Screw A

You can use the [Wide/Zoom settings] setting on the main monitor to select the area that 
is visible when a visitor calls; available settings are [Wide], [Zoom], and [All] (entire image 
display). (Default setting: [Wide])

 

● The following values are for when the doorphone is installed in the standard position 

(the centre of the doorphone’s height is approximately 1,450 mm) and at a distance of 
approximately 500 mm from the camera lens.

■ 

Installation height and area visible by the camera lens

When set to zoom

Displays a portion of the wide image at 2 times the size.

 

● Because a digital zoom is used, the image quality of zoom 

display is lower than that of wide display or entire image display.

Image displayed on 

main monitor:

 

● You can use the main monitor’s [Zoom position settings] setting to select the desired area 

visible when zooming. Refer to the following and configure the main monitor.

Entire image display

The area above and below the wide image is visible.

Important:

 

● On the bottom surface of the doorphone and the mounting base, there are holes to allow water 

to drain. Do not cover them up when installing.

 

● When existing wiring (such as chime wires) is used:

 - It may contain AC voltage that may cause electric shock and/or damage the product.
 - Never use the following types of wiring. Consult a qualified technician/dealer.

VL-V554BX

VL-V554UBX

Attach the mounting base to the wall securely.

Mounting base

(accessory)

Wire (locally procured)

Wall

83.5 mm

Screws (accessory) × 2

 

● Install the mounting base on a vertical flat wall.

Install the flush mounting box in the 
wall.

Flush mounting box (accessory)

100 mm

Knockout hole

*1

151 mm

37 mm

*1 Only open the knockout holes as 

required for the wiring.

Use a hex wrench (accessory) to loosen screw A and remove the front panel of the door-
phone.

 

Screw A

Front panel

2 mm hex wrench

 

(accessory)

Connect the wires.

Terminal for the 

main monitor

<

Rear view

>

Terminal for the electric 

lock

●Recommended torque: 

  0.5 N·m {5.1 k

g

f·cm}

●Maximum torque: 

  0.7 N·m {7.1 k

g

f·cm}

3-1

 Loosen the screws.

3-2

 Push in the wires to the terminal connectors (non-polar), then tighten the screws.

Attach the doorphone to the mounting 
base.

Screws (accessory) × 4

Attach the doorphone to the flush mounting 
box.

 

Screws (accessory) × 4

Attach the name plate to the doorphone and use screw A to secure the front panel.

 

● Write the name on the name plate as needed.

 

● Recommended torque: 

0.35 N·m {3.6 k

g

f·cm}

Name plate 

(accessory)

Screw A

Approx. 500

Approx. 170°

Approx. 2,250

Image range

Approx. 115°

Approx. 500

Image displayed on 

main monitor:

Approx. 1,600

Approx. 650

Approx. 1,450

Up and down

Left and right (when looking from above)

Up

Image range

Approx. 2,050

Approx. 500

Centre of 

doorphone

Approx. 45°

Centre (default)

Approx. 45°

Approx. 500

Image range

Approx. 1,650

Down

Approx. 45°

Approx. 500

Approx. 1,400

Image range

Left

Approx. 1,500

Approx. 1,450

Approx. 550

Approx. 1,450

Approx. 1,250

Approx. 400

Installing the doorphone

■ 

About the installation location

 

● The AC cable plug is used as the main disconnect device. Ensure that the power outlet is 

installed near the product and is easily accessible.

 

● A readily accessible disconnect device shall be incorporated external to the equipment.

 - External disconnect device must be certified and have a creepage and clearance distance 

of 3 mm or more.

■ 

Precautions for wiring

 

● Make sure that the power supply unit is unplugged before performing any wiring work.

 

● Always connect AC or DC cables to the appropriate connector or connection terminal.

 

● To prevent the DC cable from disconnecting and to prevent electric shock, secure the DC 

cable using the cable binder (accessory) and attach the cable cover.

How to connect the AC cable and DC cable

Strip the DC cable as follows:

<DC cable>

7 mm

25 mm

Remove the screw (

B

) and then remove 

the cable cover (

A

).

Connect the AC cable (accessory) to the AC 
IN connector on the top of the power supply 
unit. Next, connect the DC cable (locally 
procured) to the DC OUT terminal on the 
bottom of the power supply unit, and then 
secure the wires by tightening the screws.

 

● Recommended torque: 0.45 N·m {4.6 k

g

f·cm}

<Front view>

AC cable

DC cable

Screws

*1

Cable binder (accessory)

Use the cable binder (accessory) to secure 
the DC cable (double-coated area) to the 
power supply unit.

Attach the power supply unit to the wall. 
(

 "Wall mounting", below)

Make sure to replace the cable cover (

A

).

Connect the power supply unit (accessory), the AC cable (accessory), and a DC 

cable (locally procured).

CAUTION

Insert the cables firmly all the way 

into the connector and terminal.

If the cables are not inserted all 

the way, heat may be generated.

*1  Make sure that there are no bare wires 

exposed outside the product.

Screw (

B

)

Cable cover (

A

)

DC OUT terminal 

AC IN connector

<Top view>

<Bottom view>

DC cable 

binder hole

Power supply unit (with cable cover 

removed)

Wall mounting

Attach the power supply unit to the wall securely.

Wall

Screws 
(accessory) × 2

Main monitor installation position

Installing the main monitor

Main monitor 
installation position

82.5 mm

82.7

 mm

Connect the DC cable and wires.

 

● Connect the wires correctly according to "Wiring schematic 

diagram".

Mount the main monitor to the mounting bracket.

3-1

  Line up the tab on the bottom of the bracket with the groove on the main monitor (

A

).

3-2

   Line up the tab on the top of the bracket with the groove on the main monitor, and 

push the main monitor down until it is secure (

B

).

Wall

Attach the mounting bracket to the wall 
securely.

 

● Install the mounting bracket on a vertical 

flat wall.

Remove screw A and then remove the 

terminal cover.

B

  Loosen screw B and push in the wires of 

the DC cable to the terminal connectors 

(non-polar), then tighten the screws.

 

● Recommended torque:

0.8 N·m {8.2 k

g

f·cm}

Use the cable binder (accessory) to 

secure the DC cable (double-coated 
area) to the main monitor.

D

  Make sure to replace the terminal cover.

How to connect the DC cable:

While pressing on the button with a point-

ed object such as a screwdriver, insert 

the wire into the terminal connector. (To 

disconnect a wire, while pressing on the 

button, pull out the wire.)

Bare wire at tip

9 mm

Terminal Button

Wiring from 

doorphone

Important:

Do not connect the power cable. 

(Damage may occur.)

How to make wiring connections:

Reset button

SD card 
slot

20 cm

20 cm

20 cm

20 cm

Cable binder 

(accessory)

12 mm

Bare wire at tip

Screw B

■ 

About the installation position of the main monitor and mounting bracket

 

● For the following reasons, leave at least 20 cm of space 

above, below, and to the left and right sides of the main 
monitor:

 - To prevent malfunction and sound cutting out
 -  To ensure SD cards can be inserted and removed, 

and to make sure the reset button can be used  
( the SD card slot is on the side of the main monitor; 

the reset button is on the bottom)

 

● Place the main monitor in a location that your eyes are the same height as the centre 

of the display.

 

● After deciding where to install the main monitor, attach 

the mounting bracket in the location shown on the 
right.

Doorphone installation position

Installing the power supply unit

Image range: 

Approx. 900

Approx. 500

Approx. 85°

Approx. 170°

Centre (default)

Image range: 

Approx. 900

Approx. 85°

Right

Image range: 

Approx. 900

Approx. 500

Approx. 170°

Approx. 85°

Approx. 500

Approx. 850

Approx. 1,450

Approx. 550

32 mm

When set to wide (default)

Centre of 

doorphone

Centre of 

doorphone

Centre of 

doorphone

Approx. 95°

Centre of 

doorphone

Approx. 1,450

Approx. 500

Approx. 900

Approx. 170°

Approx. 500

Approx. 1,100

Approx. 2,000

Image range

Image displayed on 

main monitor:

View when looking 

from above

View when looking 

from above

(Units: mm)

Notes about electrical wiring

Make sure not to pinch the wires (as shown to the 
right) on the mounting bracket when installing.

 

● Do not forcibly attach to the mounting bracket.

Vertical, flat wall

Screws
(accessory)

Hole in wall

83.5

60

7

50

Mounting bracket

(Units: mm)

(Units: mm)

(Units: mm)

(Units: mm)