background image

6

Wire type and length

*1 Type: Single-pair cable with outer sheath (jacket)

Conductor: Copper solid

R

A certified power supply wiring has to be used with this equipment. The relevant national 
installation and/or equipment regulations shall be considered. A certified power supply wiring not 
lighter than ordinary polyvinyl chloride flexible wiring according to IEC 60227 shall be used.

*2 When an extension monitor is used, make sure that the total wiring length from the doorphone to the 

main monitor and then to the extension monitor, is within about 100 m.

*3 When using an electric lock or a connection device for option input (A contact), select a device that 

meets the following guidelines:

R

Electric lock connection terminal (S1/S2):
– N/O dry closure contact
– 30 V AC (1 A)/24 V DC (1 A) or lower

R

Connection device for option input (A contact) terminal (IN1/IN2/IN3/IN4):
– Input method: No-voltage contact
– Open-circuit voltage between terminals: DC 7 V or less
– Detection definite time: 0.1 second or more
– Short-circuit between terminals: 5 mA or less
– Resistance value: make: 500 

Ω

 or less, break: 15 K

Ω

 or more

Wiring run

Wire type

*1

Diameter

Length (Max.)

Doorphone –

Main monitor –

Extension monitor

*2

ø 0.65 mm

22 AWG

100 m

ø 1.0 mm

18 AWG

130 m

ø  0.5 mm

CAT  5

50 m

Main monitor –

Power supply unit

ø 0.65 mm

22 AWG

10 m

ø 1.0 mm

18 AWG

20 m

Main monitor –

Electric lock

*3

ø 0.5 mm - ø 1.2 mm

(24 AWG - 17 AWG)

According to the 

specifications of the 

connected device.

Main monitor –

Connection device for 

option input (A contact)

*3

ø 0.5 mm - ø 1.2 mm

(24 AWG - 17 AWG)

According to the 

specifications of the 

connected device.

Main monitor –

PBX

ø 0.65 mm

CAT 3 or 22 AWG

100 m

prj_6905-en_gb.book  Page 6  Monday, April 24, 2017  6:10 PM

Содержание VL-SV71

Страница 1: ...please read the label on the rear of the doorphone and the main monitor extension monitor R Please read this guide carefully and install the product safely and correctly by following the instructions...

Страница 2: ...RDo not make any wiring connections when the power supply is turned on RDo not use the supplied power supply unit for outdoor installations it is for indoor use only RDo not install the main monitor e...

Страница 3: ...ations in the supplied manual s may vary slightly from the actual product 1 VL SV71 VL SV72 models only 2 VL SV72 VL MV72 models only For the doorphone 1 Screw 2 3 8 mm 20 mm For the main monitor exte...

Страница 4: ...place the doorphone in locations where echoing occurs as this will cause the doorphone to beep frequently R Make sure the rear of the doorphone is not subject to water R Depending on the installation...

Страница 5: ...series Video Intercom System for Apartment Complexes is used Make sure to connect emergency terminals to the IN1 IN2 terminals Make sure to connect doorbells to the IN3 IN4 terminals A doorbell and do...

Страница 6: ...dry closure contact 30 V AC 1 A 24 V DC 1 A or lower R Connection device for option input A contact terminal IN1 IN2 IN3 IN4 Input method No voltage contact Open circuit voltage between terminals DC 7...

Страница 7: ...onitor Operating Instructions of the Video Intercom System R Connection for VL V900 and VL V700 series Video Intercom System for Apartment Complexes Connect terminal D1 D2 on the main monitor with ter...

Страница 8: ...L Approx 87 M Approx 500 1 If the camera points 15 upwards the left or right angle is less than 7 Note The measurements and angles are for reference purposes and may vary depending on the environment...

Страница 9: ...ase A Open the screw cover A B Screwdriver B Loosen the mounting screw C D Water drain holes E Mounting base 2 Attach the mounting base A to the wall securely using the wood screws B accessory R Insta...

Страница 10: ...e mounting base A Unscrew the screws Push in the wire to the terminal connectors non polar then tightly fasten the screws A B Wire connecting to the main monitor B Mount the doorphone to the mounting...

Страница 11: ...le accessory and a DC cable locally procured A 25 mm B7 mm 1 Make sure that there are no bare wires exposed outside the product K DC cable binder hole 1 Strip the DC cables as follows DC cable A B 2 R...

Страница 12: ...height as the centre of the display R For the following reasons leave at least 20 cm A of space above below and to the left and right sides of the main monitor extension monitor To prevent malfunctio...

Страница 13: ...VL SV72AZ and VL MV72AZ models Connect the DC cable and wires R Connect the wires correctly according to Wiring schematic diagram 2 1 How to connect the DC cable A Remove screw A A and then remove th...

Страница 14: ...or 3 2 Line up the tab on the top of the bracket with the groove on the main monitor extension monitor and push the main monitor extension monitor down until it is secure Notes about electrical wiring...

Страница 15: ...Panasonic Corporation 2017 PNQX8541ZA C0517MM0 1006 Oaza Kadoma Kadoma shi Osaka 571 8501 Japan http www panasonic com prj_6905 en_gb book Page 16 Monday April 24 2017 6 10 PM...

Отзывы: