68
UF-5500 / 4500
2. Safety Protection
a. 2 thermostats are provided with the unit, and the heater circuit is shut down when their surface temperatures became over
320
°
F (160
°
C).
b. The heater control circuit of IC300 has the built-in function that the hardware turns off the heater control automatically if
the software does not keep turning ON the heater every a fixed time.
c. When the temperature became over 482
°
F (250
°
C), the heater control circuit of IC300 is turned off forcedly and system
reset will be executed.
Содержание UF-5500
Страница 180: ...180 UF 5500 4500...
Страница 248: ...248 UF 5500 4500 13 5 Test Chart 13 5 1 ITU T No 1 Test Chart...
Страница 249: ...249 UF 5500 4500 13 5 2 ITU T No 2 Test Chart...
Страница 281: ...281 UF 5500 4500 10 10 11 15 12 17 18 19 20 21 22 23 24 28 29 30 27 25 26 21 13 14 16 30...
Страница 287: ...287 UF 5500 4500 130 131 132 133 134 135 136 137 138 139 140 141 PCB2 A UF 5500 only CN1...
Страница 289: ...289 UF 5500 4500 PCB8 PCB4 160 161 163 162 164 167 168 171 177 178 172 173 174 173 176 169 170 162 164 A A 165...
Страница 297: ...297 UF 5500 4500...
Страница 305: ...305 UF 5500 4500...
Страница 309: ...309 UF 5500 4500 A1 A3 A4 A6 A7 A8 A9 A10 P1 P2 P3 P4 P5 P6 P7 P8 P7 Drum Cartridge Toner Cartridge P9 A11...
Страница 311: ...311 UF 5500 4500 501 502 503 504 506 507 505 508 509 511 510 514 513 512 P51 P53 P54 A51 P52...
Страница 362: ...362 UF 5500 4500...
Страница 365: ...365 UF 5500 4500 Published in Japan...