where there is a high concentratio...

Страница 4: ...VE THESE INSTRUCTIONS For best performance Before using L When power fails this unit cannot be used Environment L When you leave the unit unused for a long period of time unplug it from the power outlet L The power supply unit should be kept away from heat sources such as heaters etc It should not be placed in rooms where the temperature is less than 0 C or greater than 40 C Damp basements should ...

Страница 5: ...SET switch L To reset the unit if it is not working properly The program settings are not affected Use a pointed object such as a pen to press this switch P BACKLIGHT COMPENSATION switch page 9 Q Speaker volume switch page 9 R Water drain holes L These holes allow rain water to drain Do not cover them N Upper cabinet rear view L The figure below shows the appearance when the lower cabinet is remov...

Страница 6: ...ls Places where there is a high concentration of dust or high humidity Side view when the camera is installed lower than the standard position and facing upwards at 15 Example Installation height is 980 mm 1330 mm 1810 mm Center of main unit 66 650 mm Image range 1160 mm 500 mm Top view Image range 960 mm 500 mm 87 Side view when the camera is facing forwards at 0 default Example Installation heig...

Страница 7: ...riate connector or connection terminal L To prevent the DC cable from disconnecting and to prevent electric shock secure the DC cable using the cable binder accessory and attach the cable cover How to connect the AC cable and DC cable Connect the power supply unit accessory the AC cable accessory and a DC cable locally procured A B Power Supply Unit VL PS241 side 1 25 mm 2 7 mm Lobby Station VL V5...

Страница 8: ...ve the lower cabinet 1 A B D G H DC cable connected to the power supply unit Upper cabinet Lower cabinet Wires connected to rooms and the door opener G Water drain holes Wall 2 Flush mounted box C Screw Screw Screws N Adjusting the camera angle Upper cabinet rear view Upwards maximum 15 Camera angle control lever Downwards maximum 5 Examples of camera angles Facing forwards Facing upwards Facing d...

Страница 9: ... lower cabinet L Tape the cables connected to the upper cabinet to an appropriate position on the upper cabinet to prevent them from becoming pinched between the upper cabinet and lower cabinet Resister room numbers and program other settings page 12 14 Set each main monitor station page 11 Check the connections to the rooms by calling them from the lobby station and opening the door of the common...

Страница 10: ...ively short The door opener is less than 30 V AC 1 A 24 V DC 1 A Do not connect to a door opener that is more than 30 V AC 1 A 24 V DC 1 A otherwise the unit may be damaged K1 K2 terminal on the lobby station is not the power supply to the door opener If the door opener needs a power supply device to connect to the lobby station contact the dealer where you purchased the door opener L After connec...

Страница 11: ...tion change the setting of LOBBY CONNECTION to YES using the main monitor stations Refer to the Operating Instructions of the main monitor stations DOOR KEY setting L Confirm that the door can be properly locked unlocked depending on the status of the door opener The door of the common entrance can be opened by each main monitor station The time how long the door remains open by the door opener ca...

Страница 12: ...L The DOOR OPEN indicator BUSY indicator function as follows while programming Setting status DOOR OPEN indicator BUSY indicator The unit is in programming mode OFF Flashes rapidly The function code is entered You can set the function OFF Flashes slowly The unit is waiting to save the setting Flashes slowly Flashes slowly The setting is being saved Lights for 1 second Flashes slowly Error such as ...

Страница 13: ...ing mode enter 9 9 9 then press CALL Canceling the registration of all room numbers 1 Press and hold the PROGRAM switch for about 2 seconds during standby 2 Enter 0 4 4 then press CALL L ALL and dEL are displayed alternately L To stop deleting numbers press CLR 3 Press CALL to cancel the registration 4 To end programming mode enter 9 9 9 then press CALL Registering room numbers Register each room ...

Страница 14: ...al Identification Number When a separate door opener is connected to the lobby station the PIN is used to open the door of the common entrance The default PIN is 0000 the feature is deactivated Once you change the PIN the door can be opened using the PIN 1 Press and hold the PROGRAM switch for about 2 seconds during standby 2 Enter 0 0 5 then press CALL 3 Enter the 4 digit PIN 0001 9999 L To corre...

Страница 15: ...opened the DOOR OPEN indicator lights L The door opener allows you to open the door for the time specified in Setting the time how long the door remains open page 14 Note L Err Error is displayed when the following occurs The wrong PIN is entered in step 2 Press CLR then start from step 1 again A 5 digit PIN is entered in step 2 Press CLR then start from step 1 again The PIN has not been set page ...

Страница 16: ...th 6 For indoor use only 7 Class P equipment equipment in which protection against electric shock relies on Double Insulation or Reinforced Insulation 8 ON power 9 OFF power 10 Stand by power 11 ON OFF power push push 12 Caution risk of electric shock Information on Disposal in other Countries outside the European Union The symbol 1 is only valid in the European Union If you wish to discard this p...