Main monitor installation
position

About the installation position of the main
monitor and mounting bracket

R

Place the main monitor in a location that your
eyes are the same height as the centre of the
display.

R

For the following reasons, leave at least 20 cm
(

A

) of space above, below, and to the left and

right sides of the main monitor:
– To prevent malfunction and sound cutting out
– To ensure to make sure the reset button (

B

)

can be used (the reset button is on the
bottom of the main monitor)

1

1

1

2

1

R

After deciding where to install the main monitor,
attach the mounting bracket in the location
shown below.

D

E

C

C

 Main monitor installation position

D

 80.5 mm

E

 86.8 mm

Installing the main monitor

1

Attach the mounting bracket (

A

) to the wall

securely.

R

Install the mounting bracket on a vertical flat
wall (

B

).

A

B

C

D

E

F

G

H

C

 Screws (accessory)

D

 Hole in wall 

E

 60 mm 

F

 83.5 mm

G

 7 mm 

H

 50 mm

2

Connect the DC cable and wires.

R

Connect the wires correctly according to
"Wiring schematic diagram".

2-1 How to connect the DC cable

A

 Remove screw A (

A

) and then remove the

terminal cover.

B

 Loosen screw B (

B

) and push in the wires

of the DC cable to the terminal connectors
(non-polar), then tighten the screws.

R

Recommended torque: 0.8 N·m {8.2 kgf·cm}

C

 Use the cable binder (

E

) (accessory) to

secure the DC cable (double-coated area) to
the main monitor.

D

 Make sure to replace the terminal cover.

1

2-1

2-2

E

C

D

B

Bare wire at tip

C

 7 mm 

D

 30 mm

13

Содержание VL-SVN511 Series

Страница 1: ... Note to the installer R Before attempting to connect or operate this product please read the label on the rear of the doorphone and the main monitor R Please read this guide carefully and install the product safely and correctly by following the instructions Carefully read the information found in the section titled For your safety in particular R Only use attachments accessories specified by the...

Страница 2: ...shed with water or chemicals Places where there is a high concentration of dust or high humidity R Do not perform any actions such as fabricating twisting stretching bundling forcibly bending damaging altering exposing to heat sources or placing heavy objects on the power cable that may damage the power cable Using the product with a damaged power cable may cause electric shock short circuits or f...

Страница 3: ... Power supply unit 1 VL PS240 Cable binder 2 Power supply unit 1 VL PS241 AC cable 1 Screw 2 4 mm 40 mm Important R You will need the following additional items to install and configure the doorphone and the main monitor Locally procured Power cables AC DC cables wires for doorphone and other connections Prepare cables and wires of the appropriate specification a Wire type and length Note R The il...

Страница 4: ... s lens cover This may cause images to become obscured Condensation will dissipate as the temperature rises For the main monitor R Install the main monitor away from electronic appliances such as TVs radios personal computers air conditioners boiler control panels with intercom home security equipment wireless devices or digital cordless phones R Do not install the main monitor in places where it ...

Страница 5: ... 5 6 R1 R2 7 8 R3 IN1 9 10 IN2 IN3 11 12 IN4 P1 13 P2 R1 1 R2 R3 S2 1 S1 S4 2 S3 2 You can also connect an optional lobby station for apartment complexes Connecting an optional lobby station see page 7 A Power supply 1 VL MVN511 models The doorphone is optional not included 2 VL MVN511 models only 3 VL SVN511 models Use only the supplied AC cable 4 VL MVN511 models The relay box is optional not in...

Страница 6: ... 100 m 1 Type Single pair cable with outer sheath jacket Conductor Copper solid R A certified power supply wiring has to be used with this equipment The relevant national installation and or equipment regulations shall be considered A certified power supply wiring not lighter than ordinary polyvinyl chloride flexible wiring according to IEC 60227 shall be used 2 When using an electric lock or a co...

Страница 7: ... proper operation Connect terminal D1 D2 on the main monitor with terminal D1 D2 on the lobby station Connect terminal R1 R2 on the main monitor with terminal R1 R2 on the Relay box Connect terminal S1 S2 on the Relay box with terminal S1 S2 on the lobby station After connecting to the main monitor change the Lobby connection setting to Connected devices using the main monitor Operating Instructio...

Страница 8: ...e doorphone step 3 Installing the doorphone so that the image range can be changed Side view when the camera is installed lower than the standard position and facing upwards at 15 Top view when the camera is facing left or right at 15 1 R Example Installation height is 1100 mm Units mm R Example Camera angle faces left 15 A B C D E F G H I J K L M A Image range B Approx 66 C Centre of doorphone D ...

Страница 9: ...rials 1 Remove the mounting base Open the screw cover A A B B Screwdriver Loosen the mounting screw C C D E D Water drain holes E Mounting base 2 Attach the mounting base A to the wall securely using the wood screws B accessory R Install the mounting base on a vertical flat wall R Before drilling refer to Precautions for installation for installation location A B C D 1 C Wire locally procured D 83...

Страница 10: ... right the image may be slightly distorted 4 Connect the wire then mount the doorphone to the mounting base Unscrew the screws Push in the wire to the terminal connectors non polar then tightly fasten the screws A A Recommended torque 0 5 N m 5 1 kgf cm Maximum torque 0 7 N m 7 1 kgf cm A B B Wire connecting to the main monitor Mount the doorphone to the mounting base Fasten the screw then close t...

Страница 11: ...e 1 Do not connect the AC cable and DC cable inversely That would be a cause of malfunctions Make sure that there are no bare wires exposed outside the product Power supply unit with cable covers removed Top view Bottom view L M J K L AC cable binder hole M DC cable binder hole 1 Strip the AC DC cables as follows AC cable A C DC cable B C 2 Remove the screws D and then remove the cable covers E 3 ...

Страница 12: ...cessory the AC cable accessory and a DC cable locally procured A B A 25 mm B7 mm Front view C D E F G H 1 1 Make sure that there are no bare wires exposed outside the product Power supply unit with cable cover removed Top view Bottom view K I J K DC cable binder hole 1 Strip the DC cables as follows DC cable A B 2 Remove the screws C and then remove the cable cover D 3 Connect the AC cable E acces...

Страница 13: ... Main monitor installation position D 80 5 mm E 86 8 mm Installing the main monitor 1 Attach the mounting bracket A to the wall securely R Install the mounting bracket on a vertical flat wall B A B C D E F G H C Screws accessory D Hole in wall E 60 mm F 83 5 mm G 7 mm H 50 mm 2 Connect the DC cable and wires R Connect the wires correctly according to Wiring schematic diagram 2 1 How to connect the...

Страница 14: ...1 2 1 2 S1 S2 S3 S4 9 button 8 6 k 7 Relay box with cable cover removed Top view Bottom view j l m L Cable binder hole 1 Strip the cables from main monitor A and cable from electric lock B C 2 Remove the screw D and then remove the cable cover E 3 Connect the cables from the electric lock F G if 2 electric locks are connected to the electric lock terminal J on the top of the relay box and then sec...

Страница 15: ...15 Notes ...

Страница 16: ...1 62 4 chome Minoshima Hakata ku Fukuoka 812 8531 Japan http www panasonic com Panasonic System Networks Co Ltd 2015 PNQX7569ZA C0915MM0 ...

Отзывы: