Precautions for Use

Installation

z

z

This air conditioner must be installed properly by qualified 

installation technicians in accordance with the Installation 

Instructions provided with the unit.

z

z

Before installation, check that the voltage of the electric sup-

ply in your home or office is the same as the voltage shown 

on the nameplate.

WARNING

Avoid the following locations for installation.

z

z

Locations where smoke or combustible gas exists. 

Also locations of extremely high temperature such as a 

greenhouse.

z

z

Locations where excessively high heat-generating ob-

jects are placed.

Attention:

z

z

Avoid installing the outdoor unit where salty sea water can 

splash directly onto it or in sulphurous air near a spa. 

(To protect the air conditioner from heavy corrosion)

Wiring

z

z

All wiring must conform to the local electrical codes. 

(Consult your dealer or a qualified electrician for details.)

z

z

Each unit must be properly grounded with a ground (or 

earth) wire or through the supply wiring.

z

z

Wiring must be done by a qualified electrician.

Operation Preparation

Turn the power mains on 5 hours before  

the start of operation.

(For warm-up)

z

z

Leave the power mains ON for continuous use.

ON

NOTE

Pull off the power plug from a receptacle, or switch off the 

breaker, or switch off the power disconnecting mean to isolate 

the air conditioner from the main power supply when not in use 

for a long time.

Information for Users on Collection and Disposal of 

Old Equipment and Used Batteries

[Information on Disposal in other Countries 

outside the European Union] 

These symbols are only valid in the European 

Union. If you wish to discard these items, 

please contact your local authorities or dealer 

and ask for the correct method of disposal.

Pb

Note for the battery symbol (bottom two 

symbol examples):

This symbol might be used in combination with 

a chemical symbol. In this case it complies 

with the requirement set by the Directive for 

the chemical involved.

Operation Condition

Use this air conditioner under the following temperature range.

Outdoor Unit

Indoor 

temperature 

range

Outdoor 

temperature 

 range

3WAY (Type MF3)

Cooling 

14°C   25°C (*WBT)

-10°C   52°C (*DBT)
-10°C   43°C (*DBT)*1

Heating

16°C   30°C (*DBT) -20°C   18°C (*WBT)

Cooling & 

Heating

-10°C   24°C (*DBT)

*DBT: Dry bulb temperature

*WBT: Wet bulb temperature

*1:  The maximum allowable temperature of this air conditioning 

system is reduced to 43°C when using the existing R22 pipe.

Important Information Regarding The 

Refrigerant Used

This product contains fluorinated greenhouse gases. Do 

not vent gases into the atmosphere.
Refrigerant type: R410A
GWP

(1)

 value: 2088

(1)

GWP = global warming potential

Periodical inspections for refrigerant leaks may be 

required depending on European or local legislation. 

Please contact your local dealer for more information.

OI_300935_EN.indb   4

2018/04/25   10:27:47

Содержание U-8MF3R7

Страница 1: ...upplied with the indoor unit INDOOR UNIT 1 Way Cassette 2 Way Cassette 4 Way Cassette 4 Way Cassette 60 60 Wall Mounted Ceiling Low Silhouette Ducted Slim Low Static Ducted High Static Pressure Ducted Floor Standing Concealed Floor Standing Slim Type Ducted Panasonic Corporation 1006 Kadoma Kadoma City Osaka Japan ACXF55 19200 Before operating the unit read these operating instructions thoroughly ...

Страница 2: ... air conditioner indoor or outdoor unit rotating parts may cause injury The following symbols used in this manual alert you to potentially dangerous conditions to users service personnel or the appliance WARNING This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death CAUTION This symbol refers to a hazard or unsafe practice which can result in personal...

Страница 3: ...ep the fire alarm and the air outlet at least 1 5m away from the unit Do not cool or heat the room too much if babies or invalids are present Do not turn the air conditioner on and off from the power mains switch Use the ON OFF operation button Do not stick anything into the air outlet of the outdoor unit This is dangerous because the fan is rotating at high speed Do not touch the air inlet or the...

Страница 4: ...mean to isolate the air conditioner from the main power supply when not in use for a long time Information for Users on Collection and Disposal of Old Equipment and Used Batteries Information on Disposal in other Countries outside the European Union These symbols are only valid in the European Union If you wish to discard these items please contact your local authorities or dealer and ask for the ...

Страница 5: ...Operating Instructions attached to the indoor unit Troubleshooting Refer to the Operating Instructions attached to the indoor unit Optional For all indoor units Wireless Remote Controller Model No CZ RTC4 For all indoor units Timer Remote Controller Model No CZ RTC5B For all indoor units Read the operating instructions included with the Remote Controller High spec Wired Remote Controller Air intak...

Страница 6: ...57 0 60 0 61 0 62 0 Sound power level dB A 76 0 78 0 81 0 82 0 82 0 Unit dimensions H W D mm 1842 1180 1000 1842 1180 1000 1842 1180 1000 1842 1180 1000 1842 1180 1000 Net weight kg 264 265 289 337 337 Performance test condition AS NZS 3823 2 Rated conditions Cooling Indoor intake air temp 27 C DB 19 C WB Outdoor intake air temp 35 C DB Heating Indoor intake air temp 20 C DB Outdoor intake air tem...

Страница 7: ...7 MEMO OI_300935_EN indb 7 2018 04 25 10 27 48 ...

Страница 8: ...Panasonic Corporation Website http www panasonic com Printed in Malaysia Panasonic Corporation 2018 ACXF55 19200 DC0418 0 OI_300935_EN indb 8 2018 04 25 10 27 48 ...

Отзывы: