OPERATION CONDITION

For safety, be sure to turn the air conditioner off and also to disconnect the 
power before cleaning or servicing.

Pull off the power plug from a receptacle, or switch off the breaker, or switch 
off the power disconnecting mean to isolate the air conditioner from the 
main power supply in case of emergency.

Do not turn the air conditioner on and off from the power mains switch. Use the ON/
OFF operation button.

Do not stick anything into the air outlet of the outdoor unit. 
This is dangerous because the fan is rotating at high speed.

Do not touch the air inlet or the sharp aluminum 
fins of the outdoor unit. You may get injured.

Keep the fire alarm and the air outlet at least 
5 feet (1.5 m) away from the unit.

Do not let children play with the air conditioner.

Do not cool or heat the room too much if babies or invalids are present.

Do not sit or step on the unit. 
You may fall down accidentally.

Do not stick any object 
into the FAN CASE. 
You may be injured and 
the unit may be damaged.

The compressor may occasionally stop during thunderstorms. 
This is not a mechanical failure. The unit automatically recovers after a few minutes.

Use this air conditioner under the following temperature range.

3 way system

2 way system

Mini VRF system

* DBT: Dry bulb temperature
* WBT: Wet bulb temperature

Temperature range (°F/°C)

Indoor

Outdoor

*DBT

*WBT

*DBT

*WBT

Heating & Cooling

Max.

86/30

–/–

75/24

64/17.8

Min.

59/15

–/–

14/-10

14/-10

Cooling

Max.

90/32

77/25

115/46

–/–

Min.

64/17.8

57/14

14/-10

–/–

Heating

Max.

86/30

–/–

75/24

64/17.8

Min.

61/16

–/–

-4/-20

-4/-20

Temperature range (°F/°C)

Indoor

Outdoor

*DBT

*WBT

*DBT

*WBT

Cooling

Max.

90/32

77/25

122/50

–/–

Min.

64/17.8

57/14

14/-10

–/–

Heating

Max.

86/30

–/–

75/24

64/17.8

Min.

61/16

–/–

-4/-20

-4/-20

Temperature range (°F/°C)

Indoor

Outdoor

*DBT

*WBT

*DBT

*WBT

Cooling

Max.

90/32

77/25

115/46

–/–

Min.

64/17.8

57/14

14/-10

–/–

Heating

Max.

86/30

–/–

75/24

64/17.8

Min.

61/16

–/–

-4/-20

-4/-20

F570001_EN.fm  Page 4  Tuesday, June 23, 2015  9:25 AM

Содержание U-72ME2U9

Страница 1: ...E1U6 Indoor Unit Type Type Outdoor Units Nominal Capacity ME2 2WAY VRF System MF2 3WAY VRF System LE1 Mini VRF System Outdoor Unit Type Type 36 72 U 72ME2U9 U 72MF2U9 96 U 96ME2U9 U 96MF2U9 120 U 120ME2U9 144 U 144ME2U9 U 120MF2U9 U 144MF2U9 S 12MT2U6 S 18MT2U6 S 24MT2U6 U2 4 Way Cassette 36 x 36 S 24MU2U6 CZ 36KPU3U S 36MU2U6 CZ 36KPU3U Connectable outdoor unit lineup This booklet is the operatin...

Страница 2: ...FICATIONS 11 PRODUCT INFORMATION If you have problems or questions concerning your Air Conditioner you will need the following information Model and serial numbers are on the nameplate of the unit Model No _________________________________ Serial No _______________________ Date of purchase ______________________________________________________________ Dealer s address _____________________________...

Страница 3: ...with a ground or earth wire or through the supply wiring Wiring must be done by a qualified electrician To warm up the system the power mains must be turned on at least five 5 hours before operation Leave the power mains ON unless you will not be using this appliance for an extended period Pull off the power plug from a receptacle or switch off the breaker or switch off the power disconnecting mea...

Страница 4: ...bies or invalids are present Do not sit or step on the unit You may fall down accidentally Do not stick any object into the FAN CASE You may be injured and the unit may be damaged The compressor may occasionally stop during thunderstorms This is not a mechanical failure The unit automatically recovers after a few minutes Use this air conditioner under the following temperature range 3 way system 2...

Страница 5: ...iling Refer to the Operating Instructions attached to the optional Timer Remote Controller Refer to the Operating Instructions attached to the optional High spec Wired Remote Controller Ceiling panel optional Air intake grille air intake Water drain Air outlet 4 locations Air outlet Water drain Air intake grille air intake NOTE A CZ RTC4 NOTE CZ RTC3 CZ RTC5 ...

Страница 6: ...h your hands B Horizontal directions manual The horizontal airflow direction can be adjusted manually by moving the vertical vanes to the left or right If multiple indoor units are connected to a remote controller the airflow direction can be set for each indoor unit by selecting the indoor units see the operation below To set the airflow for individual units press the UNIT button Display shows th...

Страница 7: ...When defrosting Indoor unit fan stops When Heating Operation Started Only 3WAY VRF When changed to heating mode from stopped or cooling operation mode the unit does not work for about 3 minutes for the sake of self protection It may take about 5 to 10 minutes until the hot air is delivered after starting the heating operation Oil Recovery The indoor unit fan may stop or run at a slow speed in orde...

Страница 8: ...ide be careful not to force the vanes out of place 1 Never use solvents or harsh chemicals when cleaning the indoor unit Do not wipe plastic parts using very hot water 2 Some metal edges and the fins are sharp and may cause injury if handled improperly be especially careful when you clean these parts 3 The internal coil and other components of the outdoor unit must be cleaned every year Consult yo...

Страница 9: ...ugh operation stops Fan rotating makes operation smoothly Fan may sometimes rotate because of drying heat exchanger due to settings Wind direction changes while operating Wind direction setting cannot be made Wind direction cannot be changed When air discharge temperature is low or during defrost operation horizontal wind flow is made automatically Flap position is occasionally set up individually...

Страница 10: ... openings closed Should the power fail while the unit is running If the power supply for this unit is temporarily cut off the unit will automatically resume operation once power is restored using the same settings before the power was interrupted Symptom Cause Remedy Air conditioner does not run at all although power is turned on Power failure or after power failure Press ON OFF operation button o...

Страница 11: ... 290 13 29 32 353 W inch mm 37 13 32 950 37 13 32 950 D inch mm 37 13 32 950 37 13 32 950 Net Weight unit panel lbs kg 53 9 24 4 60 9 27 4 Model Name S 12MT2U6 S 18MT2U6 S 24MT2U6 Power Source 208 230 V 60 Hz 1PH Cooling Capacity BTU h 12 000 19 000 25 000 kW 3 5 5 6 7 3 Heating Capacity BTU h 14 000 21 000 27 000 kW 4 1 6 2 7 9 Sound Pressure Level High Medium Low dB A 36 32 30 37 33 30 39 35 33 ...

Страница 12: ...F570001 BE0515 10615 Panasonic Corporation 2015 Printed in China ...

Отзывы: