background image

Wire type and length

Wiring run

Wire type 

*1

Diameter

Length (Max.)

Main monitor –

Doorphone

(including lobby station)

A

ø 0.65 mm

22 AWG

100 m

ø 1.0 mm

18 AWG

130 m

ø 0.5 mm

CAT 5

50 m

Main monitor –

Power supply unit

B

ø 0.65 mm

22 AWG

10 m

ø 1.0 mm

18 AWG

20 m

Power supply unit –

AC power source

C

ø 1.2 mm – ø 2.0 mm

(17 AWG – 12 AWG)

No requirement

Main monitor –

Relay box

D

ø 0.65 mm

22 AWG

100 m

ø 1.0 mm

18 AWG

130 m

Relay box –

Electric lock 

*2

E

ø 0.5 mm – ø 1.2 mm

(24 AWG – 17 AWG)

According to
specification of
connected device.

Main monitor –

Connection device for

option input (A contact) 

*2

F

ø 0.5 mm – ø 1.2 mm

(24 AWG – 17 AWG)

According to
specification of
connected device.

Main monitor –

PBX

G

ø 0.65 mm

CAT 3 or 22 AWG

100 m

*1 Type: Single-pair cable with outer sheath (jacket)

Conductor: Copper solid

R

A certified power supply wiring has to be used with this equipment. The relevant national
installation and/or equipment regulations shall be considered. A certified power supply wiring not
lighter than ordinary polyvinyl chloride flexible wiring according to IEC 60227 shall be used.

*2 When using an electric lock or a connection device for option input (A contact), select a device that

meets the following guidelines:

R

Electric lock connection terminal (S1/S2, S3/S4):
– N/O dry closure contact
– 12 V AC/DC, less than 1 A

R

Connection device for option input (A contact) terminal (IN1/IN2/IN3/IN4):
– Input method: No-voltage contact
– Open-circuit voltage between terminals: DC 7 V or less
– Detection definite time: 0.1 second or more
– Short-circuit between terminals: 5 mA or less
– Resistance value: make: 500 

W

 or less make, break: 15 K

W

 or more

6

Содержание VL-MVN511

Страница 1: ...s necessary Note to the installer R Before attempting to connect or operate this product please read the label on the rear of the doorphone and the main monitor R Please read this guide carefully and install the product safely and correctly by following the instructions Carefully read the information found in the section titled For your safety in particular R Only use attachments accessories speci...

Страница 2: ...shed with water or chemicals Places where there is a high concentration of dust or high humidity R Do not perform any actions such as fabricating twisting stretching bundling forcibly bending damaging altering exposing to heat sources or placing heavy objects on the power cable that may damage the power cable Using the product with a damaged power cable may cause electric shock short circuits or f...

Страница 3: ...u will need the following additional items to install and configure the doorphone and the main monitor Locally procured Screws for mounting base 2 for mounting bracket 2 for relay box 2 3 Prepare the screws athe drawing on the right according to the material structure strength and other factors of the mounting area and the total weight of objects to be mounted 4 mm Power cables AC DC cables wires ...

Страница 4: ...o water R Depending on the installation location condensation may form on the doorphone s lens cover This may cause images to become obscured Condensation will dissipate as the temperature rises For the main monitor R Install the main monitor away from electronic appliances such as TVs radios personal computers air conditioners boiler control panels with intercom home security equipment wireless d...

Страница 5: ...P Non polarised 12 V AC DC 12 V AC DC NP NP PBX RELAY BOX A E B C D F G 1 2 D1 D2 3 4 D3 D4 5 6 R1 R2 7 8 R3 IN1 9 10 IN2 IN3 11 12 IN4 P1 13 P2 R1 1 R2 R3 S2 1 S1 S4 2 S3 2 1 You can also connect an optional lobby station for apartment complexes Connecting an optional lobby station see page 7 A Power supply 1 VL SVN511AZ models only 2 VL SVN511EX FX models only 3 VL SVN511 AZ models Use only the ...

Страница 6: ... 100 m 1 Type Single pair cable with outer sheath jacket Conductor Copper solid R A certified power supply wiring has to be used with this equipment The relevant national installation and or equipment regulations shall be considered A certified power supply wiring not lighter than ordinary polyvinyl chloride flexible wiring according to IEC 60227 shall be used 2 When using an electric lock or a co...

Страница 7: ... sure to perform the following to ensure proper operation Connect terminal D1 D2 on the main monitor with terminal D1 D2 on the lobby station Connect terminal R1 R2 on the main monitor with terminal R1 R2 on the Relay box Connect terminal S1 S2 on the Relay box with terminal S1 S2 on the lobby station After connecting to the main monitor change the Lobby connection setting to Connected devices usi...

Страница 8: ...00 mm away from the camera lens When set to wide default Units mm A B G F C H E D I J A view when looking from above Image displayed on main monitor A Image range B Approx 130 C Centre of doorphone D Approx 1450 E Approx 500 F Approx 2500 G Approx 2100 H Approx 400 I Approx 170 J Approx 500 When set to zoom Displays a portion of the wide image at 2 times the size R The zoom feature uses a digital ...

Страница 9: ...Approx 100 D Approx 170 Centre default Centre default C D G H F B A E A B C A Image range B Approx 80 C Center of doorphone D Approx 1450 E Approx 500 F Approx 1900 G Approx 900 H Approx 1000 A Image range Approx 1300 B Approx 500 C Approx 105 Down Right C D G B H A E F A B C D A Image range B Approx 80 C Center of doorphone D Approx 1450 E Approx 500 F Approx 1600 G Approx 1200 H Approx 400 A Ima...

Страница 10: ...g materials 1 Attach the mounting base B accessory to the wall securely R Install the mounting base on a vertical flat wall A B C D 1 A Screws locally procured 2 VL SVN511AZ VL V555BX SX VN models included C Wire locally procured D 83 5 mm 1 To prevent dew condensation fill a hole for wiring as much as possible When using mounting box option Model No VL MB554 Install the flush mounting box A in th...

Страница 11: ... 7 1 kgf cm 4 Attach the doorphone to the mounting base A Screws accessory 4 When using mounting box option Model No VL MB554 Attach the doorphone to the flush mounting box A A Screws accessory 4 5 Attach the name plate A accessory to the doorphone and use screw A B to secure the front panel R Write the name on the name plate as needed A B B Recommended torque 0 35 N m 3 6 kgf cm 11 ...

Страница 12: ...able 1 Do not connect the AC cable and DC cable inversely That would be a cause of malfunctions Make sure that there are no bare wires exposed outside the product Power supply unit with cable covers removed Top view Bottom view L M J K L AC cable binder hole M DC cable binder hole 1 Strip the AC DC cables as follows AC cable A C DC cable B C 2 Remove the screws D and then remove the cable covers E...

Страница 13: ...able accessory and a DC cable locally procured A B A 25 mm B7 mm Front view C D E F G H 1 1 Make sure that there are no bare wires exposed outside the product Power supply unit with cable cover removed Top view Bottom view K I J K DC cable binder hole 1 Strip the DC cables as follows DC cable A B 2 Remove the screws C and then remove the cable cover D 3 Connect the AC cable E accessory to the AC I...

Страница 14: ...tallation position D 80 5 mm E 86 8 mm Installing the main monitor 1 Attach the mounting bracket A to the wall securely R Install the mounting bracket on a vertical flat wall B A B C D E F G H C Screws locally procured VL SVN511AZ models included D Hole in wall E 60 mm F 83 5 mm G 7 mm H 50 mm 2 Connect the DC cable and wires R Connect the wires correctly according to Wiring schematic diagram 2 1 ...

Страница 15: ...1 2 1 2 S1 S2 S3 S4 9 button 8 6 k 7 Relay box with cable cover removed Top view Bottom view j l m L Cable binder hole 1 Strip the cables from main monitor A and cable from electric lock B C 2 Remove the screw D and then remove the cable cover E 3 Connect the cables from the electric lock F G if 2 electric locks are connected to the electric lock terminal J on the top of the relay box and then sec...

Страница 16: ...1 62 4 chome Minoshima Hakata ku Fukuoka 812 8531 Japan http www panasonic com Panasonic System Networks Co Ltd 2015 PNQP1255ZA C1015MM0 ...

Отзывы: