3. Features
2. Features
2-8. E-lock & Access Control
It is possible to integrate with Access Control and E-lock.
■
Wiring schematic (VL-VM101)
(Access Control, E-lock & Lobby Station)
Electrical
Lock
Access Control
/Card Reader
(Outside)
Electrical
Lock
Access Control
/Card Reader
(Outside)
2 (N/P)
K-OUT
K-OUT
S1 and S2: Normally-Open (Active Close)
S2 and S3: Normally-Close (Active Open)
Wiring
Schematic
K-IN
2 (N/P)
Switch
(Inside)
K-IN
C1 and C2: Access Controller(input)
C3 and C4: Open Door sensor(input)
DC-IN
L-IN
L1 L2
DIP
SW
K-OUT
To AC power
outlet
Open Door sensor (Input)
To Distributor
Power
Supply
K-IN
2 (N/P)