2016 Video Intercom

INSTALLATION

GUIDE

Содержание VL-MV26

Страница 1: ...2016 Video Intercom INSTALLATION GUIDE ...

Страница 2: ...omparison chart 2 12 Apartment mode or Housing mode INDEX 3 Wiring 3 1 Basic System Example 3 2 Basic System Configuration 3 3 Large System Example 3 4 Large System Configuration 3 5 Cable Information 3 6 Wiring type and length 3 7 Distance How to use Repeater 3 8 Distribution Box switch settings 3 9 Lift Controller VL V702 3 10 Lift Controller settings Relay control 3 11 Lift Controller Configura...

Страница 3: ...device 6 Operation 6 1 Lobby station operations 6 2 Facility staff operations P54 P55 P60 P61 P62 P63 P64 P65 P66 P67 P68 P69 P70 P71 P74 P75 INDEX 10 Appendix 10 1 VL V900 Series Specifications 10 2 Installing the Power Supply Unit VL PS240 10 3 Expanded system example 10 4 System Diagram of the Apartment System P76 P79 P81 7 Replace 7 1 Replace from Cat 5e Cable IP System 7 2 Replace from Cat 5e...

Страница 4: ...Why Choose a Panasonic Video Intercom System 1 ...

Страница 5: ...t This wide angle camera allows broad lobby areas to be securely monitored Linked Functionality with Security Cameras and SD Recording Functions In addition to providing linked functionality with security cameras up to 90 000 images of visitors can be recorded on an SD card Easy Installation and configuration Easy and low cost installation with 2 wire cables The use of PC setup tools also shortens...

Страница 6: ...Role Features Installation 1 2 ...

Страница 7: ...511 MW251 MV26 Role Features Installation Lift Controller VL V702 2 Electric Locks PBX Terminals Security Camera TV Monitor 1 unit 1 unit 4 units Up to 1 per lobby station up to 3 lobby stations 1 unit Control Box Distribution Box Lobby Station Main Monitor 1 unit 28 units 3 units w o Extension Box 18units with Extension Box 560 units Total System 6 Extension Box VL V703 ...

Страница 8: ...V900 Lift Controller VL V702 Main Monitor VL MVN511 MW251 MV26 Distribution Box VL V701 Monitor Lobby Station or Security Camera Open E Lock Control Lift Call Talk Save Images Logs Security Camera E LOCK LIFT SD PBX Monitor Press 10key Up to 3 units Up to 560 room units total Terminal E LOCK Extension Box VL V703 Lobby Station Extend Up to 18 Lobby Station ...

Страница 9: ...ide angle camera Horizontally 170 vertically 115 Industry average Approx 90 Almost the full width is visible Approx 170 Industry average Approx 70 Approx 115 The face can be seen regardless of height and posture Upper lower angle Vertically Left right angle Horizontally comparison image Equipped with White LED light VL V900 1 0M pixel White LED lights White coloured LED lights for night color visi...

Страница 10: ...default camera view Wide or 9 Zoom position by using Setup Tool Wide View Features View Angles Wide Zoom and Pan Tilt Zoom View Select 9 position Change camera view Wide Zoom and Pan Tilt Change the view by MENU Select Zoom view of 9 position by Position Guide 01 02 03 04 05 06 07 08 09 ...

Страница 11: ...s of the flush mount box and then pass all necessary cables and wires DC cable wires for control box access controller electric lock etc through the knockout holes Step 2 Step 3 Mount the box in the wall Note the drilling dimensions of the wall surface of the flush mount box 2 2 Lobby Station VL V900 Installing the Lobby Station ...

Страница 12: ...DC cable from power supply unit 3 Hooks for securing the DC cable 4 Coaxial cable from external camera 5 Wires from control box 6 Wires from access controller 7 Wires from electric lock 8 Wire release button 9 Connection terminal 1 2 3 4 5 6 7 8 9 Image range Approx 115 1 500 mm 700 mm 1 600 mm 2 300 mm 500 mm Centre of the camera lens Side view Step 5 2 2 Lobby Station VL V900 Installing the Lobb...

Страница 13: ...tation Category Meaning POWER GREEN ACCESS RED Idle Lit Off Call or monitoring in progress Lit Lit Accessing SD card Lit Flashing quickly System setup PC programming in progress Lit Lit PC connection check in progress Lit Lit Error Duplicate distribution box number found Off Flashing slowly Duplicate lift controller number found Off Flashing slowly Normal operation Role of the VL V700 12 ...

Страница 14: ...or Duplicate distribution box number found Off Flashing slowly Duplicate lift controller number found Off Flashing slowly Normal operation 1 Power indicator POWER 2 Access indicator ACCESS 3 Connection terminals for lobby stations 4 Connection terminals for lift controllers 5 USB port underneath dust cover Used for PC programming 6 SD card slot Used to save the system log 7 Connection terminals fo...

Страница 15: ...511 MW251 20 DB1 DB2 MV26 Termination ON Repeater OFF Control Box Lobby Station Category Meaning POWER GREEN ACCESS RED Normal operation Idle Lit Off Call or monitoring in progress Lit Lit Error DIP switch 8is in the on position Off Flashing slowly Two or more DIP switches are in the on position Off Flashing slowly Role of the VL V701 14 ...

Страница 16: ...d Power Supply Unit Role Features Installation Category Meaning POWER GREEN ACCESS RED Normal operation Idle Lit Off Call or monitoring in progress Lit Lit Error DIP switch 8is in the on position Off Flashing slowly Two or more DIP switches are in the on position Off Flashing slowly 1 Power indicator POWER 2 Access indicator ACCESS 3 Connection terminals for main monitors 4 Connection terminals in...

Страница 17: ...on Controlling the destination floor of visitors by linking with the lift and lift control box Role Features Installation Residents 302 push the button And answer The Lift controller accepts only 3rd Floor Visitor comes and call Room 302 For visitors Accept 2 1 3 1 2 3 ...

Страница 18: ... box VL V701 4 3F Accept Can program the Relay operation 1 20 Accept In order for the function to work settings need to be confirmed in advance with the lift manufacturer Role of the VL V702 Supported control methods Controlling the destination of lifts Controlling the destination floor of visitors by linking with the lift and lift control box Operation Environment 10 to 50 1 1 control Relay Signa...

Страница 19: ...put for lift controller 6 Connection terminals for lifts 7 Reset button Used when restarting the lift controller 8 Function button For internal use only 9 Power switch 10 Cable release button for DC power supply cable 11 Connection terminals for DC power supply Category Meaning POWER GREEN ACCESS RED Idle Lit Off Call or monitoring in progress Lit Lit Error DIP switch 6or 7is in the on position Of...

Страница 20: ...tion terminals for DC power supply 7 Reset button Used when restarting the extension box 8 Function button For internal use only Category Meaning POWER GREEN ACCESS RED Idle Lit Off Call in progress Lit Lit Error DIP switch 4 or 6 or 7 or 8 is in the on position Lit Flashing Normal operation AC DC 24V 11 Attached Power Supply Unit Wiring run Wire diameter Max length Power supply unit Lift controll...

Страница 21: ...ng sound notification Sales Point Configuration of connected devices Role Features Installation Relay box 2 2 Relay box is included with VL SVN511 but not included with VL MVN511 1 Door Bell is connectable instead of a Door Station AC DC 24V Attached Power Supply Unit Wiring run Wire diameter Max length Power supply unit AC power source Φ1 2 mm Φ2 0 mm 17 AWG 12 AWG No requirement 2 Up to 4 Expand...

Страница 22: ... Main Monitor VL MVN511 Rea Side Role Features Installation 2 Commercially Sensor or Button Support Emergency call Commercially Sensor or Button Support Door Bell D3 D4 Door Station D1 D2 Distribution Box VL V701 21 ...

Страница 23: ... max 50 sessions Auto picture recording 2 Picture recording function Can view visitors in color even at night 3 LED Lighting Door station Sales Point Configuration of connected devices E Lock1 Lobby Station Expandable options E Lock2 Main Monitor Door Station VL MW251 is connected to AC power directly Role Features Installation 2 APARTMENT MODE HOUSE MODE ...

Страница 24: ... Picture recording function Simple UI with big talk off button 3 Easy to use big button Sales Point E Lock1 Lobby Station Main Monitor Door Bell Role Features Installation AC DC 24V Attached Power Supply Unit Configuration of connected devices 2 Wiring run Wire diameter Max length Power supply unit AC power source Φ1 2 mm Φ2 0 mm 17 AWG 12 AWG No requirement Power supply unit Main Monitor APARTMEN...

Страница 25: ... 8 shots per visitor Yes Up to 30 visitors 1 shot per visitor Door Station Yes Option Yes Option Door Bell Yes Option 3rd party Yes Option 3rd party E Lock Release Public Individual Yes Option Yes Yes Yes Yes Emergency Call Yes Others Smartphone connect Up to 4 E mail notification Up to 4 Wireless monitor Up to 4 24 2 10 Room Unit Main Monitor Lineup Free App Role Features Installation option opti...

Страница 26: ...tment mode or Housing mode Role Features Installation 2 Default is the House mode But no need to change the mode When connect to the large apartment system and run the Connection Check by Setup tool it automatically changes to Apartment mode Image of Setup tool Confirmation of mode Just as keep hold three kind of button and turn on the power 25 ...

Страница 27: ...Wiring 3 ...

Страница 28: ... AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC Room System Main Monitor Lobby Station Control Box Distribution Box Main Monitor 1 unit 1 unit 1 units 20 units Lobby Station VL V900 Entrance Control Box VL V700 Distribution VL V701 Main Monitor AC 26 ...

Страница 29: ...ystem Configuration Rear Side 3 Wiring Basic system example Power Supply Unit Lobby Station 1 Control Box 1 Distribution Box 1 Room unit up to 20 Main Monitor Door Station 1 19 Power Supply Unit Power Supply Unit 27 MVN511 MW251 20 DB1 DB2 MV26 ...

Страница 30: ... VL V900 Lobby Station Control Box Distribution Box Main Monitor 3 units 1 unit 28 units 560 units Control Box VL V700 4 branches x 7 series connections x 20 dividers 560 units 1 1 1 2 1 7 2 1 2 2 2 7 3 1 3 2 3 7 4 1 4 2 4 7 Distribution VL V701 28 ...

Страница 31: ...tion VL V900 Lobby Station Extension Box Control Box Distribution Box Main Monitor 18 units 3 units 1 unit 28 units 560 units Control Box VL V700 4 branches x 7 series connections x 20 dividers 560 units Distribution VL V701 29 4 7 3 7 2 7 1 7 Extension Box VL V703 ...

Страница 32: ...it Lobby Station 2 Lobby Station 3 Power Supply Unit Power Supply Unit 6 3 4 Large System Configuration Rear Side 3 Wiring Distribution Box 2 1 1 20 Power Supply Unit Power Supply Unit Power Supply Unit Up to 7 Distribution boxes Distribution Box 3 1 1 20 Power Supply Unit Power Supply Unit Power Supply Unit Up to 7 Distribution boxes Distribution Box 4 1 1 20 Power Supply Unit Power Supply Unit P...

Страница 33: ... Diameter of Wire 0 65 mm 22 AWG 1 20 mm 17 AWG Supply 24 V DC from Power Supply Unit Diameter of Power Cable 0 65 mm 22 AWG Max length 10 m 2 00 mm 12 AWG Max length 20 m Uses 2 wire cable Uses 2 wire cable for AC 220 240V Diameter of Power Cable 1 2 mm 17 AWG 2 0 mm 12 AWG NP NP NP NP NP NP NP NP 0 65 mm POWER SUPPLY UNIT POWER SUPPLY UNIT POWER SUPPLY UNIT AC AC AC 2wire Power Cable for DC24V 2...

Страница 34: ... mm 17 AWG approx 200 m Power supply unit Lobby station Control box Distribution box Lift controller 0 65 mm 22 AWG approx 10 m 2 mm 12 AWG approx 20 m Power supply unit AC power source 1 2 mm 17 AWG No requirement 2 mm 12 AWG Lobby station Electric lock 0 5 mm 24 AWG According to specification of connected device 1 2 mm 17 AWG Use 2 conductor solid copper wiring with a PE polyethylene insulated P...

Страница 35: ...VL V701 Lobby Station VL V900 V701 Repeater Mode 1 Distribution Box VL V701 Lobby Station VL V900 Control Box VL V700 By connecting a VL V701 repeater between the VL V700 and VL V701 07 the range can be extended by 200 m Diameter of cable Control Box VL V700 V701 Repeater Mode The Farthest Monitor The Farthest Monitor The Farthest Monitor The Farthest V701 The Farthest V701 The Farthest V701 33 To...

Страница 36: ...bby Station 10 If you use CAT6 Cable instead of 2wire cable Control Box VL V700 V701 Repeater Mode The Farthest Monitor The Farthest Monitor The Farthest V701 34 Case3 same as 1 pair x 2 110m 2 pair x 2 160m 1 pair x 2 110m 2 pair x 2 160m Power Supply of Main Monitor Distribution Box VL V701 1 pair x 2 Signal cable 1 pair x 2 Power cable Main Monitor 70m If power supply is set near the Distributi...

Страница 37: ...n switch DIP switches Repeaterswitch Termination switch DIP switch setting is Ignored when repeater switch is set to the ON position OFF ON ON DIP switches Repeater switch Termination switch 1 2 3 4 5 6 7 8 OFF OFF DIP switches Repeater switch Termination switch 1 2 3 4 5 6 7 8 OFF OFF 7 2 1 1 2 3 4 5 6 7 8 ON 35 Repeater Repeater Repeater Each branch line support up to One repeater ...

Страница 38: ...pen Only Relay 4 3F will be active 1 G 2 1F 3 2F 19 18F 20 19F Lift Control System Panasonic Lift Controller VL V702 Lift Control box VL V700 Distribution box VL V701 4 3F Accept Can program the Relay operation 1 20 Accept In order for the function to work settings need to be confirmed in advance with the lift manufacturer ...

Страница 39: ...e optional input ports to integrate with other system ex Video Intercom Access control These input ports may be installed at the top or bottom of lift system In order for the function to work settings need to be confirmed in advance with the lift manufacturer Accept Lift System Optional Input ports ...

Страница 40: ...floor per lift Up to 20 floor per lift controller 38 Port ofLift Controller 1 2 3 4 5 6 7 8 9 10 Floor 11 12 13 14 15 16 17 18 19 20 19 F 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 10 F 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 9 F 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 8 F 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 7 F 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 6 F 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 5...

Страница 41: ...er settings Up to 6 lifts Up to 6 Lifts By connecting one branch per two lift you can integrate up to 6 lifts 3 branch x 2 lift controller x 2 lift systems It can support up to 40 floor per lift 39 Lift 4 Lift 6 Lift 5 19 F 9 F 0 F 39 F 29 F 20 F 19 F 9 F 0 F 39 F 29 F 20 F Setting Real Setting Real Setting Real 19 F 9 F 0 F 39 F 29 F 20 F Real 19 F 9 F 0 F 39 F 29 F 20 F Setting Real 19 F 9 F 0 F...

Страница 42: ...tor Door Station Power Supply Unit Power Supply Unit Power Supply Unit Power Supply Unit Power Supply Unit Lift Controller 2 1 Lift Controller 2 5 Power Supply Unit Power Supply Unit Lift Controller 3 1 Lift Controller 3 5 Power Supply Unit Power Supply Unit Lift Controller 1 1 Lift Controller 1 5 Power Supply Unit Power Supply Unit 40 ...

Страница 43: ...DIP switch Floors 0 19 0 is the ground floor 99F 89F 80F 19 F 9 F 0 F 59 F 49 F 40 F 79 F 69 F 60 F 39 F 29 F 20 F 99F 89F 80F 19 F 9 F 0 F 59 F 49 F 40 F 79 F 69 F 60 F 39 F 29 F 20 F 3 4 5 DIP switch Floors 20 39 DIP switch Floors 40 59 DIP switch Floors 60 79 DIP switch Floors 80 99 Relay operation Bit8 OFF Bit8 ON Normally close Normally Open Close Open 41 ...

Страница 44: ... Lift Controller Floor bit 7 6 5 4 3 2 1 99 F 100 1 1 0 0 1 0 0 98 F 99 1 1 0 0 0 1 1 97 F 98 1 1 0 0 0 1 0 7 F 8 0 0 0 1 0 0 0 6 F 7 0 0 0 0 1 1 1 5 F 6 0 0 0 0 1 1 0 4 F 5 0 0 0 0 1 0 1 3 F 4 0 0 0 0 1 0 0 2 F 3 0 0 0 0 0 1 1 1 F 2 0 0 0 0 0 1 0 G 1 0 0 0 0 0 0 1 3 13 Lift Controller Configuration Binary control 42 Setup tool Lift 2 Lift 3 ...

Страница 45: ...Integration 4 ...

Страница 46: ...d Security Office Terminal 3 Named Parking Extension No 106 Extension No 107 Lobby Station VL V900 Entran ce Main Monitor VL MVN511 MW251 MV26 Room Control Box VL V700 Distribution Box VL V701 Control Box VL V700 Lobby Station VL V900 Entran ce Main Monitor VL MVN511 MW251 MV26 Room Control Box VL V700 Distribution Box VL V701 Control Box VL V700 Lobby Station VL V900 Entran ce Main Monitor VL MVN...

Страница 47: ...ed Parking How to call from Room to Terminal 1 Push the TALK button 2 Select Terminal name 3 Press OK 3 System 4 Integration 4 1 How to call PBX between Room and Terminal 44 Telephone cable RJ 11 How to call from Terminal to Room 1 Press 1 0 0 100 is Extension No of Control Box 2 Guidance start Please enter the room number or system command 3 Press room number 1 0 1 101 is Room Number Description ...

Страница 48: ...VL MVN511 MW251 MV26 Room Lobby Station VL V900 Entrance Terminal 1 Named Reception System Main Monitor VL MVN511 MW251 MV26 Room Main Monitor VL MVN511 MW251 MV26 Room Reception Reception mode Switching the mode Room mode Reception mode Room mode x x x x Call to Control Box Please input the room number 0 1 0 0 Reception mode Room mode ...

Страница 49: ...art Emergency call from Room No automatically start talking between room and Terminal Emergency Notice mode Guidance start and continue Emergency call from Room No Emergency call from Room No Emergency call from Room No Emergency call Send e mail Sensor Or Button Extension No 101 Extension No 102 Terminal 2 Named Gate Extension No 103 Extension No 104 Terminal 1 Named Reception Terminal 3 Named Se...

Страница 50: ... System Camera 2 Named PARKING Lobby Station VL V900 Analogue Security Camera NTSC PAL Camera 3 Named GYM Lobby Station VL V900 Analogue Security Camera NTSC PAL Guard Security Display on the monitor is the same as the live streaming video Monitor The Lobby and Security camera are both selectable 6 4 Integration 4 2 Analogue Security Camera Monitor 47 Camera Display Priority can be set Coaxial Cab...

Страница 51: ...Connecting to analogue security cameras Monitor Uses 4 Integration 1 camera can be connected to each lobby station 1 Monitor can be connected to Control Box Lobby 48 Gym Pool CCTV Security Monitor Gate CCTV ...

Страница 52: ... Monitor 102 Lobby2 Monitoring Lobby1 Main Monitor 103 General Call Main Monitor 101 Emergency Terminal Emergency call Terminal 1 Main Monitor 103 General Call Main Monitor 102 Lobby2 Monitoring 2 All calls and monitoring sessions are disconnected after the pre programmed timeout time elapses 2 2 2 System in Use System busy at the moment Stop Stop 1 Lobby2 Main Monitor 101 General Call Stop 1 Busy...

Страница 53: ...Entrance 4 4 Access Control E Lock 50 4 Integration Main Monitor VL MVN511 MW251 MV26 Room Control Box VL V700 Distribution Box VL V701 System Lobby Station VL V900 Access control Electrical Lock ...

Страница 54: ...by Station Access Control Card Reader Outside 2 N P K OUT K IN 2 N P E Lock Lobby Station K OUT K IN DOOR EXIT OR Poewe r supply 12 V DC K OUT K IN N P N P N P POWER SUPPLY UNIT VL V900 Switch Inside Switch Inside Setting by Setup Tool K IN and K OUT EXTERNAL signal OPEN Normally CLOSE Active OPEN CLOSE Normally Open Active CLOSE KEY OPEN TIME KEY OUT SIGNAL active time 0 20 s ...

Страница 55: ... UNLOCKED If integrate Access Control 1 Card Key Outside Card Reader Outside If integrate Access Control 2 Switch Inside 3 Input Pin cord Outside Lobby Station Outside Input a four digit pass code 4 Room Monitor In Room Room Monitor Push Door Key Button Switch Inside ...

Страница 56: ...02 2015 1 1 4 30 2015 1 1 4 30 T O SAVED 100_0001 LOBBY_01 RM_00102 RM_00102 2015 1 1 4 30 2015 1 1 4 30 TALK SAVED 100_0002 LOBBY_01 RM_00102 RM_00102 2015 1 1 4 30 2015 1 1 4 31 UNLOCK EV SAVED 100_0003 LOBBY_01 RM_00402 RM_00402 2015 1 1 4 31 2015 1 1 4 31 TALK SAVED 100_0004 TERMI_01 LOBBY_01 LOBBY_01 2015 1 1 4 31 2015 1 1 4 31 TALK RM_00402 TERMI_01 2015 1 1 4 31 2015 1 1 4 32 TALK LOBBY_01 ...

Страница 57: ...Setup Tool 5 ...

Страница 58: ...out 40sec until they start flashing Power LED Access LED 6 When Power LED has turned off and the Access LED is lit the update is finished Turn off the power switch It takes about 20min in total Power LED Access LED 7 Initialization Push down the Reset switch and turn on the power switch Keep pressing the switch until the Power LED is flashing 1 Back up the setting data After Updating the setting d...

Страница 59: ...the data to the system while on site The Panasonic Large Apartment System Setup Tool is also called setup tool in this document System requirements Operating system Microsoft Windows 7 Microsoft Windows 8 Additional framework Net Framework 4 0 or later 5 1 3 Installing the setup tool and USB driver 1 Download the installer Download information is available at the following web site http panasonic ...

Страница 60: ...02 No 303 No 304 No 401 No 402 No 403 No 404 Port5 Port1 Port4 Port8 Port6 Port7 Port2 Port3 Control Box VL V700 Distribution Box VL V701 Lobby Station VL V900 No 101 No 102 No 103 No 104 No 201 No 202 No 203 No 204 Port1 Port4 Port8 Port5 Port6 Port7 Port2 Port3 Distribution Box VL V701 Port1 No1 No2 ...

Страница 61: ...l Box Connect the PC vis USB and upload the date to the Control Box and Lobby from setup tool Control Box VL V700 Lobby Station VL V900 3 Wiring all monitors based on the drawing and upload set the date from tool 4 Calling from Lobby to each room and check the audio and video quality No 301 Drawing Programing date should be back up by the Installer or Dealer ...

Страница 62: ... Port Port Port Port Port Port Port Port Control Box VL V700 Distribution Box VL V701 Lobby Station VL V900 No 101 No 102 No 103 No 104 No 201 No 202 No 203 No 204 Port1 Port8 Port Port Port Port Port Port Port Port Distribution Box VL V701 Port No No Situation2 If you don t know where the each cable connect to ...

Страница 63: ...n t know where the each cable connect to Push 3 buttons and Power on Save Save the programing date in the internal memory No 301 Port Port Control Box VL V700 Distribution Box VL V701 Set Save in the internal memory and send the saved date to the Control Box See 5 8 Lobby station programing See 5 10 Main Monitor programing 4 Connect the PC and Control Box vis USB and download the Programing date P...

Страница 64: ...the existing system 2 On the PC setup tool select the back up date folder and then select the existing files No 301 Control Box VL V700 Distribution Box VL V701 3 Connect the PC and Control Box vis USB and send set the General date to the new Monitor No 301 Port Port Control Box VL V700 Distribution Box VL V701 No 301 Port Port Control Box VL V700 Distribution Box VL V701 301 60 ...

Страница 65: ... the current data from the system s devices 3 Load and edit the data Allows you to load the data saved in the configuration files into the setup tool for uploading or editing 4 Upload the data to device Allows you to upload the data saved in the configuration files to the system s devices 5 Time and data settings Allows you to set the control box s time and date settings used for time stamps saved...

Страница 66: ...etup Tool 5 Step 1 Select folder To create NEW configuration file Step 2 Click These files are generated to the selected folder by Step1 Step 3 Step 4 Click The paths of each configuration file are displayed in the Load and edit the data section 62 ...

Страница 67: ...to the configuration file 2 Change the values in the appropriate columns 4 Click Tips Editing configuration files directly Use a third party text editor or spreadsheet program to open the configuration file Files that are ready to be uploaded are indicated by OK displayed in the right side of the Load and edit the data section If you enter an incorrect value an error may displayed when you click L...

Страница 68: ... devices Setup Tool 5 To download from devices Step 1 Select folder Step 2 Note Before download from devices connect the computer to the control box with a USB cable Turn on the checkboxes for the desired devices listed under Download the data from Step 3 Click 64 ...

Страница 69: ...onding control box port distribution box number and distribution box port 1 99999 Floor No Determines the floor number setting of the corresponding room number 0 99 0 is the ground floor 0 Lift access permission Determines which lifts can be used by visitors to each lobby station 0 No lifts can be used Lobbay 1 Lobbay 2 Lobbay 3 Lift 1 Lift 2 Lift 3 65 ...

Страница 70: ...e priority 1 900 s or 0 to disable 300 300 SEC Visitor Call Mode Determines if visitors can call rooms directly room mode or if their calls are directed to a reception terminal reception mode 0 ROOM MODE 1 RECEPTION MODE 0 ROOM MODE Terminal 1 4 Extension Number Tells the system the extension number for terminal 1 4 24 digits max Terminal 1 4 Name Code Determines the name for terminal 1 4 1 TERMIN...

Страница 71: ...3 Room settings Setup Tool 5 Parameter Description Default Room No Determines the room number 0 99999 Resident Name Determines the resident name for the corresponding room number 20 characters max uppercase letters only 67 ...

Страница 72: ...ed 0 CLOSE 1 OPEN 0 CLOSE Camera Connection Tells the system whether a camera is connected or not 0 NO 1 YES 0 NO Camera Name Determines the camera name 1 CAMERA 2 RECEPTION 3 GATE 4 CONTROL ROOM 5 RESTAURANT 6 HALL 7 POOL 8 SECURITY OFFICE 9 ENTRANCE 10 GYM 11 GUEST ROOM 12 KID S ROOM 13 PARKING 14 TERRACE 15 LIFT LOBBY 1 CAMERA Camera Display Priority Determines which camera image is displayed w...

Страница 73: ...obby station exits programming mode and the standby screen is displayed Entering numbers and characters You can use the keypad to enter numbers and characters Press a key repeatedly to scroll through the characters assigned to that key Follow the hints displayed on the bottom of the display To erase the rightmost number or character press To advance the cursor press To cancel press To confirm or s...

Страница 74: ...PARKING 06 HALL 14 TERRACE 07 POOL 15 LIFT LOBBY 08 SECURITY OFFICE Feature number Description 0 Emergency terminal 1 Terminal 1 2 Terminal 2 3 Terminal 3 4 Terminal 4 5 Enter a feature number to specify the terminal s operation mode Feature number Description 0 0 default For the emergency terminal Selects EMERGENCY TALK mode During an emergency call the main monitor can talk to the emergency term...

Страница 75: ...ts settings While performing the next steps you can cancel without saving your settings by pressing OFF 5 Enter the room number a Use the navigator key to select the desired number b Use the navigator key to accept the entered number and advance the cursor c Press OK when finished 6 Enter the floor number a Use the navigator key to select the desired number b Press OK when finished 7 Set lift perm...

Страница 76: ...ge for visitors to each lobby b Press to select the next lobby station c Press OK when finished 8 Confirm the displayed settings Press EDIT to go back and enter the desired settings again 9 Press SET to check for a duplicate room number If a duplicate room number is found press YES or NO to select whether you want to overwrite the existing room number settings If no duplicate is found the settings...

Страница 77: ...vice Setup Tool 5 You can restart the control box distribution box or lift controller by pressing its reset button Reset button Reset button Reset button Reset button VL V900 VL V700 VL V701 VL V702 73 VL V703 Reset button ...

Страница 78: ...Operation 6 ...

Страница 79: ...y repeatedly to scroll through the letters assigned to that key Note the hints displayed at the bottom of the screen 3 Press or to search for the desired name 4 Press to call Searching through all names 1 Press 2 Press or to search for the desired name 3 Press to call 6 1 2 Calling a receptionist 1 Press 2 Press or to search for the receptionist 3 Press to call 6 1 3 Opening the door by entering a...

Страница 80: ...en the entrance door based on the conversation he she had with the visitor When the visitor call mode setting is set to reception mode calls from lobby visitors are directed to a reception terminal even if the visitor called a specific resident or room number Visitors do not speak directly with residents The reception terminal user can open the entrance door based on the conversation he she had wi...

Страница 81: ...Replace 7 ...

Страница 82: ...stribution Box VL V701 Control Box VL V700 RISER POWER POWER POWER POWER POWER DC Power IP LAN L2 Switch Hub AC L2 Switch Hub L2 Switch Hub Room Monitor Lobby Station Control Box Distribution Box New Cable Cat 6 1 2mm 0 65mm Distribution Box DC Power Supply Room Monitor Existing Cable Cat 5e Power Cable Lobby Station Cat5e Cable Cat6 Cable 1 2mm 0 65mm 7 RISER ...

Страница 83: ...ble Cat 6 Control Box Distribution Box New Cable Cat 6 Distribution Box Room Monitor Exiting Cable PVC cable less than 30m Replace from Intercom system PVC mesh cable Distribution Box VL V701 Control Box VL V700 Cat6 Cable Replace 77 ...

Страница 84: ...s than 30m from Raiser Raiser Replace exiting PVC cable to CAT6 cable from Control Box to each distribution box Exiting Fermax Lobby Station have camera But room monitor do not support Video Back board will be also replaced soon for new Lobby Station AC 220V using 2 wire Existing cable is 7 wire Replace 78 ...

Страница 85: ...rol Box and Distribution Box Cat5E Cable to Each Room Monitor Room Raiser Power Cable Remove the Existing Room Monitor Connect the Cat5e and Power Cable Existing Power Supply Power Supply PS240 Put the Distribution Box in the PVC Box prepared by Sier 7 1 Replace from Cat 5e Cable IP System 7 ...

Страница 86: ... Distribution Box VL V701 Control Box VL V700 Cat6 Cable 1 2mm 0 65mm RISER IP LAN PoE SW Hub L2 Switch Hub Room Monitor Lobby Station PoE SW Hub Cat5e Cable Lobby Station Control Box Existing Cable Cat3 New Cable Control Box Distribution Box New Cable Cat 6 1 2mm 0 65mm Distribution Box DC Power Supply Room Monitor Existing Cable Cat 5e 7 ...

Страница 87: ...4wire Distribution Box VL V701 Distribution Box VL V701 Control Box VL V700 RISER Lobby Station Control Box Existing Cable Cat3 New Cable Control Box Distribution Box New Cable Cat 6 1 2mm 0 65mm Distribution Box DC Power Supply Room Monitor Existing Cable Cat 5e New Cable Lobby Station Cat6 Cable 1 2mm 0 65mm 7 RISER ...

Страница 88: ...Estimate 8 ...

Страница 89: ...How to make an estimate of the system 8 Estimate 82 Huge Multi Building Villa complex High rise ...

Страница 90: ...boxes are needed 11 20 Rooms Floor Install one distribution box per each floor 301 302 303 316 317 320 201 202 203 216 217 220 3F 2F 1F 101 102 103 116 117 120 Distribution box Distribution box Distribution box 8 Estimate 83 ...

Страница 91: ... 10 Rooms Floor Install one distribution box per two floors 301 302 303 310 201 202 203 210 101 102 103 110 3F 2F 1F Distribution box Distribution box How many distribution boxes are needed 8 Estimate 84 ...

Страница 92: ...Case study 8 Rooms Floor Indonesian project 1 2 3 4 5 6 7 8 Distribution box Distribution box Control box How many distribution boxes are needed 1F 2F 4F 3F 5F 6F 8 Estimate 85 ...

Страница 93: ...How many distribution boxes are needed 6 Rooms Floor Install one distribution box per three floors 301 302 306 201 202 206 101 102 106 3F 2F 1F Distribution box 8 Estimate 86 ...

Страница 94: ...Case study 6 Rooms Floor Myanmar Project 1 2 3 4 5 6 Distribution box Control box 1F 2F 3F 4F 8 Estimate How many distribution boxes are needed 87 ...

Страница 95: ...Main Monitor Power Supply 8 Estimate AC DC 24V Attached Power Supply Unit AC DC 24V VL MVN511 VL MV26 AC power directly VL MW251 AC 88 ...

Страница 96: ... 2F AC 220V 8 Estimate Where is Power supply unit installed AC 220V Supplied AC Power from each room Power supply unit of MV511 MV26 is installed at room MW251 is directly connected to AC 220V of room 89 ...

Страница 97: ...re is Power supply installed 301 302 306 201 202 206 3F 2F AC 220V AC 220V 8 Estimate Install Power supply unis at Riser and DC output is wired to each monitor DC 24V DC 24V DC 24V DC 24V DC 24V DC 24V 90 ...

Страница 98: ...02 306 201 202 206 3F 2F AC 220V AC 220V 8 Estimate Cat5e Cat6 Cable Cat3 0 65mm 4wire Install Power supply unis at Riser and DC output is wired with signal cable Up to 70m Where is Power supply installed 91 ...

Страница 99: ...units 20units 20units Tower1 20units 20units 20units Tower2 20units 20units 20units Tower3 20units 20units 20units Tower4 Distribution box Repeater Repeater 100m φ0 65 200m φ1 2 100m φ0 65 200m φ1 2 Distribution box Distribution box 8 Estimate Control box 92 ...

Страница 100: ...How to support multi building Case study 3 tower 1 entrance Malaysia project Distribution box Repeater Distribution box Repeater Distribution box Control box 8 Estimate 93 ...

Страница 101: ...How to support multi building 8 tower 2 entrance Lobby for Tower1 4 Lobby for Tower5 8 Lobby for Tower1 4 Lobby for Tower5 8 8 Estimate 94 ...

Страница 102: ...How to support more than 4 Lobby Station project 8 Estimate We will Launch Extension box VL V703 at the end of July 95 ...

Страница 103: ...igh rise building with 8 Lobby Stations Repeater Extension Box 20F 15F 14F P P P 13F 7F 6F 5F 4F 1F GF Control box Distribution box 8 Estimate How to support more than 4 Lobby Station project Repeater 96 ...

Страница 104: ...How to support the villa complex 8 Estimate 97 ...

Страница 105: ...ontrol box Distribution box Repeater Distribution box Distribution box Distribution box Repeater Distribution box Distribution box Outdoor cabinet 8 Estimate Piping under the ground Case study 108 house gated community Malaysia project ...

Страница 106: ...ions with CCTV or terminals Qty of Reception security room How many terminals which is integrated with PBX Qty of Lift How many Lift controllers Public space for monitoring How many Analog CCTV which is connected to Lobby Project drawing dimension How long Need repeater What kind of cable Other security System Ex access control EM Lock at the entrance Sensor Punic button EM Lock PBX Telephone at r...

Страница 107: ...e Signal cable Power cable length of each cable Existing type of cable Check the possibility of replace by using existing cable Signal cable Power cable Type of cable CAT5e CAT3 telephone cable PVC cable Thin of cupper Material of isolation and cover If difficult to know get the 100m sample cable Existing integrated system Make sure of the possibility of not only the video intercom but also all in...

Страница 108: ...FAQ 9 ...

Страница 109: ...Appendix 10 ...

Страница 110: ...d Hands free Viewing angle Horizontally Approx 170 Vertically Approx 115 Installation method Flush mount flush mounting box supplied Image sensor 1 0 M pixel CMOS Minimum illuminance 1 lx within approx 50cm from the camera lens Lighting method White coloured LED lights IP rating IK rating IP55 1 Compliant with IK07 1 External material Stainless steel partially ABS and PC Expanded interface Support...

Страница 111: ...Installation method Wall mount or attach to DIN rail External material ABS flame retardant ABS resin Log Save the text logs and visitors images in the SD card sold separately Text logs More than 90 000 items Images Up to 90 000 images Supported functions USB connection provide PC application English date and time setting HH MM DD MM YYYY set the room number with the monitor estimate the status of ...

Страница 112: ... DIN rail External material ABS flame retardant ABS resin Log Save the text logs and visitors images in the SD card sold separately Text logs More than 90 000 items Images Up to 90 000 images Supported functions USB connection provide PC application English date and time setting HH MM DD MM YYYY set the room number with the monitor estimate the status of the equipment in the system operation setti...

Страница 113: ...ing protruding sections 108 5 x 210 x 52 5 mm Weight 400 g Operating environment Ambient temperature Approx 10 C to 50 C Relative humidity non condensing up to 90 indoor use only Installation method Wall mount or attach to DIN rail External material ABS flame retardant ABS resin Supported functions Dip switch Mode change Distribution mode Repeater mode Termination setting Normal Terminal ID settin...

Страница 114: ... Approx 0 4 W During operation Approx 4 4 W Dimensions H x W x D Excluding protruding sections 210 x 108 5 x 52 5 mm Weight 400 g Operating environment Ambient temperature Approx 0 C to 50 C Relative humidity non condensing up to 90 Indoor installation only Installation method Wall mount or attach to DIN rail External material ABS flame retardant ABS resin ...

Страница 115: ...dby Approx 1 5W During operation 1 3W Dimensions H x W x D Excluding protruding sections 210 x 108 5 x 52 5 mm Weight 400 g Operating environment Ambient temperature Approx 10 C to 50 C Relative humidity non condensing up to 90 Indoor installation only Installation method Wall mount or attach to DIN rail External material ABS flame retardant ABS resin ...

Страница 116: ...Operating environment Ambient temperature Approx 0 C to 40 C Relative humidity non condensing up to 90 Ambient temperature Approx 0 C to 40 C Relative humidity non condensing up to 90 Ambient temperature Approx 0 C to 40 C Relative humidity non condensing up to 90 Electric lock release support Up to 2 1 for individual x1 for public x1 Up to 2 for individual x1 for public x1 Up to 1 for public Pict...

Страница 117: ...ntrol Box VL V701 Distribution Box VL V702 Lift Controller 1 Wire release button 2 Connection terminal 3 Wires to from other devices 4 Cable release button for DC power supply cable 5 DC cable from power supply unit 1 2 3 4 5 6 9 Appendix ...

Страница 118: ... cable covers 2 Connect the AC DC cable to the AC IN terminal DC OUT terminal on the top and bottom of the power supply unit and then securely fasten the screws 3 AC cable binder hole DC cable Screws 3 1 1 Cable binders 1 Make sure that there are no bare wires exposed outside the product Cable covers 2 Screws 1 Use the cable binders to secure the AC DC cables double coated area to the power supply...

Страница 119: ...evice must be installed inside an electrical panel or cabinet A readily accessible disconnect device shall be incorporated external to the equipment External disconnect device must be certified and have a creepage and clearance distance of 3 mm or more Precautions for wiring Make sure you turn off the power at the breaker before performing any wiring work Always connect AC or DC cables to the appr...

Страница 120: ...oom Unit up to 560 01 01 07 01 07 Distribution Box 06 04 07 05 Repeater Mode Repeater Mode 01 05 01 05 01 05 Lobby Station up to 3 Distribution Box up to 28 up to 5 per lift TV Monitor 1 NTSC PC programming SD Card Log Emergency SLT 1 PBX SLTs up to 4 Security Camera E Lock Control Box 1 Repeater Mode up to 1 per 1branches You can extend the distance by using the repeater mode Extension Box up to ...

Страница 121: ......

Страница 122: ...either registered trademarks or trademarks of Microsoft Corporation in the United States and or other countries All other trademarks identified herein are the property of their respective owners The actual product may vary slightly from photograph All pictures of the LCD display are simulated Weights and dimensions are approximate Design and Specifications are subject to change without notice Thes...