1
2
D1
D2
3
4
D3
D4
5
6
R1
R2
7
8
R3
IN1
9
10
IN2
IN3
11
IN4
12
P1
13
P2
Power
supply
Power
supply
DOORPHONE 1* DOORPHONE 2*
MAIN MONITOR
POWER SUPPLY UNIT
24 V DC
NP
NP
NP
NP
NP
NP
Electric lock
Electric lock
220-240 V AC
Connection device
for option input
(A contact)
Terminal box
(4-conductor
wiring)
PBX*
3
12 V AC/DC
12 V AC/DC
NP
NP
RELAY BOX
A
B
C
D
E
F
G
R1
1
R2
R3
S2
1
S1
S4
2
S3
2
Key Features
• Smartphone Connect:
You can use your smartphone or tablet as a sub monitor to respond to visitors and unlock electric locks no matter where you are in the
home. You can also monitor doorphone images when you want to check the door entrance. Maximum of 4 supported smartphones/tablets can be connected.
* The main monitor must be on the same home Wi-Fi network as a smartphone/tablet (with the dedicated app installed).
* It is also necessary to run the dedicated app in order to receive visitor's calls on a smartphone/tablet.
* Compatible mobile devices: iPhone 5 and later and iPad (iOS 7.0 or later) / Android
TM
smartphones and tablets (Android 4.0 or later)
* Some mobile devices may not be compatible.
* For the latest information about the app and compatible devices, visit the following website.
http://panasonic.net/pcc/support/intercom/smartphone/
• E-mail Notification:
The main monitor can send e-mail with a time stamp and image of visitors to e-mail addresses registered in advance, enabling you to
check who has visited when you are outside the house (even when you are overseas).
When commercially available sensors (such as a fire alarm, calling button, etc.) are connected to the main monitor, you can receive notifications.
* To use this function, a main monitor with e-mail sender information registered must be connected to the internet.
* E-mail may not be able to be sent depending on the condition of the network.
• Wi-Fi Connection:
In addition to smartphones/tablets, the main monitor can also wirelessly connect to the Wi-Fi router for easy connections without a cable.
You can configure Wi-Fi settings using a simplified method (called WPS).
• Electric Lock Release Support:
The gate or door lock can be easily and quickly unlocked with either the main monitor or a mobile device such as a
smartphone/tablet, even from the second floor of the house.
• Picture Recording Function:
The Main Monitor records the images of up to 400 (50 visitors, 8 shots per visitor).
• Wide-Angle Camera:
Wide-angle lens covers approximately 170 degrees horizontally and 130 degrees vertically.
• Voice Change Function:
This function makes woman’s voice (higher keys) sounds like a man’s (lower keys).
• Night Vision:
Door Station is equipped with LED lights (illumination lamp). It enables the colour display of visitors at a distance of about 50 cm at night.
Wiring schematic diagram
Accessory Information
Optional Accessories
VL-SVN511AZ
Video Intercom System
Door Station
(Doorphone)
CMOS 0.3 M pixels
VL-V555
(Surface mount)
Lobby Station
VL-V590
Door Station
(Doorphone)
CMOS 1.0 M pixels
VL-V554
(Surface mount)
VL-V554U
(Flash mount)
For the Door Station:
Mounting base × 1, Screw (4 mm x 12 mm) × 4,
Screw (3.8 mm x 20 mm) x 2, Name plate × 2, Hex wrench × 1
Relay Box and Related Items:
Relay box × 1, Cable binder × 1, Screw (4 mm x 40 mm) x 2
For the Main Monitor Station:
Mounting bracket × 1, Cable binder × 2, Screw (4 mm x 16 mm) x 2,
Power supply unit (VL-PS241) × 1, AC cable x 1, Cable binder x 1,
Screw (4 mm x 40 mm) x 2
Wire type and length
*1 Type: Single-pair cable with outer sheath (jacket)
Conductor: Copper solid
• A certified power supply wiring has to be used with this equipment. The relevant national
installation and/or equipment regulations shall be considered. A certified power supply wiring
not lighter than ordinary polyvinyl chloride flexible wiring according to IEC 60227 shall be used.
*2 When using an electric lock or a connection device for option input (A contact), select a
device that meets the following guidelines:
• Electric lock connection terminal (S1/S2, S3/S4):
– N/O dry closure contact
– 12 V AC/DC, less than 1 A
• Connection device for option input (A contact) terminal (IN1/IN2/IN3/IN4):
– Input method: No-voltage contact
– Open-circuit voltage between terminals: DC 7 V or less
– Detection definite time: 0.1 second or more
– Short-circuit between terminals: 5 mA or less
– Resistance value: make: 500 Ω or less make, break: 15 KΩ or more
*3 Connectable PBX Model Numbers:
KX-TDA30/100/100D/200/600 series, KX-TDE100/200/600 series,
KX-NS300/500/700/1000 series
Please consult your dealer when connecting with a PBX.
*Flash mounting box (VL-MB554) is sold separately.
Up to 20 main monitors can be
connected.
*When you use an additional doorphone, the maximum number of the electric locks that can be connected
to the doorphone depends on the type of doorphone. Consult your dealer for further information.
Wiring run
Wire type
*1
Diameter
Length (Max.)
Main monitor – Doorphone
(including lobby station)
A
φ
0.65 mm
22 AWG
100 m
φ
1.0 mm
18 AWG
130 m
φ
0.5 mm
CAT 5
50 m
Main monitor – Power supply unit
B
φ
0.65 mm
22 AWG
10 m
φ
1.0 mm
18 AWG
20 m
Power supply unit – AC power source
C
φ
1.2 mm -
φ
2.0 mm (17 AWG - 12 AWG)
No requirement
Main monitor – Relay box
D
φ
0.65 mm
22 AWG
100 m
φ
1.0 mm
18 AWG
130 m
Relay box –Electric lock
*2
E
φ
0.5 mm -
φ
1.2 mm (24 AWG - 17 AWG) According to specification of connected device.
Main monitor – Connection device for option input (A contact)
*2
F
φ
0.5 mm -
φ
1.2 mm (24 AWG - 17 AWG) According to specification of connected device.
Main monitor – PBX
G
φ
0.65 mm
CAT 3 or 22 AWG
100 m