TH-L32E3A
3
1 Safety Precautions
1.1.
General Guidelines
1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
2. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
3. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
4. When conducting repairs and servicing, do not attempt to modify the equipment, its parts or its materials.
5. When wiring units (with cables, flexible cables or lead wires) are supplied as repair parts and only one wire or some of the
wires have been broken or disconnected, do not attempt to repair or re-wire the units. Replace the entire wiring unit instead.
6. When conducting repairs and servicing, do not twist the Faston connectors but plug them straight in or unplug them straight
out.
1.1.1.
Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the
two prongs on the plug.
2. Measure the resistance value, with an ohmmeter,
between the jumpered AC plug and each exposed
metallic cabinet part on the equipment such as
screwheads, connectors, control shafts, etc. When the
exposed metallic part has a return path to the chassis, the
reading should be 100 Mohm and over.
When the exposed metal does not have a return path to
the chassis, the reading must be
.
1.1.2.
Leakage Current Hot Check (See
Figure 1.)
1. Plug the AC cord directly into the AC outlet. Do not use
an isolation transformer for this check.
2. Connect a 1.5kohm, 10 watts resistor, in parallel with a
0.15
μ
F capacitors, between each exposed metallic part
on the set and a good earth ground such as a water pipe,
as shown in Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more
sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the
voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of
the above measurements.
6. The potential at any point should not exceed 0.75 volts
RMS. A leakage current tester (Simpson Model 229 or
equivalent) may be used to make the hot checks, leakage
current must not exceed 1/2 milliamp. In case a
measurement is outside of the limits specified, there is a
possibility of a shock hazard, and the equipment should
be repaired and rechecked before it is returned to the
customer.
Figure 1
Содержание VIERA TH-L32E3A
Страница 25: ...TH L32E3A 25 11 Schematic Diagram 11 1 Schematic Diagram Notes ...
Страница 26: ...TH L32E3A 26 11 2 A Board 11 2 1 A Board Sheet 002 1 2 1A 2A 3A ...
Страница 27: ...TH L32E3A 27 11 2 2 A Board Sheet 002 2 2 1A 2A 3A ...
Страница 28: ...TH L32E3A 28 11 2 3 A Board Sheet 003 1 5 1A 2A ...
Страница 29: ...TH L32E3A 29 11 2 4 A Board Sheet 003 2 5 1B 2B 1A 2A ...
Страница 30: ...TH L32E3A 30 11 2 5 A Board Sheet 003 3 5 1C 2C 1B 2B ...
Страница 31: ...TH L32E3A 31 11 2 6 A Board Sheet 003 4 5 1D 2D 1C 2C ...
Страница 32: ...TH L32E3A 32 11 2 7 A Board Sheet 003 5 5 1D 2D ...
Страница 33: ...TH L32E3A 33 11 2 8 A Board Sheet 004 1 2 1A 2A ...
Страница 34: ...TH L32E3A 34 11 2 9 A Board Sheet 004 2 2 1A 2A ...
Страница 35: ...TH L32E3A 35 11 2 10 A Board Sheet 005 1 2 1A 2A ...
Страница 36: ...TH L32E3A 36 11 2 11 A Board Sheet 005 2 2 1A 2A ...
Страница 37: ...TH L32E3A 37 11 2 12 A Board Sheet 008 1 1 ...
Страница 38: ...TH L32E3A 38 11 2 13 A Board Sheet 009 1 3 1A 2A 3A 4A ...
Страница 39: ...TH L32E3A 39 11 2 14 A Board Sheet 009 2 3 1B 2B 1A 2A 3A 4A ...
Страница 40: ...TH L32E3A 40 11 2 15 A Board Sheet 009 3 3 1B 2B ...
Страница 41: ...TH L32E3A 41 11 2 16 A Board Sheet 010 1 1 ...
Страница 42: ...TH L32E3A 42 11 2 17 A Board Sheet 100 1 2 1A 2A 3A ...
Страница 43: ...TH L32E3A 43 11 2 18 A Board Sheet 100 2 2 1A 2A 3A ...
Страница 44: ...TH L32E3A 44 11 2 19 A Board Sheet 101 1 3 1A 2A ...
Страница 45: ...TH L32E3A 45 11 2 20 A Board Sheet 101 2 3 1B 2B 1A 2A ...
Страница 46: ...TH L32E3A 46 11 2 21 A Board Sheet 101 3 3 1B 2B ...
Страница 47: ...TH L32E3A 47 11 2 22 A Board Sheet 300 1 1 ...
Страница 48: ...TH L32E3A 48 11 2 23 A Board Sheet 301 1 3 1A 2A ...
Страница 49: ...TH L32E3A 49 11 2 24 A Board Sheet 301 2 3 1B 2B 3B 1A 2A ...
Страница 50: ...TH L32E3A 50 11 2 25 A Board Sheet 301 3 3 1B 2B 3B ...
Страница 51: ...TH L32E3A 51 11 2 26 A Board Sheet 302 1 2 1A 2A 3A 4A ...
Страница 52: ...TH L32E3A 52 11 2 27 A Board Sheet 302 2 2 1A 2A 3A 4A ...
Страница 53: ...TH L32E3A 53 11 2 28 A Board Sheet 700 1 2 1A 2A 3A 4A ...
Страница 54: ...TH L32E3A 54 11 2 29 A Board Sheet 700 2 2 1A 2A 3A 4A ...
Страница 55: ...TH L32E3A 55 11 2 30 A Board Sheet 701 1 2 1A 2A 3A ...
Страница 56: ...TH L32E3A 56 11 2 31 A Board Sheet 701 2 2 1A 2A 3A ...
Страница 57: ...TH L32E3A 57 11 2 32 A Board Sheet 702 1 2 1A 2A 3A ...
Страница 58: ...TH L32E3A 58 11 2 33 A Board Sheet 702 2 2 1A 2A 3A ...
Страница 59: ...TH L32E3A 59 11 2 34 A Board Sheet 703 1 1 ...
Страница 60: ...TH L32E3A 60 11 2 35 A Board Sheet 704 1 1 ...
Страница 61: ...TH L32E3A 61 11 2 36 A Board Sheet 708 1 1 ...
Страница 62: ...TH L32E3A 62 11 3 KA Board ...
Страница 63: ...TH L32E3A 63 11 4 LD Board 11 4 1 LD Board 1 2 1A 2A 3A ...
Страница 64: ...TH L32E3A 64 11 4 2 LD Board 2 2 1A 2A 3A ...
Страница 65: ...TH L32E3A 65 11 5 P Board 11 5 1 P Board 1 3 1A 2A 3A 4A ...
Страница 66: ...TH L32E3A 66 11 5 2 P Board 2 3 1B 2B 3B 1A 2A 3A 4A ...
Страница 67: ...TH L32E3A 67 11 5 3 P Board 3 3 1B 2B 3B ...
Страница 68: ...TH L32E3A 68 11 6 TC Board 11 6 1 TC Board 1 2 1A 2A 3A 4A ...
Страница 69: ...TH L32E3A 69 11 6 2 TC Board 2 2 1A 2A 3A 4A ...
Страница 88: ...Model No TH L32E3A Parts Location ...
Страница 89: ...Model No TH L32E3A Packing Exploded View ...