background image

MULTI PIP
DISPLAY MODE

PIP

 OFF 

1

INSERT LEVEL

TRANSPARENCY

INSERT

0 %

TRANSPARENCY LEVEL

OFF

MULTI PIP SETUP

2/2 

SET UP

MULTI DISPLAY SETUP

SET UP TIMER

MULTI PIP SETUP

PORTRAIT SETUP

36

MULTI PIP SETUP

Set the two-screen display function that is activated when 

 is pressed.

Press to select the MULTI PIP SETUP.

Press to display the “MULTI PIP SETUP” menu.

Press to display the SET UP menu.

1
2

3

Press to select the menu to adjust.
Press to adjust the menu.

Sub Screen Insertion (During BLEND PIP)

1

   Select “ON” in “INSERT”.

2

   Set the “INSERT LEVEL”. (1 to 10 %)

       Set the brightness level threshold for discriminating between the transparent areas and non-transparent areas on the sub screen.
      Setting example   Image to insert (sub screen)     

INSERT LEVEL

                                 

Background image 

(main screen)

Two-picture insertion

Only the areas on the overlay 
image that are brighter than 
the “INSERT LEVEL” are 
displayed on the background 
image.

10 %

1 %

Note: 

“TRANSPARENCY” cannot be set when “INSERT” is “ON”.

Transparent Display of the Sub Screen (During BLEND PIP)

1

   Select “ON” in “TRANSPARENCY”.

2

   Set the transparency level for the sub screen in “TRANSPARENCY LEVEL”. (0 to 100 %)

   Setting example  Transparent image (sub screen)
                                 

0 %: No transparency

100 %: Fully transparent

Note: 

“INSERT” cannot be set when “TRANSPARENCY” is “ON”.

MULTI PIP

Set the two-screen function.

   

PIP

ADVANCED PIP

BLEND PIP

DISPLAY MODE

The display mode can be changed separately for each function that was set in “MULTI PIP SETUP”.
      For “PIP”:  

— (One screen)

P AND P

P OUT P

P IN P

   For “ADVANCED PIP”:  

— (One screen)

1 to 8

   For “BLEND PIP”: 

— (One screen)

FULL

P IN P

Note: 

The display mode changes in the same way when 

 is pressed.

Содержание Viera TH-58PF11

Страница 1: ... TH 50PF11UK TH 58PF11UK TH 65PF11UK Model No Número de modelo TQB2AA0804 Antes de conectar utilizar o ajustar este producto lea completamente este manual de instrucciones y guárdelo para consultarlo en el futuro en caso de ser necesario Español La ilustración mostrada es una imagen Operating Instructions Manual de instrucciones High Definition Plasma Display Alta definición Pantalla de plasma ...

Страница 2: ...let contact an electrician Do not defeat the purpose of the grounding plug This video monitor is designed to display television content from a separate TV tuner Full power analog TV broadcasting in the United States will end as required by law on February 17 2009 after which full power TV broadcasts will be digital only If this device is used after that date to record or display programming from a...

Страница 3: ...ent of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when movi...

Страница 4: ... Menu Displays 23 Adjusting POS SIZE 24 PICTURE Adjustments 26 ADVANCED SETTINGS 27 SOUND Adjustment 28 SDI SOUND OUTPUT 28 PRESENT TIME SETUP SET UP TIMER 29 PRESENT TIME SETUP 29 SET UP TIMER 29 SCREENSAVER For preventing image retention 30 Setup of SCREENSAVER Time 30 Reduces screen image retention 31 SIDE BAR ADJUST 31 Reduces power consumption 32 Customizing the Input labels 33 DISPLAY ORIENT...

Страница 5: ...ce that may cause undesired operation FCC CAUTION To assure continued compliance follow the attached installation instructions and use only shielded interface cables when connecting to computer or peripheral devices Any changes or modifications not expressly approved by Panasonic Corp of North America could void the user s authority to operate this device FCC Declaration of Conformity Model No TH ...

Страница 6: ...W K for TH 42PF11UK TY SP50P8W K for TH 50PF11UK TY SP58P10WK for TH 58PF11UK TY SP65P11WK for TH 65PF11UK Pedestal TY ST07 K for TH 42PF11UK TY ST08 K for TH 42PF11UK TH 50PF11UK TY ST58 K for TH 58PF11UK TY ST65P11 K for TH 65PF11UK Mobile stand TY ST42PF3 for TH 42PF11UK TY ST58PF10 for TH 42PF11UK TH 50PF11UK TH 58PF11UK Wall hanging bracket vertical TY WK42PV7 for TH 42PF11UK TH 50PF11UK TH 5...

Страница 7: ...nward may cause damage to the internal circuitry If using the pedestal optional accessory leave a space of 3 15 16 10 cm or more at the top left and right and 2 3 4 7 cm or more at the rear and also keep the space between the bottom of the display and the floor surface If using some other setting up method follow the manual of it If there is no specific indication of installation dimension in the ...

Страница 8: ...not attempt to charge short circuit disassemble heat or burn used batteries 5 Battery replacement is necessary when the remote control acts sporadically or stops operating the Plasma Display 6 Do not burn or breakup batteries Batteries must not be exposed to excessive heat such as sunshine fire or the like 3 Replace the cover Accessories Supplied Check that you have the Accessories and items shown...

Страница 9: ...l for details on speaker installation Speakers Optional accessories Pass the attached cable fixing band through the clip as shown in the figure To secure cables connected to Terminals wrap the cable fixing band around them then pass the pointed end through the locking block as shown in the figure While ensuring there is sufficient slack in cables to minimize stress especially in the power cord fir...

Страница 10: ...s not DDC2B compatible you will need to make setting changes to the computer at the time of connection Some PC models cannot be connected to the set There is no need to use an adapter for computers with DOS V compatible Mini D sub 15P terminal The computer shown in the illustration is for example purposes only Additional equipment and cables shown are not supplied with this set Do not set the hori...

Страница 11: ... C1 C2 C3 P1 P2 P3 P4 P5 ETX Notes If multiple commands are transmitted be sure to wait for the response for the first command to come from this unit before sending the next command If an incorrect command is sent by mistake this unit will send an ER401 command back to the computer SL1A SL1B SL2AandSL2BofCommandIMSareavailable only when a dual input terminal board is attached Pin layout for SERIAL...

Страница 12: ...B Camcorder or DVD Example of input signal source Digital TV SET TOP BOX DTV STB HDMI connection This unit has terminal boards equivalent to Dual HDMI Terminal Board TY FB10HMD and BNC Component Video Terminal Board TY 42TM6A as standard equipment HDMI cables DVD player DVD player Pin assignments and signal names 19 3 1 4 2 18 Note Additional equipment and HDMI cables shown are not supplied with t...

Страница 13: ...socket outlet first Press the Power switch on the Plasma Display to turn the set on Power On Power Indicator Green Press the button on the remote control to turn the Plasma Display off Power Indicator Red standby Press the button on the remote control to turn the Plasma Display on Power Indicator Green Turn the power to the Plasma Display off by pressing the switch on the unit when the Plasma Disp...

Страница 14: ...t Following screen will be displayed when the unit is turned on for the first time Select the items with the remote control Unit buttons are invalid OSD LANGUAGE PRESENT TIME SETUP DISPLAY ORIENTATION Notes Once the items are set the screens won t be displayed when switching on the unit next time After the setting the items can be changed in the following menus OSD LANGUAGE see page 15 PRESENT TIM...

Страница 15: ... be selected if the terminal board is not installed into the SLOT Select to match the signals from the source connected to the component RGB input terminals see page 39 In two screen display the same input mode cannot be selected for the main picture and sub picture Image retention image lag may occur on the plasma display panel when a still picture is kept on thepanelforanextendedperiod Thefuncti...

Страница 16: ... Indicator not illuminated The unit will still consume some power as long as the power cord is still inserted into the wall outlet Standby Red Power ON Green DPMS Orange With PC input signal and during operation of PC s screensaver Volume Adjustment Volume Up Down When the menu screen is displayed press to move the cursor up press to move the cursor down see page 23 Enter Aspect button see page 18...

Страница 17: ...ton to display the current system status 1 Input label 2 Aspect mode see page 18 3 Off timer The off timer indicator is displayed only when the off timer has been set 4 Clock display see page 46 R button see page 23 Press the R button to return to previous menu screen POSITION buttons ACTION button Press to make selections POS SIZE button see page 24 PICTURE button see page 26 INPUT button Press t...

Страница 18: ...justment For letter box image Image is expanded 4 3 Changes in accordance with the Panasonic AUTO mode setting see page 41 For a 4 3 image The aspect mode changes each time the ENTER button is pressed During MULTI PIP Operations Picture and Picture Picture in Picture 4 3 FULL Others Aspect switching is not possible from the unit Note When selecting an input slot that attaches BNC Dual Video Termin...

Страница 19: ...IP SETUP is changed see page 36 During PIP During Advanced PIP One screen Advanced PIP Main screen Sub screen 1 8 2 7 3 6 4 5 One screen Two screens P AND P Sub screen input mode Main screen input mode Two screens P OUT P Two screens P IN P Main screen Sub screen INPUT1 PC PC INPUT1 INPUT1 PC Note and button operations are not available during advanced PIP For SD signal input 525 480 60i 60p 625 5...

Страница 20: ...nd the insertion function Set these functions with TRANSPARENCY or INSERT in MULTI PIP SETUP see page 36 Transparent Function Data such as text are displayed transparently on the background image Insertion Function The sub screen image is divided into transparent and non transparent areas and only the non transparent areas are inserted and displayed on the background image Note Be aware that if yo...

Страница 21: ... permanent image retention to remain on the screen If INPUT lock in Options menu is set to other than Off MULTI PIP function isn t available Sound output is from the picture which is selected in AUDIO OUT PIP see page 28 In two screen display the same input mode cannot be selected for the main picture and sub picture The main picture and sub picture are processed by different circuits resulting in...

Страница 22: ...e out Picture Picture and Picture operation see page 20 When MULTI DISPLAY SETUP is ON see page 34 When PORTRAIT SETUP is ON see page 37 When SCREENSAVER except for NEGATIVE IMAGE is running see page 30 While Digital Zoom is in operation Adjusting POS SIZE cannot be used Select the magnification required for the enlarged display Each time this is pressed the magnification factor changes This is sh...

Страница 23: ...ACK EXTENSION AGC GAMMA INPUT LEVEL ADVANCED SETTINGS NORMAL NORMALIZE OFF 2 2 SOUND OUT LEFT CHANNEL RIGHT CHANNEL CHANNEL 1 CHANNEL 1 OFF LEVEL METER OFF SDI SOUND OUTPUT 0 0 0 1 2 SOUND NORMAL NORMALIZE STANDARD OFF TREBLE AUDIO MENU BALANCE BASS 0 MID SURROUND MAIN AUDIO OUT PIP MULTI PIP DISPLAY MODE PIP OFF 1 INSERT LEVEL TRANSPARENCY INSERT 0 TRANSPARENCY LEVEL OFF MULTI PIP SETUP 23 On Scr...

Страница 24: ...ot be controlled by the POS SIZE function If adjusting the PICTURE V POS V SIZE in Panasonic AUTO with FULL mode the adjustment is not memorized When exiting the mode the screen will return to a former adjustment AUTO SETUP Automatically adjust H POS V POS CLOCK PHASE DOT CLOCK and set H SIZE V SIZE the standard value when RGB signal is input Notes If the dot clock frequency is 162 MHz or higher D...

Страница 25: ...t Notes Select ON when you would like to replay 1920 1080 input signal Applicable input signal 1125 1080 50i 60i 24sF 24p 25p 30p 50p 60p 1250 1080 50i Select OFF when flickering is shown around the image H SIZE V SIZE and DOT CLOCK cannot be adjusted when ON is selected OFF ON 1 1 PIXEL MODE 2k1k For 2k1k signals When the input signal is a 2k1k signal 2048 1080 24p 2048 1080 24sF the display size...

Страница 26: ... menu PEAK LIMIT see page 31 SET UP menu POWER SAVE see page 32 MULTI DISPLAY SETUP menu AI SYNCHRONIZATION see page 35 PORTRAIT SETUP menu AI SYNCHRONIZATION see page 38 If you would like to change the picture and color of the selected PICTURE menu to something else adjust using the items in the PICTURE menu see next page Press to select ON PICTURE Adjustments 1 ADVANCED SETTINGS ON Enables fine ...

Страница 27: ...ils BLACK EXTENSION Less More Adjusts the dark shades of the image in gradation INPUT LEVEL Less More Adjustment of parts which are extremely bright and hard to see This cannot be adjusted when the input signal is Digital GAMMA Down Up S CURVE 2 0 2 2 2 5 2 6 When 2k1k signals are received with the Dual Link HD SDI Terminal Board TY FB11DHD GAMMA 2 6 can also be selected AGC OFF ON Increases the b...

Страница 28: ...in picture sound SUB Selects PIP frame sound A B INPUT1 PC A B INPUT1 PC Musical note is displayed on right side of the audio output screen label Item Details LEFT CHANNEL CHANNEL 1 to CHANNEL 16 Selects left audio channel RIGHT CHANNEL CHANNEL 1 to CHANNEL 16 Selects right audio channel SOUND OUT ON OFF ON Enables audio output OFF Disables audio output LEVEL METER OFF 1 8CH 9 16CH Sets audio chan...

Страница 29: ...ION POWER OFF FUNCTION Press to select ON Note Timer function will not work unless PRESENT TIME OF DAY is set 2 1 SET UP TIMER Press to select DAY or PRESENT TIME OF DAY Press to set up DAY or PRESENT TIME OF DAY button Forward button Back Notes Pressing or button once changes PRESENT TIME OF DAY 1 minute Pressing or button continuously changes PRESENT TIME OF DAY by 15 minutes Press to select SET...

Страница 30: ...s SCREENSAVER For preventing image retention Setup of SCREENSAVER Time After selecting TIME OF DAY or INTERVAL the relevant Time Setup will become available for selection and the Operating Time may be set Time cannot be set when MODE is ON or OFF Press to select START TIME FINISH TIME When TIME OF DAY is selected Press to select SHOW DURATION SAVER DURATION When INTERVAL is selected Press to setup...

Страница 31: ...ed time the screen may become slightly darker see page 49 Reduces screen image retention SIDE BAR ADJUST 1 Press to select the SIDE BAR ADJUST Press to select OFF DARK MID BRIGHT Press to exit from SCREENSAVER 2 Do not display a picture in 4 3 mode for an extended period as this can cause an image retention to remain on the side bars on either side of the display field To reduce the risk of such a...

Страница 32: ...n or off automatically When no pictures HD VD sync signals are detected for 30 or so seconds during PC IN signal input Power is turned off standby the power indicator lights up orange When pictures HD VD sync signals are subsequently detected Power is turned on the power indicator lights up green Notes This function operates only during PC IN signal input This function is invalid during input from...

Страница 33: ...MPONENT3 RGB3 PC3 DVD3 CATV3 VCR3 STB3 PC Mini D sub input PC COMPONENT RGB DVD STB Addition sign A B Selected Input Composite S VIDEO When BNC Dual Video Terminal Board TY FB9BD is used an A or B is added at the end of each input label depending on the input selected see below Customizing the Input labels Sets the fan control and the display style of on screen menu for vertical installation Press...

Страница 34: ...I DISPLAY SETUP SET UP for MULTI DISPLAY Example group of 16 4 4 group of 4 2 2 group of 9 3 3 group of 25 5 5 Press to display the SET UP menu 1 2 3 Press to select the menu to adjust Press to adjust the menu Item Details MULTI DISPLAY SETUP Select ON or OFF Note If you set MULTI DISPLAY SETUP to ON PORTRAIT SETUP will be unavailable HORIZONTAL SCALE Select 1 2 3 4 5 VERTICAL SCALE Select 1 2 3 4...

Страница 35: ...mote ID On to operate the ID remote control If remote ID is set to On you can use the remote control without identical ID number during option menu display see page 45 The ID remote control cannot be used when ID select is set to anything other than 0 and the remote control ID is not the same as the ID select number see page 45 ID remote control button operation The operation is the same as normal...

Страница 36: ... to insert sub screen INSERT LEVEL Background image main screen Two picture insertion Onlytheareasontheoverlay image that are brighter than the INSERT LEVEL are displayedonthebackground image 10 1 Note TRANSPARENCY cannot be set when INSERT is ON Transparent Display of the Sub Screen During BLEND PIP 1 Select ON in TRANSPARENCY 2 Set the transparency level for the sub screen in TRANSPARENCY LEVEL ...

Страница 37: ...O Press to select OFF ON How to setup PORTRAIT 1 2 3 4 To hide joints between displays Suitable for moving image display To show joints between displays Suitable for still image display ON OFF 2 2 SET UP MULTI DISPLAY SETUP SET UP TIMER PRESENT TIME SETUP DISPLAY ORIENTATION LANDSCAPE MULTI PIP SETUP PORTRAIT SETUP OFF PORTRAIT SETUP SEAM HIDES VIDEO OFF 1 OFF AI SYNCHRONIZATION VIEWING AREA LOCAT...

Страница 38: ...HRONIZATION VIEWING AREA LOCATION 16 9 PORTRAIT SETUP OFF PORTRAIT SETUP SEAM HIDES VIDEO OFF 1 OFF AI SYNCHRONIZATION VIEWING AREA LOCATION 16 9 PORTRAIT SETUP 5 VIEWING AREA Set a mode of image division for PORTRAIT function LOCATION Set a location of image to be displayed for PORTRAIT function VIEWING AREA LOCATION When PORTRAIT SETUP ON Display the image of the selected LOCATION When PORTRAIT ...

Страница 39: ...display the SET UP menu Press to select the COMPONENT RGB IN SELECT Press to select the desired mode COMPONENT RGB Press to exit from adjust mode Notes Selection may not be possible depending on which optional board is installed Make setting of the selected input terminal SLOT1 SLOT2 SLOT3 or PC IN 1 2 3 YUV RGB IN SELECT Select to match the signals from the source connected to the DVI input termi...

Страница 40: ...24 60 SYNC SIGNAL H FREQ V FREQ kHz Hz 63 98 60 02 SIGNAL FORMAT 1280 1024 60 RGB 3 2 PULLDOWN XGA MODE NOISE REDUCTION OFF REFRESH RATE 100 Hz AUTO OFF 1024 768 3D Y C FILTER NTSC ON 40 Press to select the menu to adjust Press to adjust the menu Press to exit from adjust mode Note SIGNAL setup menu displays a different setting condition for each input signal 3 4 SET UP for Input Signals SIGNAL me...

Страница 41: ...1125 1080 60i signal input during COMPONENT input signal Mode Function COLOR SYSTEM Set the color system to match the input signal When selecting AUTO the color system is automatically selected from NTSC PAL SECAM however M NTSC signal is not displayed properly depending on the attached terminal board To display M NTSC signal select M NTSC in COLOR SYSTEM AUTO SECAM M NTSC NTSC PAL Panasonic AUTO ...

Страница 42: ...t be adjusted while a HD signal is being applied REFRESH RATE SET UP for Input Signals Press to select REFRESH RATE Press to adjust This function sets the refresh rate of the display This menu is displayed when the input signal is 50 Hz system 50i 50p 25p 24p 24sF of vertical scan rate 100 Hz Reduce screen flicker 50 Hz Enhance the resolution of moving images Note It is recommended to set to 100 H...

Страница 43: ...nc ON G Uses a synchronized signal on the Video G signal which is input from the G connector VBS Uses a synchronized signal of Composite Sync input which is input from the HD connector Displays the frequency and the type of the current input signal This display is valid only for COMPONENT RGB PC and Digital input signal Display range Horizontal 15 110 kHz Vertical 48 120 Hz Input signal display Pr...

Страница 44: ...hen a dual input terminal board is attached A or B is displayed depending on the selected input signal Ex INPUT1A INPUT1B Initial VOL level Press button to adjust the volume when the unit is turned on Off On Off Sets normal volume On Sets your preferred volume Notes When Maximum VOL level is On the volume can only be adjusted between 0 and your maximum range You can hear the changed volume regardl...

Страница 45: ... or after plugging off and in again Normal Power returns in as the same state as before the power interruption Standby Power returns in standby mode Power Indicator red orange On Power returns in power On Power Indicator green Note When using multiple displays Standby is preferred to be set in order to reduce a power load ID select Sets panel ID number when panel is used in Remote ID or Serial ID ...

Страница 46: ...f and in again the power cord After you unplug and plug the power cord in while the unit is in standby mode and also the power is being supplied to a terminal board the unit will start supplying the power to the board with time delay according to the setting The power indicator lights up red first and it turns orange when the power starts being supplied to the board Clock Display Off Not display t...

Страница 47: ...day timer programming by setting time and command Note Before setting Weekly Command Timer set PRESENT TIME SETUP see page 29 Press to select Function Press to select On Note When Function is set to On SET UP TIMER see page 29 is unavailable and INTERVAL TIME OF DAY in MODE of SCREENSAVER see page 30 cannot be selected 1 Press to select a day Press to select a program number Note You can set the p...

Страница 48: ... the ENTER button till the SHIPPING menu is displayed 4 Press the Volume Up or Down button to select YES 5 Press the ENTER button and wait for 10 sec Note Press the R button to return to SET UP menu when SHIPPING menu is displayed Options Adjustments Press to select Command No Press to select a command number 6 Press to select Time Command Press to set each item Time Set the time to execute a comm...

Страница 49: ...r between image and audio depending on the type of input signal However this is not a malfunction Plasma Display panel Symptoms Check The screen darkens slightly when bright pictures with minimal movements are shown The screen will darken slightly when photos still images of a computer or other pictures with minimal movements are shown for an extended period This is done to reduce image retention ...

Страница 50: ...e areas around the left and right edges of the screen is slightly elongated 4 3 4 3 Pictures with a 4 3 aspect ratio are displayed with their original aspect ratio Side panels are displayed at the left and right edges of the screen 4 3 1 4 3 2 4 3 Pictures with a 4 3 aspect ratio are displayed with their original aspect ratio The left and right edges of the pictures are masked by side panels 4 3 F...

Страница 51: ...768 70 Hz 56 48 70 07 75 0 33 1 024 768 75 Hz 60 02 75 03 78 75 34 1 024 768 85 Hz 68 68 85 00 94 5 35 1 066 600 60 Hz 37 64 59 94 53 0 53 0 36 1 152 864 60 Hz 53 70 60 00 81 62 37 1 152 864 75 Hz 67 50 75 00 108 0 38 1 280 768 60 Hz 47 70 60 00 80 14 39 1 280 960 60 Hz 60 00 60 00 108 0 40 1 280 960 85 Hz 85 94 85 00 148 5 41 1 280 1 024 60 Hz 63 98 60 02 108 0 108 0 42 1 280 1 024 75 Hz 79 98 75...

Страница 52: ...25 50p 50 00 31 25 27 00 720 864 576 625 4 750 60p 60 00 45 00 74 25 1280 1650 720 750 5 750 50p 50 00 37 50 74 25 1280 1980 720 750 6 1125 60i 60 00 33 75 74 25 1920 2200 1080 1125 7 1125 50i 50 00 28 13 74 25 1920 2640 1080 1125 8 1125 60p 60 00 67 50 148 50 1920 2200 1080 1125 9 1125 50p 50 00 56 26 148 50 1920 2640 1080 1125 10 1125 24p 24 00 27 00 74 25 1920 2750 1080 1125 VIDEO input HDMI No...

Страница 53: ...de Picture in Picture 36 DWA POP Dual Picture mode Picture out Picture 37 DWA SWP Swap main picture and sub picture when PIP mode 38 DWA TWN Dual Picture mode Picture and Picture 39 IMS PC1 Input select PC1 Main Picture when PIP mode 40 IMS SL1 Input select SLOT1 Main Picture when PIP mode 41 IMS SL1A Input select SLOT1A Main Picture when PIP mode 42 IMS SL1B Input select SLOT1B Main Picture when ...

Страница 54: ...ntal scanning frequency 15 110 kHz Vertical scanning frequency 48 120 Hz Connection terminals HDMI A B TYPE A Connector 2 COMPONENT RGB IN Y G BNC PB B BNC PR R BNC AUDIO IN RCA PIN JACK 2 with sync 1 0 Vp p 75 Ω 0 7 Vp p 75 Ω 0 5 Vrms PC IN HIGH DENSITY MINI D SUB 15PIN B PB CB R PR CR HD VD AUDIO IN M3 JACK Y or G with sync 1 0 Vp p 75 Ω Y or G without sync 0 7 Vp p 75 Ω 0 7 Vp p 75 Ω 0 7 Vp p 7...

Страница 55: ...frequency 15 110 kHz Vertical scanning frequency 48 120 Hz Connection terminals HDMI A B TYPE A Connector 2 COMPONENT RGB IN Y G BNC PB B BNC PR R BNC AUDIO IN RCA PIN JACK 2 with sync 1 0 Vp p 75 Ω 0 7 Vp p 75 Ω 0 5 Vrms PC IN HIGH DENSITY MINI D SUB 15PIN B PB CB R PR CR HD VD AUDIO IN M3 JACK Y or G with sync 1 0 Vp p 75 Ω Y or G without sync 0 7 Vp p 75 Ω 0 7 Vp p 75 Ω 0 7 Vp p 75 Ω 1 0 5 0 Vp...

Страница 56: ...s indicated above Panasonic Professional Display Company referred to as the Warrantor will repair this product and all included accessories with new or refurbished parts free of charge in the USA or Puerto Rico of the original purchase in the event of a defect in materials or workmanship as follows In the USA and Puerto Rico FOR SERVICE CALL TOLL FREE 1 800 973 4390 2 Years 2 Years On site or carr...

Страница 57: ...rage period Proof of product purchase is a condition of warranty service The owner must produce the product purchase receipt or other satisfactory evidence of date of original purchase This warranty does not apply to external appearance items such as handles knobs safety windows etc This warranty does not apply to any part or parts of the product installed altered repaired or misused in any way th...

Страница 58: ...58 ...

Страница 59: ...3 436 3500 Dallas Region 6226 Abington Way Houston TX 77008 713 802 2726 No CA Northwest Region 5870 Stone Ridge 3 Pleasanton CA 925 416 5108 Government Marketing Department 52 West Gude Drive Rockville MD 20850 301 738 3840 Panasonic Canada Inc 5770 Ambler Drive Mississauga Ontario L4W 2T3 Customer s Record The model number and serial number of this product can be found on its back cover You shou...

Отзывы: