Panasonic Videolarm POD9C Скачать руководство пользователя страница 4

- 4 -

WJ-HD316A

WU-CU650

Wiring Color Code

Power and Control Inputs

1          24 VAC Live                 Black
2          24 VAC Live                 White
3          Green                           Green
4                        Not Used          

1          24 VAC Live                  Red
2          24 VAC Live                  White
3          Green                           Green
4                        Not Used  

1          Ground                          Brown
2          TXB (RS485)                Red
3          TXA (RS485)                Orange
4          RXB (RS485)                Yellow
5          RXB (RS485)                Green

CAMERA POWER [13 watts WV-CS954 / WV-CS574]

CONNECTOR B 
ACCESSORY POWER [52 watts Heater/Blower]

CONTROL

POD9C
CONNECTOR A

Pan/Tilt Unit Only

1          Alarm In 1                     Black
2          Ground                         Brown
3          Alarm In 2                     Red
4          Ground                         Orange
5          Alarm In 3                     Yellow
6          Ground                         Light blue or green
7          Alarm In 4                     Blue
8          Ground                         Purple

ALARM IN (8-pin)

1          Alarm Out 1                  Gray
2          Ground                         White
3          Alarm Out 2                  Pink
4          Ground                         Yellow, Green, or Light blue

ALARM OUT (4-pin)

Approx. 0.1"

Wire

Insert

Up

Contact

Wire

Up

Contact

1

2

4

3

1

2

4

3

HOW TO ASSEMbLE THE CONNECTOR

•  Strip back the cable jacket approximately 0.1 inch 
(3 mm) and separate the individual conductors.

Prepare the individual conductors for clamping. If 
clamping, use Molex brand tool part number 57027-
5000 (for UL-listed-style cable UL1015) or 57026-5000 
(for UL-listed-style cable UL1007).

After  clamping  the  contacts,  push  them  into  the 
proper  holes  in  the  connector  housing  until  they 
snap in place.

CAUTIONS

•    Shrinking  the  cable-entry  seal  is  a  onetime 

procedure.  Do  not  shrink  the  cable-entry  seal 
until  it  has  been  determined  that  the  unit  is 
functioning.

•  

 CONNECT  THIS  TO  A  4  VAC  CLASS    POWER 

SUPPLY ONLY.

CAUTION

:  TO PREVENT FIRE OR SHOCK HAZARD, THE 

UL-LISTED WIRE VW-1, STYLE 1007,  SHOULD BE USED 
FOR THE CABLE FOR 24 VAC INPUT TERMINALS.

OPERATING DISTANCES

Awg Size 

Impedance 

Max Distance

Awg #12 

1.71 ohm/1000 ft. 

440 ft. 

Awg #14 

2.73 ohm/1000 ft. 

270 ft.

Awg #16 

4.35 ohm/1000 ft. 

170 ft.

Awg #18 

6.92 ohm/1000 ft. 

100 ft.

CAUTION

:  For lightning protection of the camera 

and heater/blower, the pin 3 of the connector 
must be connected to real electrical ground.

Содержание Videolarm POD9C

Страница 1: ...for Before attempting to connect or operate this product please read these instructions completely Installation Instructions Outdoor Domed Housings POD9C W POD9CF W Manufactured By 81 IN3079 6 8 05 ...

Страница 2: ... intact Failure to comply with the foregoing could result in the unit separating from the support structure and falling with resultant damages or injury to anyone or anything struck by the falling unit UNPACKING Unpackcarefully Electroniccomponentscanbedamaged ifimproperlyhandledordropped Ifanitemappearstohave been damaged in shipment replace it properly in its carton and notify the shipper Be sur...

Страница 3: ... mount bracket and close the access door Secure with the screw removed earlier 6 Clean the outside of the dome Figure 1 Access panel 3 Open the access door on the bottom of the wall mount by loosening the screw nearest the mounting plate Figure 1 1 A wall mount bracket comes standard with this unit and a template is included to use as a guide for mounting the bracket to a wall Choose the desired l...

Страница 4: ...et approximately 0 1 inch 3 mm and separate the individual conductors Prepare the individual conductors for clamping If clamping use Molex brand tool part number 57027 5000 for UL listed style cable UL1015 or 57026 5000 for UL listed style cable UL1007 After clamping the contacts push them into the proper holes in the connector housing until they snap in place CAUTIONS Shrinking the cable entry se...

Страница 5: ...his be done before installing the housing Figure 1 INSTALLATION FOR WV CS954 UNITIZED CAMERA 1 Connect the quick release bracket to the spacers using the 4 8 x 32 x 1 2 bolts and 8 star washers to the top of the spacers as shown Figure 1a 2 Attach the unitized camera to the quick release bracket Secure the safety screw Figure 2 Connect the BNC power control and alarm cables Make sure all wiring is...

Страница 6: ...ing the 1 4 20 hex bolt provided Make final adjustments and lock down the pan tilt and height adjustment screws Figure 7 Figure 4 Figure 5 Figure 7 Tilt adjustment screw 1 4 20 hex bolt NOTE A 90 BNC connector is included in the packet to assist in fitting the camera Figure 6 Figure 6 IMPORTANT NOTE Put the dome in place to assure the camera does not touch it To reattach the dome you must twist it...

Страница 7: ... RPRH708 7 Connection PCB Connection PCB Fixed Models RPFD050 Model POD9CW RPRH706 Model POD9CFW 8 Housing Hardware RPFD040 9 Housing Top RPPOD08 10 Panasonic Wall Mount PWM10 11 Captive Hardware 3 Pcs RPPOD09 Pendant Coupling Assembly Wall Mount Assembly EXPLODED VIEWS OF HOUSING Fixed Bracket Assembly 12 Quick Release Pipe Coupling SD0170 13 Pendent Housing Coupling RPPOD10 14 Pendent Mount Brac...

Страница 8: ... 2 000 3 250 R 733 2 132 2 981 1 537 5 500 Mounting Template ...

Отзывы: